메뉴 건너뛰기




Volumn 30, Issue 2, 2006, Pages 97-105

Determination of the trace refractory elements V, Nb and Ta in environmental samples by ICP-MS after separation and preconcentration with nanometre-sized alumina microcolumns following chemical modification by gallic acid

Author keywords

Environmental samples; Gallic acid; Inductively coupled plasma mass spectrometry; Nanometre sized alumina; Nb; Solid phase extraction; Ta; V

Indexed keywords


EID: 33845890559     PISSN: 16394488     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1751-908x.2006.tb00916.x     Document Type: Article
Times cited : (8)

References (24)
  • 1
    • 0037069252 scopus 로고    scopus 로고
    • Liquid-liquid extraction separation recovery and transport of tantalum by crown-ether
    • Agrawal Y.K. (2002) Liquid-liquid extraction separation recovery and transport of tantalum by crown-ether. Talanta, 58, 875-882.
    • (2002) Talanta , vol.58 , pp. 875-882
    • Agrawal, Y.K.1
  • 3
    • 0036535209 scopus 로고    scopus 로고
    • Speciation of lead in environmental waters by preconcentration on a new fullerene derivative
    • Baena J.R., Gallego M. and Valcarcel M. (2000) Speciation of lead in environmental waters by preconcentration on a new fullerene derivative. Analytical Chemistry, 72, 1519-1524.
    • (2000) Analytical Chemistry , vol.72 , pp. 1519-1524
    • Baena, J.R.1    Gallego, M.2    Valcarcel, M.3
  • 4
    • 0038784768 scopus 로고    scopus 로고
    • Solid phase extraction of trace elements
    • Camel V. (2003) Solid phase extraction of trace elements. Spectrochimica Acta Part B, 58, 1177-1233.
    • (2003) Spectrochimica Acta Part B , vol.58 , pp. 1177-1233
    • Camel, V.1
  • 5
    • 0028829148 scopus 로고
    • On-line ion-exchange separation and determination of niobium, tantalum, tungsten, zirconium and hafnium in high purity iron by flow injection inductively coupled plasma-mass spectrometry
    • Coedo A.G., López T.D. and Alguacil F. (1995) On-line ion-exchange separation and determination of niobium, tantalum, tungsten, zirconium and hafnium in high purity iron by flow injection inductively coupled plasma-mass spectrometry. Analytica Chimica Acta, 315, 331-338.
    • (1995) Analytica Chimica Acta , vol.315 , pp. 331-338
    • Coedo, A.G.1    López, T.D.2    Alguacil, F.3
  • 6
    • 0026771362 scopus 로고
    • Comparison of alkyl-bonded alumina stationary phases for peptide separations by high-performance liquid chromatography
    • Haky J.E., Ramdial N.D., Dunn B.M. and Wieserman L.F. (1992) Comparison of alkyl-bonded alumina stationary phases for peptide separations by high-performance liquid chromatography. Journal of Liquid Chromatography, 15, 1831-1852.
    • (1992) Journal of Liquid Chromatography , vol.15 , pp. 1831-1852
    • Haky, J.E.1    Ramdial, N.D.2    Dunn, B.M.3    Wieserman, L.F.4
  • 7
    • 0025305830 scopus 로고
    • Comparison of octadecyl-bonded alumina and silica for reversed-phase high-performance liquid chromatography
    • Haky J.E., Vemulapalli S. and Wieserman L.F. (1990) Comparison of octadecyl-bonded alumina and silica for reversed-phase high-performance liquid chromatography. Journal of Chromatography, 505, 307-318.
    • (1990) Journal of Chromatography , vol.505 , pp. 307-318
    • Haky, J.E.1    Vemulapalli, S.2    Wieserman, L.F.3
  • 8
    • 0034962707 scopus 로고    scopus 로고
    • The kinetics and mechanisms of the reaction of iron(III) with gallic acid, gallic acid methyl ester and catechin
    • Hynes M.J. and Coinceanainn M.Ó. (2001) The kinetics and mechanisms of the reaction of iron(III) with gallic acid, gallic acid methyl ester and catechin. Journal of Inorganic Biochemistry 85, 131-142.
    • (2001) Journal of Inorganic Biochemistry , vol.85 , pp. 131-142
    • Hynes, M.J.1    Coinceanainn, M.Ó.2
  • 9
    • 0036599773 scopus 로고    scopus 로고
    • Determination of Ti, V, Zr, Nb, Mo and Ta in high-purity iron using cupferron co-precipitation separation by axially viewed ICP-AES with ultrasonic nebulization system and a long torch
