메뉴 건너뛰기




Volumn 54, Issue 9, 2006, Pages 45-52

New compact scrubber for odour removal in wastewater treatment plants

Author keywords

Chemical scrubbing; Hydrogen sulphide; Methylmercaptan; Odour removal

Indexed keywords

CHEMICAL REACTORS; DESULFURIZATION; HYDROGEN SULFIDE REMOVAL (WATER TREATMENT); ODOR REMOVAL; WASTEWATER TREATMENT; WATER TREATMENT PLANTS;

EID: 33845874676     PISSN: 02731223     EISSN: None     Source Type: Book Series    
DOI: 10.2166/wst.2006.862     Document Type: Article
Times cited : (19)

References (20)
  • 2
    • 0032025109 scopus 로고    scopus 로고
    • Application of packed scrubber for air emissions control in municipal wastewater treatment plants
    • Basu, S., Gu, Z.C. and Shilinsky, K.A. (1998). Application of packed scrubber for air emissions control in municipal wastewater treatment plants. Environmental Progress, 17(1), 9-18.
    • (1998) Environmental Progress , vol.17 , Issue.1 , pp. 9-18
    • Basu, S.1    Gu, Z.C.2    Shilinsky, K.A.3
  • 4
    • 0003889680 scopus 로고
    • Les sources de nuisances olfactives dans les stations de traitement des eaux résiduaires et leur traitement par lavage à l'eau chlorée en solution basique
    • PhD thesis no. 725, University of Rennes, France
    • Bonnin, C. (1991). Les sources de nuisances olfactives dans les stations de traitement des eaux résiduaires et leur traitement par lavage à l'eau chlorée en solution basique. PhD thesis no. 725, University of Rennes, France.
    • (1991)
    • Bonnin, C.1
  • 5
    • 0035925268 scopus 로고    scopus 로고
    • A capacitance probe and a new model to identify and predict the capacity of columns equipped with structured packings
    • Brunazzi, E., Paglianti, A. and Pintus, S. (2001). A capacitance probe and a new model to identify and predict the capacity of columns equipped with structured packings. Industrial & Engineering Chemistry Research, 40, 1205-1212.
    • (2001) Industrial & Engineering Chemistry Research , vol.40 , pp. 1205-1212
    • Brunazzi, E.1    Paglianti, A.2    Pintus, S.3
  • 6
    • 0345729870 scopus 로고    scopus 로고
    • Fluid-dynamic and mass-transfer behavior of static mixers and regular packings
    • Cavatorta, O.N., Bohm, U. and Chiappori, A.M. (1999). Fluid-dynamic and mass-transfer behavior of static mixers and regular packings. AIChE Journal, 45(5), 938-948.
    • (1999) AIChE Journal , vol.45 , Issue.5 , pp. 938-948
    • Cavatorta, O.N.1    Bohm, U.2    Chiappori, A.M.3
  • 9
    • 0022557867 scopus 로고
    • Static mixers-criteria for applications and selection
    • Cybulski, A. and Werner, K. (1986). Static mixers-criteria for applications and selection. International Chemical Engineering, 26(1), 171-180.
    • (1986) International Chemical Engineering , vol.26 , Issue.1 , pp. 171-180
    • Cybulski, A.1    Werner, K.2
  • 10
    • 33845760429 scopus 로고    scopus 로고
    • Absorption of volatile organic compounds in a tower packed with a structured packing. II. Mass transfer
    • Dang, V.J., Manero, M.-H. and Roustan, M. (1998). Absorption of volatile organic compounds in a tower packed with a structured packing. II. Mass transfer. Entropie, 34(209), 11-17.
    • (1998) Entropie , vol.34 , Issue.209 , pp. 11-17
    • Dang, V.J.1    Manero, M.-H.2    Roustan, M.3
  • 12
    • 0035255275 scopus 로고    scopus 로고
    • Odour measurement for sewage treatment works
    • Gostelow, P., Parsons, S.A. and Stuez, R.M. (2001). Odour measurement for sewage treatment works. Water Research, 35(3), 579-597.
    • (2001) Water Research , vol.35 , Issue.3 , pp. 579-597
    • Gostelow, P.1    Parsons, S.A.2    Stuez, R.M.3
  • 14
    • 78049432524 scopus 로고    scopus 로고
    • Chemical and physical processes associated with mass transfer in odor control scrubbers
    • Cincinnati, United States
    • Hentz, L.H. and Balchunas, B.M. (2000). Chemical and physical processes associated with mass transfer in odor control scrubbers. Odors and VOC Emissions 2000, Conference Proceedings, Cincinnati, United States, pp. 16-19.
    • (2000) Odors and VOC Emissions 2000, Conference Proceedings , pp. 16-19
    • Hentz, L.H.1    Balchunas, B.M.2
  • 16
    • 0026448957 scopus 로고
    • The forecasting of hydrogen sulfide gas build-up in sewage collection systems
    • Matos, J.S. and Sousa, E.R. (1992). The forecasting of hydrogen sulfide gas build-up in sewage collection systems. Water Science Technology, 26(3-4), 915-922.
    • (1992) Water Science Technology , vol.26 , Issue.3-4 , pp. 915-922
    • Matos, J.S.1    Sousa, E.R.2
  • 17
    • 33845876577 scopus 로고    scopus 로고
    • Traitement par lavage oxydant d'atmosphères contaminées par des aldéhydes légers. Contribution au développement des mélangeurs statiques dans le traitement de la pollution gazeuse
    • PhD thesis no. 1650, University of Rennes, France
    • Péulier, M.-F. (1996). Traitement par lavage oxydant d'atmosphères contaminées par des aldéhydes légers. Contribution au développement des mélangeurs statiques dans le traitement de la pollution gazeuse. PhD thesis no. 1650, University of Rennes, France.
    • (1996)
    • Péulier, M.-F.1
  • 18
    • 22744438657 scopus 로고    scopus 로고
    • Transferts gaz-liquide dans les procédés de traitement des eaux et des effluents gazeux
    • In Paris
    • Roustan, M. (2003). Transferts gaz-liquide dans les procédés de traitement des eaux et des effluents gazeux. In Tech. & Doc, Lavoisier, Paris.
    • (2003) Tech. & Doc, Lavoisier
    • Roustan, M.1
  • 20
    • 0026878392 scopus 로고
    • Use of high intensity gas-liquid mixers as reactors
    • Zhu, Z.M., Hannon, J. and Green, A. (1992). Use of high intensity gas-liquid mixers as reactors. Chemical Engineering Science, 47(9-11), 2847-2852.
    • (1992) Chemical Engineering Science , vol.47 , Issue.9-11 , pp. 2847-2852
    • Zhu, Z.M.1    Hannon, J.2    Green, A.3