메뉴 건너뛰기




Volumn 40, Issue 1, 2007, Pages 11-17

Dynamic recording of irrigating fluid distribution in root canals using thermal image analysis

Author keywords

File diameter; Irrigation; Root canal surgery; Thermal image analysis; Tooth

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS;

EID: 33845739323     PISSN: 01432885     EISSN: 13652591     Source Type: Journal    
DOI: 10.1111/j.1365-2591.2006.01168.x     Document Type: Article
Times cited : (71)

References (25)
  • 1
    • 0020187691 scopus 로고
    • The effectiveness of four clinical irrigation methods on the removal of root canal debris
    • Abou-Rass M, Piccinino MV (1982) The effectiveness of four clinical irrigation methods on the removal of root canal debris. Oral Surgery, Oral Medicine, Oral Pathology 54, 323-8.
    • (1982) Oral Surgery, Oral Medicine, Oral Pathology , vol.54 , pp. 323-328
    • Abou-Rass, M.1    Piccinino, M.V.2
  • 3
    • 0029448307 scopus 로고
    • An in vitro study of apical extrusion of sodium hypochlorite during endodontic canal preparation
    • Brown DC, Moore BK, Brown CE Jr, Newton CW (1995) An in vitro study of apical extrusion of sodium hypochlorite during endodontic canal preparation. Journal of Endodontics 21, 587-91.
    • (1995) Journal of Endodontics , vol.21 , pp. 587-591
    • Brown, D.C.1    Moore, B.K.2    Brown Jr., C.E.3    Newton, C.W.4
  • 5
    • 22244455731 scopus 로고    scopus 로고
    • Infrared thermography to mass-screen suspected SARS patients with fever
    • Chiu WT, Lin PW, Chiou HY et al. (2005) Infrared thermography to mass-screen suspected SARS patients with fever. Asia Pacific Journal of Public Health 17, 26-8.
    • (2005) Asia Pacific Journal of Public Health , vol.17 , pp. 26-28
    • Chiu, W.T.1    Lin, P.W.2    Chiou, H.Y.3
  • 6
    • 0020852519 scopus 로고
    • Mechanical effectiveness of root canal irrigation
    • Chow TW (1983) Mechanical effectiveness of root canal irrigation. Journal of Endodontics 9, 475-9.
    • (1983) Journal of Endodontics , vol.9 , pp. 475-479
    • Chow, T.W.1
  • 7
    • 33845802268 scopus 로고
    • Applications of the derivative
    • Coughlin R, ed. Boston, MA: Allyn and Bacon
    • Coughlin R (1976) Applications of the derivative. In: Coughlin R, ed. Applied Calculus, 1st edn. Boston, MA: Allyn and Bacon, pp. 110-1.
    • (1976) Applied Calculus, 1st Edn. , pp. 110-111
    • Coughlin, R.1
  • 8
    • 0036894844 scopus 로고    scopus 로고
    • Vision of the future: Initial experience with intraoperative real-time high-resolution dynamic infrared imaging. Technical note
    • Ecker RD, Goerss SJ, Meyer FB, Cohen-Gadol AA, Britton JW, Levine JA (2002) Vision of the future: initial experience with intraoperative real-time high-resolution dynamic infrared imaging. Technical note. Journal of Neurosurgery 97, 1460-71.
    • (2002) Journal of Neurosurgery , vol.97 , pp. 1460-1471
    • Ecker, R.D.1    Goerss, S.J.2    Meyer, F.B.3    Cohen-Gadol, A.A.4    Britton, J.W.5    Levine, J.A.6
  • 9
    • 26844477889 scopus 로고    scopus 로고
    • The influence of preparation size on the mechanical efficacy of root canal irrigation in vitro
    • Falk KW, Sedgley CM (2005) The influence of preparation size on the mechanical efficacy of root canal irrigation in vitro. Journal of Endodontics 31, 742-5.
    • (2005) Journal of Endodontics , vol.31 , pp. 742-745
    • Falk, K.W.1    Sedgley, C.M.2
  • 10
    • 8444244818 scopus 로고    scopus 로고
    • Infrared thermography for examination of skin temperature in the dorsal hand of office workers
    • Gold JE, Cherniack M, Buchholz B (2004) Infrared thermography for examination of skin temperature in the dorsal hand of office workers. European Journal of Applied Physiology 93, 245-51.
    • (2004) European Journal of Applied Physiology , vol.93 , pp. 245-251
    • Gold, J.E.1    Cherniack, M.2    Buchholz, B.3
  • 11
    • 0042730173 scopus 로고    scopus 로고
    • Effectiveness of 2% chlorhexidine gel and calcium hydroxide against Enterococcus faecalis in bovine root dentine in vitro
    • Gomes BP, Souza SF, Ferraz CC et al. (2003) Effectiveness of 2% chlorhexidine gel and calcium hydroxide against Enterococcus faecalis in bovine root dentine in vitro. International Endodontic Journal 36, 267-75.
    • (2003) International Endodontic Journal , vol.36 , pp. 267-275
    • Gomes, B.P.1    Souza, S.F.2    Ferraz, C.C.3
  • 12
    • 0043261613 scopus 로고    scopus 로고
    • A comparative study of root canal preparation using FlexMaster and HERO 642 rotary Ni-Ti instruments