    • Ide K. and Nakamura Y. (2002) Determination of Ti, V, Zr, Nb, Mo and Ta in high-purity iron using cupferron co-precipitation separation by axially viewed ICP-AES with ultrasonic nebulization system and a long torch. Materials Transactions, 43, 1409-1414.
    • (2002) Materials Transactions , vol.43 , pp. 1409-1414
    • Ide, K.1    Nakamura, Y.2
  • 10
    • 0035185905 scopus 로고    scopus 로고
    • Spectrophotometric determination of niobium(V) with N-cinnamoyl-N-2,3- xylylhydroxylamine and thiocyanate
    • Inoue S., Mishima O., Zhang Q.B., Minami H. and Uto M. (2001) Spectrophotometric determination of niobium(V) with N-cinnamoyl-N-2,3- xylylhydroxylamine and thiocyanate. Analytical Letters, 34, 2465-2475.
    • (2001) Analytical Letters , vol.34 , pp. 2465-2475
    • Inoue, S.1    Mishima, O.2    Zhang, Q.B.3    Minami, H.4    Uto, M.5
  • 11
    • 2142642204 scopus 로고    scopus 로고
    • Separation and simultaneous determination of niobium and tantalum in steel by reversed-phase high-performance liquid chromatography using 2-(2-pyridylazo)-5-diethylamino phenol as a pre-column derivatizing reagent
    • Li D.L., Hu X.Y. and Wang H.Z. (2004) Separation and simultaneous determination of niobium and tantalum in steel by reversed-phase high-performance liquid chromatography using 2-(2-pyridylazo)-5-diethylamino phenol as a pre-column derivatizing reagent. Talanta, 63, 233-237
    • (2004) Talanta , vol.63 , pp. 233-237
    • Li, D.L.1    Hu, X.Y.2    Wang, H.Z.3
  • 13
    • 0035833560 scopus 로고    scopus 로고
    • Nanometer-size titanium dioxide microcolumn on-line preconcentration of trace metals and their determination by inductively coupled plasma-atomic emission spectrometry in water
    • Liang P., Qin Y.C., Hu B., Peng T.Y. and Jiang Z.C. (2001) Nanometer-size titanium dioxide microcolumn on-line preconcentration of trace metals and their determination by inductively coupled plasma-atomic emission spectrometry in water. Analytica Chimica Acta, 440, 207-213.
    • (2001) Analytica Chimica Acta , vol.440 , pp. 207-213
    • Liang, P.1    Qin, Y.C.2    Hu, B.3    Peng, T.Y.4    Jiang, Z.C.5
  • 14
    • 0141621119 scopus 로고    scopus 로고
    • Speciation of Cr(III) and Cr(VI) by nanometer titanium dioxide micro-column and inductively coupled plasma-atomic emission spectrometry
    • Liang P., Shi T.Q., Lu H.B., Jiang Z.C. and Hu B. (2003) Speciation of Cr(III) and Cr(VI) by nanometer titanium dioxide micro-column and inductively coupled plasma-atomic emission spectrometry. Spectrochimica Acta Part B, 58, 1709-1714.
    • (2003) Spectrochimica Acta Part B , vol.58 , pp. 1709-1714
    • Liang, P.1    Shi, T.Q.2    Lu, H.B.3    Jiang, Z.C.4    Hu, B.5
  • 15
    • 0030372877 scopus 로고    scopus 로고
    • Lead preconcentration onto C-18 minicolumn in continuous flow and its determination in biological and vegetable samples by flame atomic-absorption spectrometry
    • Lima R., Leandro K.C. and Santelli R.E. (1996) Lead preconcentration onto C-18 minicolumn in continuous flow and its determination in biological and vegetable samples by flame atomic-absorption spectrometry. Talanta, 43, 977-983.
    • (1996) Talanta , vol.43 , pp. 977-983
    • Lima, R.1    Leandro, K.C.2    Santelli, R.E.3
  • 16
    • 0035850572 scopus 로고    scopus 로고
    • Separation of niobium(V) and tantalum(V) by capillary electrophoresis with chemiluminescence detection
    • Liu E.B., Liu Y.M. and Cheng J.K. (2001) Separation of niobium(V) and tantalum(V) by capillary electrophoresis with chemiluminescence detection. Analytica Chimica Acta, 443, 101-105.
    • (2001) Analytica Chimica Acta , vol.443 , pp. 101-105
    • Liu, E.B.1    Liu, Y.M.2    Cheng, J.K.3
  • 17
    • 5444220463 scopus 로고    scopus 로고
    • Spectrophotometric determination of simultaneously present niobium and tantalum
    • Nagiev K.D. (2004) Spectrophotometric determination of simultaneously present niobium and tantalum. Journal of Analytical Chemistry, 59, 930-934.
    • (2004) Journal of Analytical Chemistry , vol.59 , pp. 930-934
    • Nagiev, K.D.1
  • 18
    • 0035884164 scopus 로고    scopus 로고
