메뉴 건너뛰기




Volumn 2005, Issue , 2005, Pages 401-404

A statistical method of improving the resolution of time-delay of UHF signals for PD location in transformers

Author keywords

[No Author keywords available]

Indexed keywords

DELAY CIRCUITS; ELECTRIC TRANSFORMERS; SIGNAL PROCESSING; UHF DEVICES;

EID: 33845911709     PISSN: 00849162     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CEIDP.2005.1560705     Document Type: Conference Paper
Times cited : (6)

References (7)
  • 1
    • 0036817485 scopus 로고    scopus 로고
    • Partial discharges: Their mechanism, detection and measurement
    • R Bartnikas, Partial discharges: Their mechanism, detection and measurement. IEEE Trans. On DEI, vol.9, no.5, 2002:763-808
    • (2002) IEEE Trans. on DEI , vol.9 , Issue.5 , pp. 763-808
    • Bartnikas, R.1
  • 2
    • 0029405006 scopus 로고
    • Partial discharge XXI: Acoustic emission - Based PD source location in transformers [J]
    • Peter E M. Partial discharge XXI: Acoustic emission - based PD source location in transformers [J]. IEEE Electrical Insulation Magazine, 1995, 11(6): 22 - 26.
    • (1995) IEEE Electrical Insulation Magazine , vol.11 , Issue.6 , pp. 22-26
    • Peter, E.M.1
  • 3
    • 33646131044 scopus 로고    scopus 로고
    • Research on locating partial discharge sources in transformer with electric-supersonic method and supersonic-supersonic method and evaluation on each
    • 10, 60
    • Sun Caixin, LuoBing, et al, Research on Locating Partial Discharge Sources in Transformer with Electric-supersonic Method and Supersonic-supersonic Method and Evaluation on Each, Transactions of China Electrotechnical Society, vol.12(5), 1997.10:49-52, 60
    • (1997) Transactions of China Electrotechnical Society , vol.12 , Issue.5 , pp. 49-52
    • Caixin, S.1    LuoBing2
  • 4
    • 0015774695 scopus 로고
    • Detection and location of partial discharge in power transformer [C]
    • Conf. Publications No. 94, Part1, March 6 - 8, London
    • Thoeng A T. Detection and location of partial discharge in power transformer [C]. Conf. Publications No. 94, Part1, IEE Diagnostic Testing of HV Power Apparatus in service, March 6 - 8, 1973, London.
    • (1973) IEE Diagnostic Testing of HV Power Apparatus in Service
    • Thoeng, A.T.1
  • 5
    • 0027810749 scopus 로고
    • Detection and location of internal defects in the insulation of power transformers [J]
    • Fuhr J, Haessig M, Boss P, et al. Detection and location of internal defects in the insulation of power transformers [J]. IEEE Trans. on EI, 1993, 28(6): 1057-1067.
    • (1993) IEEE Trans. on EI , vol.28 , Issue.6 , pp. 1057-1067
    • Fuhr, J.1    Haessig, M.2    Boss, P.3
  • 6
    • 0024717933 scopus 로고
    • Application of digital filtering techniques to determination of partial discharge location in transformers [J]
    • James R E, Phung B T, Su Q. Application of digital filtering techniques to determination of partial discharge location in transformers [J]. IEEE Trans. on EI, 1989, 24 (4): 657 - 668.
    • (1989) IEEE Trans. on EI , vol.24 , Issue.4 , pp. 657-668
    • James, R.E.1    Phung, B.T.2    Su, Q.3
  • 7
    • 17644404259 scopus 로고    scopus 로고
    • The feasibility of locating PD source in transformer using the UHF technology
    • Boulder, Colorado, USA, Oct 17-20
    • Z.G.Tang, C.R.Li, et al, The feasibility of locating PD source in transformer using the UHF technology, 2004 CEIDP, Boulder, Colorado, USA, Oct 17-20
    • 2004 CEIDP
    • Tang, Z.G.1    Li, C.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.