메뉴 건너뛰기




Volumn 38, Issue 2, 2007, Pages 206-211

Percutaneous insertion of a proximal humeral locking plate: An anatomic study

Author keywords

Adult; Axillary nerve; Fracture; Geriatric; Minimally invasive; Osteoporotic; Proximal humerus; Surgery

Indexed keywords

ARTICLE; BONE PLATE; BONE SCREW; CADAVER; FEASIBILITY STUDY; HUMAN; HUMAN TISSUE; HUMERUS; NERVE COMPRESSION; PRIORITY JOURNAL; RISK ASSESSMENT; SURGICAL APPROACH; SURGICAL TECHNIQUE;

EID: 33845918500     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.injury.2006.08.025     Document Type: Article
Times cited : (63)

References (15)
  • 3
    • 18144397507 scopus 로고    scopus 로고
    • The extended anterolateral acromial approach allows minimally invasive access to the proximal humerus
    • Gardner M.J., Griffith M.H., Dines J.S., et al. The extended anterolateral acromial approach allows minimally invasive access to the proximal humerus. Clin Orthop Relat Res (2005) 123-129
    • (2005) Clin Orthop Relat Res , pp. 123-129
    • Gardner, M.J.1    Griffith, M.H.2    Dines, J.S.3
  • 4
    • 0033767296 scopus 로고    scopus 로고
    • Osteoporotic fractures of the proximal humerus in elderly Finnish persons: sharp increase in 1970-1998 and alarming projections for the new millennium
    • Kannus P., Palvanen M., Niemi S., et al. Osteoporotic fractures of the proximal humerus in elderly Finnish persons: sharp increase in 1970-1998 and alarming projections for the new millennium. Acta Orthop Scand 71 (2000) 465-470
    • (2000) Acta Orthop Scand , vol.71 , pp. 465-470
    • Kannus, P.1    Palvanen, M.2    Niemi, S.3
  • 5
    • 0030004494 scopus 로고    scopus 로고
    • Surgical neck fractures of the proximal humerus: a laboratory evaluation of ten fixation techniques
    • Koval K.J., Blair B., Takei R., et al. Surgical neck fractures of the proximal humerus: a laboratory evaluation of ten fixation techniques. J Trauma 40 (1996) 778-783
    • (1996) J Trauma , vol.40 , pp. 778-783
    • Koval, K.J.1    Blair, B.2    Takei, R.3
  • 6
    • 0031020742 scopus 로고    scopus 로고
    • Functional outcome after minimally displaced fractures of the proximal part of the humerus
    • Koval K.J., Gallagher M.A., Marsicano J.G., et al. Functional outcome after minimally displaced fractures of the proximal part of the humerus. J Bone Joint Surg Am 79 (1997) 203-207
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 203-207
    • Koval, K.J.1    Gallagher, M.A.2    Marsicano, J.G.3
  • 7
    • 0023028459 scopus 로고
    • Plate fixation of proximal humeral fractures
    • Kristiansen B., and Christensen S.W. Plate fixation of proximal humeral fractures. Acta Orthop Scand 57 (1986) 320-323
    • (1986) Acta Orthop Scand , vol.57 , pp. 320-323
    • Kristiansen, B.1    Christensen, S.W.2
  • 8
    • 1542289158 scopus 로고    scopus 로고
    • The angle stable locking-proximal-humerus-plate (LPHP) for proximal humeral fractures using a small anterior-lateral-deltoid-splitting-approach-technique and first results
    • Lill H., Hepp P., Rose T., et al. The angle stable locking-proximal-humerus-plate (LPHP) for proximal humeral fractures using a small anterior-lateral-deltoid-splitting-approach-technique and first results. Zentralbl Chir 129 (2004) 43-48
    • (2004) Zentralbl Chir , vol.129 , pp. 43-48
    • Lill, H.1    Hepp, P.2    Rose, T.3
  • 9
    • 0024327219 scopus 로고
    • Anatomy of the axillary nerve and its relation to inferior capsular shift
    • Loomer R., and Graham B. Anatomy of the axillary nerve and its relation to inferior capsular shift. Clin Orthop Relat Res (1989) 100-105
    • (1989) Clin Orthop Relat Res , pp. 100-105
    • Loomer, R.1    Graham, B.2
  • 10
    • 0030712396 scopus 로고    scopus 로고
    • Percutaneous pinning of proximal humerus fractures: a biomechanical study
    • Naidu S.H., Bixler B., Capo J.T., et al. Percutaneous pinning of proximal humerus fractures: a biomechanical study. Orthopedics 20 (1997) 1073-1076
    • (1997) Orthopedics , vol.20 , pp. 1073-1076
    • Naidu, S.H.1    Bixler, B.2    Capo, J.T.3
  • 11
    • 0026725471 scopus 로고
    • The risk of injury to the axillary nerve, artery, and vein from proximal locking screws of humeral intramedullary nails
    • Riemer B.L., and D'Ambrosia R. The risk of injury to the axillary nerve, artery, and vein from proximal locking screws of humeral intramedullary nails. Orthopedics 15 (1992) 697-699
    • (1992) Orthopedics , vol.15 , pp. 697-699
    • Riemer, B.L.1    D'Ambrosia, R.2
  • 12
    • 0035187159 scopus 로고    scopus 로고
    • Percutaneous pinning of the proximal part of the humerus. An anatomic study
    • Rowles D.J., and McGrory J.E. Percutaneous pinning of the proximal part of the humerus. An anatomic study. J Bone Joint Surg Am 83-A (2001) 1695-1699
    • (2001) J Bone Joint Surg Am , vol.83 -A , pp. 1695-1699
    • Rowles, D.J.1    McGrory, J.E.2
  • 13
    • 0033629482 scopus 로고    scopus 로고
    • Fixation of three-part proximal humeral fractures: a biomechanical evaluation
    • Ruch D.S., Glisson R.R., Marr A.W., et al. Fixation of three-part proximal humeral fractures: a biomechanical evaluation. J Orthop Trauma 14 (2000) 36-40
    • (2000) J Orthop Trauma , vol.14 , pp. 36-40
    • Ruch, D.S.1    Glisson, R.R.2    Marr, A.W.3
  • 14
    • 0020420801 scopus 로고
    • Results of surgical treatment of multifragmented fractures of the humeral head
    • Sturzenegger M., Fornaro E., and Jakob R.P. Results of surgical treatment of multifragmented fractures of the humeral head. Arch Orthop Trauma Surg 100 (1982) 249-259
    • (1982) Arch Orthop Trauma Surg , vol.100 , pp. 249-259
    • Sturzenegger, M.1    Fornaro, E.2    Jakob, R.P.3
  • 15
    • 33845917074 scopus 로고    scopus 로고
    • Walsh S, Reindl R, Harvey E, Berry G, Beckman L, Steffen T. Biomechanical comparison of the unique plate versus standard plate for internal fixation of proximal humerus fractures in a cadaveric model. Podium presentation. Canadian Orthopedic Association Annual Meeting; 2004.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.