메뉴 건너뛰기




Volumn 71, Issue 1, 2007, Pages 74-78

Plasma creatinine determination in mice and rats: An enzymatic method compares favorably with a high-performance liquid chromatography assay

Author keywords

Colorimetric; Determination methods; Enzymatic; HPLC; Jaff ; Plasma creatinine

Indexed keywords

HEMOGLOBIN; PICRIC ACID;

EID: 33845698003     PISSN: 00852538     EISSN: 15231755     Source Type: Journal    
DOI: 10.1038/sj.ki.5001988     Document Type: Article
Times cited : (114)

References (14)
  • 1
    • 0000841697 scopus 로고
    • Über den Niederschag, welchen Pikrinsäure in normalem Harn erzeugt und über eine neue Reaktion des Kreatinins
    • Jaffé M. Über den Niederschag, welchen Pikrinsäure in normalem Harn erzeugt und über eine neue Reaktion des Kreatinins. Z Physiol Chem 1886; 10: 391-400.
    • (1886) Z Physiol Chem , vol.10 , pp. 391-400
    • Jaffé, M.1
  • 2
    • 0026350189 scopus 로고
    • Effects of interferents on the kinetic Jaffe reaction and an enzymatic colorimetric test for serum creatinine concentration determination in cats, cows, dogs and horses
    • Jacobs RM, Lumsden JH, Taylor JA, Grift E. Effects of interferents on the kinetic Jaffe reaction and an enzymatic colorimetric test for serum creatinine concentration determination in cats, cows, dogs and horses. Can J Vet Res 1991; 55: 150-154.
    • (1991) Can J Vet Res , vol.55 , pp. 150-154
    • Jacobs, R.M.1    Lumsden, J.H.2    Taylor, J.A.3    Grift, E.4
  • 3
    • 84945736974 scopus 로고
    • Multicentre evaluation of an enzymatic method for creatinine determination using a sensitive colour reagent
    • Guder WG, Hoffman GE, Hubbuch A et al. Multicentre evaluation of an enzymatic method for creatinine determination using a sensitive colour reagent. J Clin Chem Clin Biochem 1986; 24: 889-902.
    • (1986) J Clin Chem Clin Biochem , vol.24 , pp. 889-902
    • Guder, W.G.1    Hoffman, G.E.2    Hubbuch, A.3
  • 4
    • 0021950177 scopus 로고
    • Picric acid methods greatly overestimate serum creatinine in mice: More accurate results with high-performance liquid chromatography
    • Meyer MH, Meyer Jr RA, Gray RW, Irwin RL. Picric acid methods greatly overestimate serum creatinine in mice: more accurate results with high-performance liquid chromatography. Anal Biochem 1985; 144: 285-290.
    • (1985) Anal Biochem , vol.144 , pp. 285-290
    • Meyer, M.H.1    Meyer Jr., R.A.2    Gray, R.W.3    Irwin, R.L.4
  • 5
    • 15044365735 scopus 로고    scopus 로고
    • Protective effects of exogenous bilirubin on ischemia-reperfusion injury in the isolated, perfused rat kidney
    • Adin CA, Croker BP, Agarwal A. Protective effects of exogenous bilirubin on ischemia-reperfusion injury in the isolated, perfused rat kidney. Am J Physiol Renal Physiol 2005; 288: F778-F784.
    • (2005) Am J Physiol Renal Physiol , vol.288
    • Adin, C.A.1    Croker, B.P.2    Agarwal, A.3
  • 6
    • 33646525690 scopus 로고    scopus 로고
    • S1P(1)-selective agonist, SEW2871, ameliorates ischemic acute renal failure
    • Lien YH, Yong KC, Cho C et al. S1P(1)-selective agonist, SEW2871, ameliorates ischemic acute renal failure. Kidney Int 2006; 69: 1601-1608.
    • (2006) Kidney Int , vol.69 , pp. 1601-1608
    • Lien, Y.H.1    Yong, K.C.2    Cho, C.3
