Effect of head surface roughness and sterilization method on wear of uhmwpe acetabular cups: Preliminary hip joint simulator results

Author keywords

Hip prostheses; Hip simulator; Roughened femoral heads; Surface roughness; UHMWPE; Wear

Indexed keywords

GAMMA RAYS; HIP PROSTHESES; JOINTS (STRUCTURAL COMPONENTS); LIGHT INTERFERENCE; LUBRICANTS; PROFILOMETRY; PROTEINS; SIMULATORS; WEAR OF MATERIALS;

EID: 33845808362     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1115/esda2006-95512     Document Type: Conference Paper
Times cited : (1)

References (24)
  • 2
    • 0030331924 scopus 로고    scopus 로고
    • Cellular basis for failure of joint prosthesis
    • Mohanty, M., 1996,"Cellular basis for failure of joint prosthesis", Bio Med Mater Eng 6, pp. 165-72.
    • (1996) Bio Med Mater Eng , vol.6 , pp. 165-172
    • Mohanty, M.1
  • 3
    • 0030632734 scopus 로고    scopus 로고
    • Biological reaction to debris in relation to joint prostheses
    • Proceedings of the Institution of Mechanical Engineers. Part H.
    • Revell, P. A., Al-Saffar, N., and Kobayashi, A., 1997,"Biological reaction to debris in relation to joint prostheses", Proceedings of the Institution of Mechanical Engineers. Part H. J Eng Med, 211, pp. 187-97.
    • (1997) J Eng Med , vol.211 , pp. 187-197
    • Revell, P.A.1    Al-Saffar, N.2    Kobayashi, A.3
  • 4
    • 0033868418 scopus 로고    scopus 로고
    • Femoral prosthetic heads and their significance in polyethylene wear
    • Falez, F., La Cava, F., and Panegrossi, G., 2000, "Femoral prosthetic heads and their significance in polyethylene wear", International Orthopeadics, 24, pp. 126-9.
    • (2000) International Orthopeadics , vol.24 , pp. 126-129
    • Falez, F.1    La Cava, F.2    Panegrossi, G.3
  • 5
    • 0031256146 scopus 로고    scopus 로고
    • The effect of surface topography of retrieved femoral heads on the wear of UHMWPE sockets
    • Hall, R. M., Siney, P., Unsworth, A., and Wroblewski, B. M., 1997,"The effect of surface topography of retrieved femoral heads on the wear of UHMWPE sockets", Med. Eng. Phys., 19(8), pp. 711-19.
    • (1997) Med. Eng. Phys. , vol.19 , Issue.8 , pp. 711-719
    • Hall, R.M.1    Siney, P.2    Unsworth, A.3    Wroblewski, B.M.4
  • 6
    • 10444263795 scopus 로고    scopus 로고
    • Identification of scratch mechanisms on a retrieved metallic femoral head
    • Najjar, D., Bigerelle, M., Migaud, H., and lost, A., 2005, "Identification of scratch mechanisms on a retrieved metallic femoral head", Wear, 258, pp. 240-50.
    • (2005) Wear , vol.258 , pp. 240-250
    • Najjar, D.1    Bigerelle, M.2    Migaud, H.3    Lost, A.4
  • 9
    • 0031686498 scopus 로고    scopus 로고
    • Effect of femoral head surface roughness on the wear of UHMWPE acetabular cups
    • Wang, A., Polineni, V. K., Stark, C., and Dumbleton, J. H., 1998,"Effect of femoral head surface roughness on the wear of UHMWPE acetabular cups", The Journal of Arthroplasty, 13(6), pp. 615-20.
    • (1998) The Journal of Arthroplasty , vol.13 , Issue.6 , pp. 615-620
    • Wang, A.1    Polineni, V.K.2    Stark, C.3    Dumbleton, J.H.4
  • 11
    • 10644277228 scopus 로고    scopus 로고
    • Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions
    • Affatato, S., Bersaglia, G., Rocchi, M., Taddei, P., Fagnano, C., and Toni, A., 2005,"Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions", Biomaterials, 26, pp. 3259-3267.
    • (2005) Biomaterials , vol.26 , pp. 3259-3267
    • Affatato, S.1    Bersaglia, G.2    Rocchi, M.3    Taddei, P.4    Fagnano, C.5    Toni, A.6
  • 13
    • 0028102058 scopus 로고
    • Post-irradiation aging of ultra-high molecular weight polyethylene
    • Rimnac, C. M., Klein, R. W., Betts, F., and Wright, T. M., 1994, "Post-irradiation aging of ultra-high molecular weight polyethylene", J Bone Joint Surg Am, 76, pp. 1052-6.
