메뉴 건너뛰기




Volumn 80, Issue 1, 2007, Pages 220-225

Cupric ion release controlled by copper/low-density polyethylene nanocomposite in simulated uterine solution

Author keywords

Cluster; Cupric ion; Nanocomposite; Release; Simulated uterine solution

Indexed keywords

CUPRIC IONS; INCUBATION; SIMULATED UTERINE SOLUTION; X-RAY MICROANALYSIS;

EID: 33845960552     PISSN: 00219304     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.30587     Document Type: Article
Times cited : (17)

References (19)
  • 1
    • 0014680321 scopus 로고
    • Metallic copper as an intrauterine contraceptive adjunct to the "T" device
    • Zipper ZA, Tatum HJ, Pastene L, Medel M, Rivra M. Metallic copper as an intrauterine contraceptive adjunct to the "T" device. Am J Obstet Gynecol 1969;105:1274-1278.
    • (1969) Am J Obstet Gynecol , vol.105 , pp. 1274-1278
    • Zipper, Z.A.1    Tatum, H.J.2    Pastene, L.3    Medel, M.4    Rivra, M.5
  • 2
    • 0031081529 scopus 로고    scopus 로고
    • Characterization of corrosion products on a copper-containing intrauterine device during storage at room temperature
    • Bastidas JM, Simancas J. Characterization of corrosion products on a copper-containing intrauterine device during storage at room temperature. Biomaterials 1997;18:247-250.
    • (1997) Biomaterials , vol.18 , pp. 247-250
    • Bastidas, J.M.1    Simancas, J.2
  • 3
    • 0033843191 scopus 로고    scopus 로고
    • Copper corrosion-simulated uterine solutions
    • Bastidas JM, Mora N, Cano E. Copper corrosion-simulated uterine solutions. Contraception 2000;61:395-399.
    • (2000) Contraception , vol.61 , pp. 395-399
    • Bastidas, J.M.1    Mora, N.2    Cano, E.3
  • 4
    • 0035009332 scopus 로고    scopus 로고
    • Characterization of copper corrosion products originated in simulated uterine fluids and on packaged intrauterine devices
    • Bastidas JM, Mora N, Cano E, Polo JL. Characterization of copper corrosion products originated in simulated uterine fluids and on packaged intrauterine devices. J Mater Sci: Mater Med 2001;12:391-397.
    • (2001) J Mater Sci: Mater Med , vol.12 , pp. 391-397
    • Bastidas, J.M.1    Mora, N.2    Cano, E.3    Polo, J.L.4
  • 5
    • 0036132475 scopus 로고    scopus 로고
    • Influence of pH and oxygen on copper corrosion in simulated uterine fluid
    • Mora N, Cano E, Mora EM, Bastidas JM. Influence of pH and oxygen on copper corrosion in simulated uterine fluid. Biomaterials 2002;23:667-671.
    • (2002) Biomaterials , vol.23 , pp. 667-671
    • Mora, N.1    Cano, E.2    Mora, E.M.3    Bastidas, J.M.4
  • 6
    • 0029394789 scopus 로고
    • Uterine biology and the intrauterine device
    • Elchalal U, Abramov Y. Uterine biology and the intrauterine device. Adv Drug Delivery Rev 1995;17:151-164.
    • (1995) Adv Drug Delivery Rev , vol.17 , pp. 151-164
    • Elchalal, U.1    Abramov, Y.2
  • 7
    • 10044279357 scopus 로고
    • Comparative performance of three types of IUDs in the United States
    • Hefnawi EF, Segal SJ, editors, Amsterdam: Elsevier;
    • Jain AK. Comparative performance of three types of IUDs in the United States. In: Hefnawi EF, Segal SJ, editors. Analysis of Intrauterine Contraception. Amsterdam: Elsevier; 1975. pp 3-16.
    • (1975) Analysis of Intrauterine Contraception , pp. 3-16
    • Jain, A.K.1
  • 8
    • 0020529011 scopus 로고
    • Type of intrauterine device and the risk of pelvic inflammatory disease
    • Lee NC. Type of intrauterine device and the risk of pelvic inflammatory disease. Obstet Gynecol 1983;62:1-6.
    • (1983) Obstet Gynecol , vol.62 , pp. 1-6
    • Lee, N.C.1
  • 9
    • 0017126129 scopus 로고
    • Copper release from copper-T intrauterine devices
    • Timonen H. Copper release from copper-T intrauterine devices. Contraception 1976;14:25-38.
    • (1976) Contraception , vol.14 , pp. 25-38
    • Timonen, H.1
  • 10
    • 0016167557 scopus 로고
    • Studies on copper release from copper-T device (T-Cu200) and its influence on sperm migration in vitro
