메뉴 건너뛰기




Volumn 22, Issue 1, 2007, Pages 136-139

Delayed Fracture of a Ceramic Insert With Modern Ceramic Total Hip Replacement

Author keywords

ceramic liner fracture; impingement; total hip arthroplasty

Indexed keywords

ADULT; ARTHROTOMY; ARTICLE; BONE NECROSIS; CASE REPORT; CERAMIC LINER FRACTURE; CERAMIC PROSTHESIS; CERAMICS; FEMUR HEAD; HIP; HISTOLOGY; HUMAN; HUMAN TISSUE; MALE; POSTOPERATIVE PERIOD; PROSTHESIS FAILURE; SITTING; SURGICAL APPROACH; TOTAL HIP PROSTHESIS; X RAY FILM;

EID: 33845789738     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2005.12.012     Document Type: Article
Times cited : (36)

References (15)
  • 1
    • 0026782886 scopus 로고
    • Role of ceramic implants. Design and clinical success with total hip prosthetic ceramic-to-ceramic bearings
    • Clarke I.C. Role of ceramic implants. Design and clinical success with total hip prosthetic ceramic-to-ceramic bearings. Clin Orthop Relat Res 282 (1992) 19
    • (1992) Clin Orthop Relat Res , vol.282 , pp. 19
    • Clarke, I.C.1
  • 2
    • 0036083725 scopus 로고    scopus 로고
    • New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty
    • D'Antonio J., Capello W., Manley M., et al. New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty. J Arthroplasty 17 (2002) 390
    • (2002) J Arthroplasty , vol.17 , pp. 390
    • D'Antonio, J.1    Capello, W.2    Manley, M.3
  • 3
    • 0041419860 scopus 로고    scopus 로고
    • Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup
    • Hasegawa M., Sudo A., Hirata H., et al. Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup. J Arthroplasty 18 (2003) 658
    • (2003) J Arthroplasty , vol.18 , pp. 658
    • Hasegawa, M.1    Sudo, A.2    Hirata, H.3
  • 4
    • 0037326896 scopus 로고    scopus 로고
    • Fracture of a ceramic acetabular insert after ceramic-on-ceramic THA-a case report
    • Suzuki K., Matsubara M., Morita S., et al. Fracture of a ceramic acetabular insert after ceramic-on-ceramic THA-a case report. Acta Orthop Scand 74 (2003) 101
    • (2003) Acta Orthop Scand , vol.74 , pp. 101
    • Suzuki, K.1    Matsubara, M.2    Morita, S.3
  • 5
    • 0141924420 scopus 로고    scopus 로고
    • Mechanical performance of ceramic acetabular liners under impact conditions
    • Maher S.A., Lipman J.D., Curley L.J., et al. Mechanical performance of ceramic acetabular liners under impact conditions. J Arthroplasty 18 (2003) 936
    • (2003) J Arthroplasty , vol.18 , pp. 936
    • Maher, S.A.1    Lipman, J.D.2    Curley, L.J.3
  • 6
    • 0033771090 scopus 로고    scopus 로고
    • Press-fit metal-backed alumina sockets. A minimum 5-year followup study
    • Bizot P., Larrouy M., Witvoet J., et al. Press-fit metal-backed alumina sockets. A minimum 5-year followup study. Clin Orthop Relat Res 379 (2000) 134
    • (2000) Clin Orthop Relat Res , vol.379 , pp. 134
    • Bizot, P.1    Larrouy, M.2    Witvoet, J.3
  • 7
    • 0029902177 scopus 로고    scopus 로고
    • Ceramic femoral head fracture in total hip arthroplasty
    • Fritsch E.W., and Gleitz M. Ceramic femoral head fracture in total hip arthroplasty. Clin Orthop Relat Res 328 (1996) 129
    • (1996) Clin Orthop Relat Res , vol.328 , pp. 129
    • Fritsch, E.W.1    Gleitz, M.2
  • 8
    • 0029558604 scopus 로고
    • Spontaneous fracture of the ceramic ball in a ceramic-polyethylene total hip arthroplasty
    • Michaud R.J., and Rashad S.Y. Spontaneous fracture of the ceramic ball in a ceramic-polyethylene total hip arthroplasty. J Arthroplasty 6 (1995) 863
    • (1995) J Arthroplasty , vol.6 , pp. 863
    • Michaud, R.J.1    Rashad, S.Y.2
  • 9
    • 0001549373 scopus 로고    scopus 로고
    • Ceramics in total hip arthroplasty: history, mechanical properties, clinical results, and current manufacturing state of the art
    • Heros R.J., and Willmann G. Ceramics in total hip arthroplasty: history, mechanical properties, clinical results, and current manufacturing state of the art. Semin Arthroplasty 9 (1998) 114
    • (1998) Semin Arthroplasty , vol.9 , pp. 114
    • Heros, R.J.1    Willmann, G.2
  • 10
    • 2642584746 scopus 로고    scopus 로고
    • Edge loading in third generation alumina ceramic-on-ceramic bearings: stripe wear
    • Walter W.L., Insley G.M., Walter W.K., et al. Edge loading in third generation alumina ceramic-on-ceramic bearings: stripe wear. J Arthroplasty 19 (2004) 402
    • (2004) J Arthroplasty , vol.19 , pp. 402
    • Walter, W.L.1    Insley, G.M.2    Walter, W.K.3
  • 11
    • 0345491958 scopus 로고    scopus 로고
    • Fractures of ceramic bearings: history and present status
    • Hannouche D., Nich C., Bizot P., et al. Fractures of ceramic bearings: history and present status. Clin Orthop Relat Res 417 (2003) 19
    • (2003) Clin Orthop Relat Res , vol.417 , pp. 19
    • Hannouche, D.1    Nich, C.2    Bizot, P.3
  • 12
    • 0033779502 scopus 로고    scopus 로고
    • Modern ceramic-on-ceramic total hip systems in the United States: early results
    • Garino J.P. Modern ceramic-on-ceramic total hip systems in the United States: early results. Clin Orthop Relat Res 379 (2000) 41
    • (2000) Clin Orthop Relat Res , vol.379 , pp. 41
    • Garino, J.P.1
  • 13
    • 0034868709 scopus 로고    scopus 로고
    • Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants
    • Mulholland S.J., and Wyss U.P. Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants. Int J Rehabil Res 24 (2001) 191
    • (2001) Int J Rehabil Res , vol.24 , pp. 191
    • Mulholland, S.J.1    Wyss, U.P.2
  • 14
    • 0034114175 scopus 로고    scopus 로고
    • The spatial location of impingement in total hip arthroplasty
    • Yamaguchi M., Akisue T., Bauer T.W., et al. The spatial location of impingement in total hip arthroplasty. J Arthroplasty 15 (2000) 305
    • (2000) J Arthroplasty , vol.15 , pp. 305
    • Yamaguchi, M.1    Akisue, T.2    Bauer, T.W.3
  • 15
    • 0024992964 scopus 로고
    • Massive wear of a steel ball head by ceramic fragments in the polyethylene acetabular cup after revision of a total hip prosthesis with fractured ceramic ball
    • Kempf I., and Semlitsch M. Massive wear of a steel ball head by ceramic fragments in the polyethylene acetabular cup after revision of a total hip prosthesis with fractured ceramic ball. Arch Orthop Trauma Surg 109 (1990) 284
    • (1990) Arch Orthop Trauma Surg , vol.109 , pp. 284
    • Kempf, I.1    Semlitsch, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.