    • Nonaqueous catalytic fluorometric trace determination of vanadium based on the pyronine B-hydrogen peroxide reaction and flow injection after cloud point extraction
    • Paleologos E.K., Koupparis M.A., Karayannis M.I. and Veltsistas P.G. (2001) Nonaqueous catalytic fluorometric trace determination of vanadium based on the pyronine B-hydrogen peroxide reaction and flow injection after cloud point extraction. Analytical Chemistry, 73, 4428-4433.
    • (2001) Analytical Chemistry , vol.73 , pp. 4428-4433
    • Paleologos, E.K.1    Koupparis, M.A.2    Karayannis, M.I.3    Veltsistas, P.G.4
  • 19
    • 0038660224 scopus 로고    scopus 로고
    • Trends in preconcentration procedures for metal determination using atomic spectrometry techniques
    • Pereira M.D. and Arruda M.A.Z. (2003) Trends in preconcentration procedures for metal determination using atomic spectrometry techniques. Microchimica Acta, 141, 115-131.
    • (2003) Microchimica Acta , vol.141 , pp. 115-131
    • Pereira, M.D.1    Arruda, M.A.Z.2
  • 20
    • 11344295474 scopus 로고    scopus 로고
    • Solid-phase extraction for preconcentration and separation of vanadium species in natural waters
    • Pyrzynska K. and Wierzbicki T. (2004) Solid-phase extraction for preconcentration and separation of vanadium species in natural waters. Microchimica Acta, 147, 59-64.
    • (2004) Microchimica Acta , vol.147 , pp. 59-64
    • Pyrzynska, K.1    Wierzbicki, T.2
  • 21
    • 0032812910 scopus 로고    scopus 로고
    • Determination of niobium(V) and tantalum(V) as 4-(2-pyridylazo) resorcinol-citrate ternary complexes in geological materials by ion-interaction reversed-phase high-performance liquid chromatography
    • Vachirapatama N., Macka M., Paull B., Münker C. and Haddad P.R. (1999) Determination of niobium(V) and tantalum(V) as 4-(2-pyridylazo) resorcinol-citrate ternary complexes in geological materials by ion-interaction reversed-phase high-performance liquid chromatography. Journal of Chromatography A, 850, 257-268.
    • (1999) Journal of Chromatography A , vol.850 , pp. 257-268
    • Vachirapatama, N.1    Macka, M.2    Paull, B.3    Münker, C.4    Haddad, P.R.5
  • 22
    • 0000289870 scopus 로고    scopus 로고
    • Studies on simultaneous fluorescence-spectrophotometric determination of ultratrace niobium(V), tantalum(V), and zirconium(IV) using partial least-squares algorithm
    • Wang Z.P., Qian Y.H., Chen G.S. and Cheng K.L. (1998) Studies on simultaneous fluorescence-spectrophotometric determination of ultratrace niobium(V), tantalum(V), and zirconium(IV) using partial least-squares algorithm. Microchemical Journal, 60, 271-281.
    • (1998) Microchemical Journal , vol.60 , pp. 271-281
    • Wang, Z.P.1    Qian, Y.H.2    Chen, G.S.3    Cheng, K.L.4
  • 23
    • 0035213801 scopus 로고    scopus 로고
    • A novel solid-phase extraction scheme for the group separation of high field strength elements (Nb, Ta, Zr, Hf) from Al-, Ti-, and Fe-rich geological materials
    • Yang X.J. and Pin C. (2001) A novel solid-phase extraction scheme for the group separation of high field strength elements (Nb, Ta, Zr, Hf) from Al-, Ti-, and Fe-rich geological materials. Separation Science and Technology, 36, 571-585.
    • (2001) Separation Science and Technology , vol.36 , pp. 571-585
    • Yang, X.J.1    Pin, C.2
  • 24
    • 18844415874 scopus 로고    scopus 로고
    • Simultaneous on-line preconcentration and determination of trace metals in environmental samples by flow injection combined with inductively coupled plasma-mass spectrometry using a nanometer-sized alumina packed micro-column
    • Yin J., Jiang Z.C., Chang G. and Hu B. (2005) Simultaneous on-line preconcentration and determination of trace metals in environmental samples by flow injection combined with inductively coupled plasma-mass spectrometry using a nanometer-sized alumina packed micro-column. Analytica Chimica Acta, 540, 333-339.
    • (2005) Analytica Chimica Acta , vol.540 , pp. 333-339
    • Yin, J.1    Jiang, Z.C.2    Chang, G.3    Hu, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.