  • 7
    • 2442717665 scopus 로고    scopus 로고
    • A simplified method for HPLC determination of creatinine in mouse serum
    • Yuen PS, Dunn SR, Miyaji T et al. A simplified method for HPLC determination of creatinine in mouse serum. Am J Physiol Renal Physiol 2004; 286: F1116-F1119.
    • (2004) Am J Physiol Renal Physiol , vol.286
    • Yuen, P.S.1    Dunn, S.R.2    Miyaji, T.3
  • 8
    • 2342570276 scopus 로고    scopus 로고
    • Utility of endogenous creatinine clearance as a measure of renal function in mice
    • Dunn SR, Qi Z, Bottinger EP et al. Utility of endogenous creatinine clearance as a measure of renal function in mice. Kidney Int 2004; 65: 1959-1967.
    • (2004) Kidney Int , vol.65 , pp. 1959-1967
    • Dunn, S.R.1    Qi, Z.2    Bottinger, E.P.3
  • 9
    • 0035882771 scopus 로고    scopus 로고
    • Simple high-performance liquid chromatographic method to analyze serum creatinine has several advantages over the Jaffe picric acid reaction as demonstrated with a cimetidine dose response in rhesus monkeys
    • Johns BA, Broten T, Stranieri MT et al. Simple high-performance liquid chromatographic method to analyze serum creatinine has several advantages over the Jaffe picric acid reaction as demonstrated with a cimetidine dose response in rhesus monkeys. J Chromatogr B Biomed Sci Appl 2001; 759: 343-348.
    • (2001) J Chromatogr B Biomed Sci Appl , vol.759 , pp. 343-348
    • Johns, B.A.1    Broten, T.2    Stranieri, M.T.3
  • 10
    • 1642574218 scopus 로고    scopus 로고
    • Simplified HPLC method for urinary and circulating creatinine
    • Tsikas D, Wolf A, Frolich JC. Simplified HPLC method for urinary and circulating creatinine. Clin Chem 2004; 50: 201-203.
    • (2004) Clin Chem , vol.50 , pp. 201-203
    • Tsikas, D.1    Wolf, A.2    Frolich, J.C.3
  • 11
    • 0030882598 scopus 로고    scopus 로고
    • Interferences of o-raffinose cross-linked hemoglobin in three methods for serum creatinine
    • Ali AC, Mihas CC, Campbell JA. Interferences of o-raffinose cross-linked hemoglobin in three methods for serum creatinine. Clin Chem 1997; 43: 1738-1743.
    • (1997) Clin Chem , vol.43 , pp. 1738-1743
    • Ali, A.C.1    Mihas, C.C.2    Campbell, J.A.3
  • 12
    • 0016176428 scopus 로고
    • Free haemoglobin and the mechanical and osmotic resistence of red blood cells in laboratory animals
    • Viktora L, Jozova O, Zoubkova M. Free haemoglobin and the mechanical and osmotic resistence of red blood cells in laboratory animals. Physiol Bohemoslov 1974; 23: 565-568.
    • (1974) Physiol Bohemoslov , vol.23 , pp. 565-568
    • Viktora, L.1    Jozova, O.2    Zoubkova, M.3
  • 13
    • 33749268006 scopus 로고    scopus 로고
    • A truncated polycystin-2 protein causes polycystic kidney disease and retinal degeneration in transgenic rats
    • Gallagher AR, Hoffman S, Brown N et al. A truncated polycystin-2 protein causes polycystic kidney disease and retinal degeneration in transgenic rats. J Am Soc Nephrol 2006; 17: 2719-2730.
    • (2006) J Am Soc Nephrol , vol.17 , pp. 2719-2730
    • Gallagher, A.R.1    Hoffman, S.2    Brown, N.3
  • 14
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 327: 307-310.
    • (1986) Lancet , vol.327 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.