메뉴 건너뛰기




Volumn 88, Issue 12, 2006, Pages 1652-1653

Fracture of the stem of the femoral component after resurfacing arthroplasty of the hip

Author keywords

[No Author keywords available]

Indexed keywords

BONE CEMENT;

EID: 33845757713     PISSN: 0301620X     EISSN: None     Source Type: Journal    
DOI: 10.1302/0301-620X.88B12.18299     Document Type: Article
Times cited : (16)

References (7)
  • 1
    • 17044401726 scopus 로고    scopus 로고
    • Complications associated with hip resurfacing arthroplasty
    • Shimmin AJ, Bare J, Back DL. Complications associated with hip resurfacing arthroplasty. Orthop Clin North Am 2005;36:187-93.
    • (2005) Orthop Clin North Am , vol.36 , pp. 187-193
    • Shimmin, A.J.1    Bare, J.2    Back, D.L.3
  • 2
    • 15044348747 scopus 로고    scopus 로고
    • Early results of primary Birmingham hip resufacings: At independent prospective study of the first 230 hips
    • Back DL, Dalziel R, Young D, Shimmin A. Early results of primary Birmingham hip resufacings: at independent prospective study of the first 230 hips. J Bone Joint Surg [Br] 2005;87-B:324-9.
    • (2005) J Bone Joint Surg [Br] , vol.87 B , pp. 324-329
    • Back, D.L.1    Dalziel, R.2    Young, D.3    Shimmin, A.4
  • 3
    • 16244401409 scopus 로고    scopus 로고
    • The nonoperative management of periprosthetic fractures associated with the Birmingham hip resurfacing procedure
    • Cossey AJ, Back DL, Shimmin A, Young D, Spriggins AJ, The nonoperative management of periprosthetic fractures associated with the Birmingham hip resurfacing procedure. J Arthroplasty 2005;20:358-61.
    • (2005) J Arthroplasty , vol.20 , pp. 358-361
    • Cossey, A.J.1    Back, D.L.2    Shimmin, A.3    Young, D.4    Spriggins, A.J.5
  • 4
    • 0029810740 scopus 로고    scopus 로고
    • Metal on metal surface replacement of the hip: Experience of the McMinn prosthesis
    • McMinn D, Treacy R, Lin K, Pynsent P. Metal on metal surface replacement of the hip: experience of the McMinn prosthesis. Clin Orthop 1996;329(Suppl):89-98.
    • (1996) Clin Orthop , vol.329 , Issue.SUPPL. , pp. 89-98
    • McMinn, D.1    Treacy, R.2    Lin, K.3    Pynsent, P.4
  • 5
    • 1642404356 scopus 로고    scopus 로고
    • Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis
    • Daniel J, Pynsent PB, McMinn DJW. Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis. J Bone Joint Surg [Br] 2004;86-B:177-84.
    • (2004) J Bone Joint Surg [Br] , vol.86 B , pp. 177-184
    • Daniel, J.1    Pynsent, P.B.2    McMinn, D.J.W.3
  • 7
    • 33845757524 scopus 로고    scopus 로고
    • Static and fatigue testing of 56 mm Cormet resurfacing heads (FDA)
    • Engineer's Report
    • Lewis O. Static and fatigue testing of 56 mm Cormet resurfacing heads (FDA). Engineer's Report 2005.
    • (2005)
    • Lewis, O.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.