메뉴 건너뛰기




Volumn 32, Issue 1, 2007, Pages 60-66

Reconstruction of the digital flexor pulley system: A retrospective comparison of two methods of treatment

Author keywords

bowstringing; extensor retinaculum graft; finger pulley reconstruction; finger pulley rupture

Indexed keywords

ADULT; ARTICLE; CONSERVATIVE TREATMENT; CONTROLLED STUDY; FEMALE; FINGER; FINGER PULLEY RUPTURE; FLEXOR TENDON INJURY; FOLLOW UP; GRIP STRENGTH; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; PROXIMAL INTERPHALANGEAL JOINT; RETROSPECTIVE STUDY; SCORING SYSTEM; TENDON GRAFT; TENDON SURGERY;

EID: 33845881711     PISSN: 17531934     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhsb.2006.09.019     Document Type: Article
Times cited : (43)

References (23)
  • 1
    • 0032873266 scopus 로고    scopus 로고
    • Diagnosis of digital flexor tendon annular pulley disruption: comparison of high frequency ultrasound and MRI
    • Bodner G Rudisch A Gabl M Judmaier W Springer P Klauser A Diagnosis of digital flexor tendon annular pulley disruption: comparison of high frequency ultrasound and MRI Ultraschall in Medicine 1999 20 131 136
    • (1999) Ultraschall in Medicine , vol.20 , pp. 131-136
    • Bodner, G.1    Rudisch, A.2    Gabl, M.3    Judmaier, W.4    Springer, P.5    Klauser, A.6
  • 3
    • 0025183031 scopus 로고
    • Injury to the A2 pulley in rock climbers
    • Bollen SR Injury to the A2 pulley in rock climbers Journal of Hand Surgery 1990b 15B 268 270
    • (1990) Journal of Hand Surgery , vol.15B , pp. 268-270
    • Bollen, S.R.1
  • 5
    • 0017222338 scopus 로고
    • Evaluation criteria in follow-up studies of flexor tendon therapy
    • Buck Gramcko D Dietrich FE Gögge S Evaluation criteria in follow-up studies of flexor tendon therapy Handchirurgie 1976 8 65 69
    • (1976) Handchirurgie , vol.8 , pp. 65-69
    • Buck Gramcko, D.1    Dietrich, F.E.2    Gögge, S.3
  • 7
    • 84992891681 scopus 로고
    • Anatomy of the flexor tendon sheath and pulley system: a current review
    • Doyle JR Anatomy of the flexor tendon sheath and pulley system: a current review Journal of Hand Surgery 1989 23A 653 657
    • (1989) Journal of Hand Surgery , vol.23A , pp. 653-657
    • Doyle, J.R.1
  • 9
    • 0034020517 scopus 로고    scopus 로고
    • The use of a graft from the second extensor compartment to reconstruct the A2 Flexor pulley in the long finger
    • Gabl M Reinhart C Lutz M Bodner G Angermann P Pechlaner S The use of a graft from the second extensor compartment to reconstruct the A2 Flexor pulley in the long finger Journal of Hand Surgery 2000 25B 98 101
    • (2000) Journal of Hand Surgery , vol.25B , pp. 98-101
    • Gabl, M.1    Reinhart, C.2    Lutz, M.3    Bodner, G.4    Angermann, P.5    Pechlaner, S.6
  • 10
    • 0021746262 scopus 로고
    • The “belt loop” technique for reconstruction of pulleys in the first stage of Flexor tendon grafting
    • Karev A The “belt loop” technique for reconstruction of pulleys in the first stage of Flexor tendon grafting Journal of Hand Surgery 1984 9A 923 924
    • (1984) Journal of Hand Surgery , vol.9A , pp. 923-924
    • Karev, A.1
  • 11
    • 0036189617 scopus 로고    scopus 로고
    • Finger pulley injuries in extreme rock climbers: Depiction with dynamic US
    • Klauser A Frauscher F Bodner G Finger pulley injuries in extreme rock climbers: Depiction with dynamic US Radiology 2002 222 755 761
    • (2002) Radiology , vol.222 , pp. 755-761
    • Klauser, A.1    Frauscher, F.2    Bodner, G.3
  • 12
    • 0017968181 scopus 로고
    • Digital pulley reconstruction employing the always present rim of the previous pulley
    • Kleinert HE Bennett JB Digital pulley reconstruction employing the always present rim of the previous pulley Journal of Hand Surgery 1978 3B 297 298
    • (1978) Journal of Hand Surgery , vol.3B , pp. 297-298
    • Kleinert, H.E.1    Bennett, J.B.2
  • 14
    • 0018600674 scopus 로고
    • Reconstruction of pulleys employing extensor retinaculum
    • Lister GD Reconstruction of pulleys employing extensor retinaculum Journal of Hand Surgery 1979 4B 461 464
    • (1979) Journal of Hand Surgery , vol.4B , pp. 461-464
    • Lister, G.D.1
  • 15
    • 0017641994 scopus 로고
    • Strength of human pulleys
    • Manske PR Lesker P Strength of human pulleys The Hand 1977 9 147 152
    • (1977) The Hand , vol.9 , pp. 147-152
    • Manske, P.R.1    Lesker, P.2
  • 16
    • 0029795903 scopus 로고    scopus 로고
    • The direct midlateral approach with lateral enlargement of the Pulley system for repair of the flexor tendons in fingers
    • Messina A Messina JC The direct midlateral approach with lateral enlargement of the Pulley system for repair of the flexor tendons in fingers Journal of Hand Surgery 1996 21B 463 468
    • (1996) Journal of Hand Surgery , vol.21B , pp. 463-468
    • Messina, A.1    Messina, J.C.2
  • 18
    • 0037309427 scopus 로고    scopus 로고
    • Flexor tendon pulley system: anatomy, pathology, treatment
    • Moutet F Flexor tendon pulley system: anatomy, pathology, treatment Chirurgie de la Main 2003 22 1 12
    • (2003) Chirurgie de la Main , vol.22 , pp. 1-12
    • Moutet, F.1
  • 19
    • 0032467407 scopus 로고    scopus 로고
    • Flexor tendon–pulley interaction after pulley reconstruction: a biomechanical study in a human model in vitro
    • Nishida J Amadio PC Bettinger PC An KN Flexor tendon–pulley interaction after pulley reconstruction: a biomechanical study in a human model in vitro Journal of Hand Surgery 1998 23B 665 672
    • (1998) Journal of Hand Surgery , vol.23B , pp. 665-672
    • Nishida, J.1    Amadio, P.C.2    Bettinger, P.C.3    An, K.N.4
  • 23
    • 0024425225 scopus 로고
    • A mechanical study of six digital pulley reconstruction techniques. Part I. Mechanical effectiveness
    • Widstrom CJ Johnson G Doyle JR Manske PR Inhofe P A mechanical study of six digital pulley reconstruction techniques. Part I. Mechanical effectiveness Journal of Hand Surgery 1989 14A 821 825
    • (1989) Journal of Hand Surgery , vol.14A , pp. 821-825
    • Widstrom, C.J.1    Johnson, G.2    Doyle, J.R.3    Manske, P.R.4    Inhofe, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.