    • Hülsmann M, Gressmann G, Schafers F (2003a) A comparative study of root canal preparation using FlexMaster and HERO 642 rotary Ni-Ti instruments. International Endodontic Journal 36, 358-66.
    • (2003) International Endodontic Journal , vol.36 , pp. 358-366
    • Hülsmann, M.1    Gressmann, G.2    Schafers, F.3
  • 13
    • 17144448593 scopus 로고    scopus 로고
    • Comparative study of root-canal preparation using Lightspeed and Quantec SC rotary NiTi instruments
    • Hülsmann M, Herbst U, Schafers F (2003b) Comparative study of root-canal preparation using Lightspeed and Quantec SC rotary NiTi instruments. International Endodontic Journal 36, 748-56.
    • (2003) International Endodontic Journal , vol.36 , pp. 748-756
    • Hülsmann, M.1    Herbst, U.2    Schafers, F.3
  • 14
    • 0029302684 scopus 로고
    • An in vitro evaluation of the irrigating characteristics of ultrasonic and subsonic handpieces and irrigating needles and probes
    • Kahn FH, Rosenberg PA, Gliksberg J (1995) An in vitro evaluation of the irrigating characteristics of ultrasonic and subsonic handpieces and irrigating needles and probes. Journal of Endodontics 21, 277-80.
    • (1995) Journal of Endodontics , vol.21 , pp. 277-280
    • Kahn, F.H.1    Rosenberg, P.A.2    Gliksberg, J.3
  • 15
    • 1642525856 scopus 로고    scopus 로고
    • Application of thermography in dentistry-visualization of temperature distribution on oral tissues
    • Komoriyama M, Nomoto R, Tanaka R et al. (2003) Application of thermography in dentistry-visualization of temperature distribution on oral tissues. Dental Materials Journal 22, 436-43.
    • (2003) Dental Materials Journal , vol.22 , pp. 436-443
    • Komoriyama, M.1    Nomoto, R.2    Tanaka, R.3
  • 16
    • 0034232121 scopus 로고    scopus 로고
    • A comparison of thermocouple and infrared thermographic analysis of temperature rise on the root surface during the continuous wave of condensation technique
    • Mc Cullagh JJ, Setchell DJ, Gulabivala K et al. (2000) A comparison of thermocouple and infrared thermographic analysis of temperature rise on the root surface during the continuous wave of condensation technique. International Endodontic Journal 33, 326-32.
    • (2000) International Endodontic Journal , vol.33 , pp. 326-332
    • Mc Cullagh, J.J.1    Setchell, D.J.2    Gulabivala, K.3
  • 21
    • 13544266362 scopus 로고    scopus 로고
    • Influence of irrigant needle depth in removing bioluminescent bacteria inoculated into instrumented root canals using real-time imaging in vitro
    • Sedgley CM, Nagel AC, Hall D, Applegate B (2005) Influence of irrigant needle depth in removing bioluminescent bacteria inoculated into instrumented root canals using real-time imaging in vitro. International Endodontic Journal 38, 97-104.
    • (2005) International Endodontic Journal , vol.38 , pp. 97-104
    • Sedgley, C.M.1    Nagel, A.C.2    Hall, D.3    Applegate, B.4
  • 22
    • 3442900294 scopus 로고    scopus 로고
    • Infrared thermographic SAR measurements of interstitial hyperthermia applicators: Errors due to thermal conduction and convection
    • Sherar MD, Gladman AS, Davidson SR, Easty AC, Joy ML (2004) Infrared thermographic SAR measurements of interstitial hyperthermia applicators: errors due to thermal conduction and convection. International Journal of Hyperthermia 20, 539-55.
    • (2004) International Journal of Hyperthermia , vol.20 , pp. 539-555
    • Sherar, M.D.1    Gladman, A.S.2    Davidson, S.R.3    Easty, A.C.4    Joy, M.L.5
  • 23
    • 24344499077 scopus 로고    scopus 로고
    • Skin temperature increase caused by a mobile phone: A methodological infrared camera study
    • Straume A, Oftedal G, Johnsson A (2005) Skin temperature increase caused by a mobile phone: a methodological infrared camera study. Bioelectromagnetics 26, 510-9.
    • (2005) Bioelectromagnetics , vol.26 , pp. 510-519
    • Straume, A.1    Oftedal, G.2    Johnsson, A.3
  • 24
    • 19044400059 scopus 로고    scopus 로고
    • The effect of application time of EDTA and NaOCl on intracanal smear layer removal: An SEM analysis
    • Teixeira CS, Felippe MC, Felippe WT (2005) The effect of application time of EDTA and NaOCl on intracanal smear layer removal: an SEM analysis. International Endodontic Journal 38, 285-90.
    • (2005) International Endodontic Journal , vol.38 , pp. 285-290
    • Teixeira, C.S.1    Felippe, M.C.2    Felippe, W.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.