    • Zielske H, Koch UJ, Badura R, Ladeburg H. Studies on copper release from copper-T device (T-Cu200) and its influence on sperm migration in vitro. Contraception 1974;10:651-666.
    • (1974) Contraception , vol.10 , pp. 651-666
    • Zielske, H.1    Koch, U.J.2    Badura, R.3    Ladeburg, H.4
  • 11
    • 0030111585 scopus 로고    scopus 로고
    • The corrosion behavior of copper in the simulated uterine fluid
    • Zhang C, Xu N, Yang B. The corrosion behavior of copper in the simulated uterine fluid. Corros Sci 1996;38:635-641.
    • (1996) Corros Sci , vol.38 , pp. 635-641
    • Zhang, C.1    Xu, N.2    Yang, B.3
  • 12
    • 0032529013 scopus 로고    scopus 로고
    • Mechanism of sustained drug release in diffusion-controlled polymer matrix-application of percolation theory
    • Xu T, He B. Mechanism of sustained drug release in diffusion-controlled polymer matrix-application of percolation theory. Int J Pharm 1998;170:139-149.
    • (1998) Int J Pharm , vol.170 , pp. 139-149
    • Xu, T.1    He, B.2
  • 13
    • 0037151321 scopus 로고    scopus 로고
    • Laarhoven JAH, Kruft MAB, Vromans H. Effect of supersaturation and crystallization phenomena on the release properties of a controlled release device based on EVA copolymer. J Controlled Release 2002;82:309-317
    • Laarhoven JAH, Kruft MAB, Vromans H. Effect of supersaturation and crystallization phenomena on the release properties of a controlled release device based on EVA copolymer. J Controlled Release 2002;82:309-317.
  • 14
    • 10944237914 scopus 로고    scopus 로고
    • 2+ transformations of Cu and its oxides particles with different sizes in the simulated uterine solution
    • 2+ transformations of Cu and its oxides particles with different sizes in the simulated uterine solution. Corros Sci 2005;47:1039-1047.
    • (2005) Corros Sci , vol.47 , pp. 1039-1047
    • Cai, S.Z.1    Xia, X.P.2    Xie, C.S.3
  • 15
    • 10044257748 scopus 로고    scopus 로고
    • Corrosion behavior of copper/LDPE nanocomposites in simulated uterine solution
    • Cai SZ, Xia XP, Xie CS. Corrosion behavior of copper/LDPE nanocomposites in simulated uterine solution. Biomaterials 2005;26:2671-2676.
    • (2005) Biomaterials , vol.26 , pp. 2671-2676
    • Cai, S.Z.1    Xia, X.P.2    Xie, C.S.3
  • 16
    • 3342893210 scopus 로고    scopus 로고
    • The release of cupric ion in simulated uterine: New material nano-Cu/low-density polyethylene used for intrauterine devices
    • Xu T, Lei H, Cai SZ, Xia XP, Xie CS. The release of cupric ion in simulated uterine: New material nano-Cu/low-density polyethylene used for intrauterine devices. Contraception 2004;70:153-157.
    • (2004) Contraception , vol.70 , pp. 153-157
    • Xu, T.1    Lei, H.2    Cai, S.Z.3    Xia, X.P.4    Xie, C.S.5
  • 17
    • 0033298965 scopus 로고    scopus 로고
    • Structure transition comparison between theamorphous nanosize particles and coarse-grained polycrystalline of cobalt
    • Xie CS, Hu JH, Wu R, Xia H. Structure transition comparison between theamorphous nanosize particles and coarse-grained polycrystalline of cobalt. Nanostruct Mater 1999;11:1061-1066.
    • (1999) Nanostruct Mater , vol.11 , pp. 1061-1066
    • Xie, C.S.1    Hu, J.H.2    Wu, R.3    Xia, H.4
  • 18
    • 0034072298 scopus 로고    scopus 로고
    • Effect of serum albumin on corrosion of copper in simulated uterine fluid [in Chinese]
    • Zhu JJ, Xu NX, Zhang CD, Lu JF. Effect of serum albumin on corrosion of copper in simulated uterine fluid [in Chinese]. J Chin soc corros protect 2002;20:81-87.
    • (2002) J Chin soc corros protect , vol.20 , pp. 81-87
    • Zhu, J.J.1    Xu, N.X.2    Zhang, C.D.3    Lu, J.F.4
  • 19
    • 0042389574 scopus 로고    scopus 로고
    • Impact of clay microstructure and mass absorption coefficient on the quantitative mineral identification by XRD analysis
    • Ouhadi VR, Yong RN. Impact of clay microstructure and mass absorption coefficient on the quantitative mineral identification by XRD analysis. Appl Clay Sci 2003;23:141-148.
    • (2003) Appl Clay Sci , vol.23 , pp. 141-148
    • Ouhadi, V.R.1    Yong, R.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.