메뉴 건너뛰기




Volumn 74, Issue 6, 2006, Pages 483-486

Continuation rates and reasons for discontinuing TCu380A IUD use in Tabriz, Iran

Author keywords

Continuation rate; Discontinuation reasons; Intrauterine device; TCu380A IUD

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; BLEEDING; CONTRACEPTION; CONTROLLED STUDY; FEMALE; HUMAN; INTRAUTERINE CONTRACEPTIVE DEVICE; IRAN; NORMAL HUMAN; PAIN; PREGNANCY RATE; TREATMENT WITHDRAWAL;

EID: 33845945176     PISSN: 00107824     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.contraception.2006.08.007     Document Type: Article
Times cited : (8)

References (13)
  • 1
    • 0034844241 scopus 로고    scopus 로고
    • Risk factors for intrauterine device failure: a review
    • Thonneau P., Goulard H., and Goyaux N. Risk factors for intrauterine device failure: a review. Contraception 64 (2001) 33-37
    • (2001) Contraception , vol.64 , pp. 33-37
    • Thonneau, P.1    Goulard, H.2    Goyaux, N.3
  • 2
    • 0344973664 scopus 로고    scopus 로고
    • Intrauterine devices: mechanisms of action, safety and efficacy
    • Mishell D.R. Intrauterine devices: mechanisms of action, safety and efficacy. Contraception 58 (1998) S45-S53
    • (1998) Contraception , vol.58
    • Mishell, D.R.1
  • 3
    • 33845929275 scopus 로고    scopus 로고
    • Ministry of Health and Medical Education-Bureau of Population and Family Health, Population and Health in the Islamic Republic of Iran-DHS, October 2000 Tehran: the Ministry of Health and Medical education and the United Nations Children's Fund (UNICEF); 2000. p. 64.
  • 5
    • 0026554516 scopus 로고
    • Should collared CuT intrauterine devices be replaced before eight years?
    • Sivin I. Should collared CuT intrauterine devices be replaced before eight years?. Br J Fam Plann 18 (1992) 9-11
    • (1992) Br J Fam Plann , vol.18 , pp. 9-11
    • Sivin, I.1
  • 6
    • 33845923198 scopus 로고
    • Management of common genital infections
    • Efficacy and failure rate of IUD. Management of common genital infections. IPPF Med Bull 28 5 (1994) 4
    • (1994) IPPF Med Bull , vol.28 , Issue.5 , pp. 4
    • Efficacy and failure rate of IUD1
  • 7
    • 0035991008 scopus 로고    scopus 로고
    • Current opinion consensus statement on intrauterine contraception
    • Rivera R., and Best K. Current opinion consensus statement on intrauterine contraception. Contraception 65 (2002) 385-388
    • (2002) Contraception , vol.65 , pp. 385-388
    • Rivera, R.1    Best, K.2
  • 8
    • 0031649492 scopus 로고    scopus 로고
    • Twelve-month comparative multicenter study of the TCU 380A and ML 250 intrauterine devices in Bangkok, Thailand
    • Reinprayoon D., Gilmore C., Farr G., and Amatya R. Twelve-month comparative multicenter study of the TCU 380A and ML 250 intrauterine devices in Bangkok, Thailand. Contraception 58 (1998) 201-206
    • (1998) Contraception , vol.58 , pp. 201-206
    • Reinprayoon, D.1    Gilmore, C.2    Farr, G.3    Amatya, R.4
  • 9
    • 0035306070 scopus 로고    scopus 로고
    • Post-marketing surveillance of Norplant contraceptive implants: contraceptive efficacy and reproductive health
    • Meirik O., Farley M.M., Sivin I., and Diaz S. Post-marketing surveillance of Norplant contraceptive implants: contraceptive efficacy and reproductive health. Contraception 63 (2001) 167-186
    • (2001) Contraception , vol.63 , pp. 167-186
    • Meirik, O.1    Farley, M.M.2    Sivin, I.3    Diaz, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.