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 1052-1056
    • Rimnac, C.M.1    Klein, R.W.2    Betts, F.3    Wright, T.M.4
  • 14
    • 0020154315 scopus 로고
    • Analysis of retrieved implants: Cristallinity changes in ultra high molecular weight polyethylene
    • Grood, E. S., Sharstri, R., and Hopson, C. N., 1982,"Analysis of retrieved implants: cristallinity changes in ultra high molecular weight polyethylene", J Biomed Mater Res, 16, pp. 399-405.
    • (1982) J Biomed Mater Res , vol.16 , pp. 399-405
    • Grood, E.S.1    Sharstri, R.2    Hopson, C.N.3
  • 15
    • 0032775639 scopus 로고    scopus 로고
    • Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty
    • Kurtz, S. M., Muratoglu, O. K., Evans, M., and Edidin, A. A., 1999,"Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty ", Biomaterials, 20, pp. 1659-1688.
    • (1999) Biomaterials , vol.20 , pp. 1659-1688
    • Kurtz, S.M.1    Muratoglu, O.K.2    Evans, M.3    Edidin, A.A.4
  • 18
    • 0027407506 scopus 로고
    • In vivo wear of polyethylene acetabular components
    • Kabo, J. M., Gebhard, J. S., Loren, G., and Amstutz, H. C., 1993,"In vivo wear of polyethylene acetabular components", J Bone Joint Surg Br, 75-B(2), pp. 254-258.
    • (1993) J Bone Joint Surg Br , vol.75 B , Issue.2 , pp. 254-258
    • Kabo, J.M.1    Gebhard, J.S.2    Loren, G.3    Amstutz, H.C.4
  • 19
    • 0035053741 scopus 로고    scopus 로고
    • Influence of polyethylene and femoral head surface quality on wear: A retrieval study
    • Haraguchi, K., Sugano, N., and Nishii, T., 2001,"Influence of polyethylene and femoral head surface quality on wear: a retrieval study", International Orthopeadics, 25(1), pp. 29-34.
    • (2001) International Orthopeadics , vol.25 , Issue.1 , pp. 29-34
    • Haraguchi, K.1    Sugano, N.2    Nishii, T.3
  • 20
    • 0036435261 scopus 로고    scopus 로고
    • Wear of conventional and cross-linked UHMWPE acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator
    • Saikko, V., Calonius, O., and Keränen, J., 2002,"Wear of conventional and cross-linked UHMWPE acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator", Biomed Mater Res (Appl Biomater), 63, pp. 848-853.
    • (2002) Biomed Mater Res (Appl Biomater) , vol.63 , pp. 848-853
    • Saikko, V.1    Calonius, O.2    Keränen, J.3
  • 21
    • 0029725291 scopus 로고    scopus 로고
    • Effect of counterface material on the characteristics of retrieved uncemented cobalt-chromium and titanium alloy total hip replacements
    • Brummit, K., Hardaker, C. S., and McCullagh, P. J., 1996,"Effect of counterface material on the characteristics of retrieved uncemented cobalt-chromium and titanium alloy total hip replacements", Proc Inst Mech Eng [H], 210, pp. 191-5.
    • (1996) Proc Inst Mech Eng [H] , vol.210 , pp. 191-195
    • Brummit, K.1    Hardaker, C.S.2    McCullagh, P.J.3
  • 22
    • 0034485401 scopus 로고    scopus 로고
    • A hip joint simulator study using new and physiologically scratched femoral heads with UHMWPE acetabular cups
    • Barbour, P. S. M., Stone, M. H., and Fisher, J., 2000,"A hip joint simulator study using new and physiologically scratched femoral heads with UHMWPE acetabular cups", Proc Instn Mech Engrs: Part H, 214, pp. 569-76.
    • (2000) Proc Instn Mech Engrs: Part H , vol.214 , pp. 569-576
    • Barbour, P.S.M.1    Stone, M.H.2    Fisher, J.3
  • 23
    • 0035481958 scopus 로고    scopus 로고
    • A hip simulator study of the influence of patient activity level on the wear of crosslinked polyethylene under smooth and roughened femoral conditions
    • Bowsher, J. G., 2001,"A hip simulator study of the influence of patient activity level on the wear of crosslinked polyethylene under smooth and roughened femoral conditions ", Wear, 250, pp. 167-79.
    • (2001) Wear , vol.250 , pp. 167-179
    • Bowsher, J.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.