메뉴 건너뛰기




Volumn 2006, Issue , 2006, Pages 2972-2977

Contact probe based stiffness sensing of human eye

Author keywords

Eye stiffness; Medical application; Static sensing

Indexed keywords

CAMERAS; MEDICAL APPLICATIONS; OPTICAL RESOLVING POWER; PRESSURE MEASUREMENT; ROBOTICS; STIFFNESS;

EID: 33845682604     PISSN: 10504729     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ROBOT.2006.1642153     Document Type: Conference Paper
Times cited : (1)

References (20)
  • 4
    • 0034809620 scopus 로고    scopus 로고
    • Nondestructive measurement of kiwifruit ripeness using a laser doppler vibrometer
    • S. Terasaki, N. Wada, N. Sakurai, N. Muramatsu, and D. J. Nevins. Nondestructive measurement of kiwifruit ripeness using a laser doppler vibrometer. Trans. of ASME, 44(1):81-88, 2001.
    • (2001) Trans. of ASME , vol.44 , Issue.1 , pp. 81-88
    • Terasaki, S.1    Wada, N.2    Sakurai, N.3    Muramatsu, N.4    Nevins, D.J.5
  • 6
    • 0002523438 scopus 로고
    • Applanation tonometry
    • F. W. Newell, editor, New York: Josiah Macy, Jr, Foundation
    • H. Goldmann. Applanation tonometry. In F. W. Newell, editor, Glaucoma; Transactions of the Second Conference, pages 167-220. New York: Josiah Macy, Jr, Foundation, 1957.
    • (1957) Glaucoma; Transactions of the Second Conference , pp. 167-220
    • Goldmann, H.1
  • 7
    • 33845672706 scopus 로고    scopus 로고
    • Topcon corporation, http://www.topcon.co.jp/.
  • 8
    • 21344456718 scopus 로고    scopus 로고
    • A comparison of four methods of tonometry: Method agreement and interobserver variablity
    • P-A. Tonnu, T. Ho, K. Sharma, E. White, C. Bunce, and D. Garway-Heath. A comparison of four methods of tonometry: method agreement and interobserver variablity. Br. J. Ophthalmol., 89:847-850, 2005.
    • (2005) Br. J. Ophthalmol. , vol.89 , pp. 847-850
    • Tonnu, P.-A.1    Ho, T.2    Sharma, K.3    White, E.4    Bunce, C.5    Garway-Heath, D.6
  • 9
    • 0016261804 scopus 로고
    • Central corneal thickness in low tension glaucoma
    • N. Ehlers and F. K. Hansen. Central corneal thickness in low tension glaucoma. Acta Ophthalmol., 54:740-746, 1974.
    • (1974) Acta Ophthalmol. , vol.54 , pp. 740-746
    • Ehlers, N.1    Hansen, F.K.2
  • 10
    • 0018902756 scopus 로고
    • Low tension glaucoma: A critical review and new material
    • R. Z. Levene. Low tension glaucoma: a critical review and new material. Surv. Ophthalmol., 24:621-631, 1980.
    • (1980) Surv. Ophthalmol. , vol.24 , pp. 621-631
    • Levene, R.Z.1
  • 11
    • 0032006955 scopus 로고    scopus 로고
    • Corneal thickness and curvature in normal-tension glaucoma
    • Y. Morad, E. Sharon, L. Hefetz, and P. Nemet. Corneal thickness and curvature in normal-tension glaucoma. Am. J. Ophthalmol., 125:164-168, 1998.
    • (1998) Am. J. Ophthalmol. , vol.125 , pp. 164-168
    • Morad, Y.1    Sharon, E.2    Hefetz, L.3    Nemet, P.4
  • 12
    • 33845604082 scopus 로고
    • Corneal topography and elasticity in normal and keratoconic eyes
    • C. Edmund. Corneal topography and elasticity in normal and keratoconic eyes. Acta Ophthalmol., 44:367-408, 1989.
    • (1989) Acta Ophthalmol. , vol.44 , pp. 367-408
    • Edmund, C.1
  • 13
    • 0030199985 scopus 로고    scopus 로고
    • Regional elastic performance of the human cornea
    • J. O. Hjortdal. Regional elastic performance of the human cornea. J. Biomechanics, 29(7):931-942, 1996.
    • (1996) J. Biomechanics , vol.29 , Issue.7 , pp. 931-942
    • Hjortdal, J.O.1
  • 14
    • 0141682012 scopus 로고    scopus 로고
    • Intraocular pressure, goldmann applanation tension, corneal thickness and curvature in caucasians, asians, hispanics, and african americans
    • M. Shimmyo, A. J. Ross, A. Moy, and R. Mostafavi. Intraocular pressure, goldmann applanation tension, corneal thickness and curvature in caucasians, asians, hispanics, and african americans. Am. J. Ophthalmol., 136:603-613, 2003.
    • (2003) Am. J. Ophthalmol. , vol.136 , pp. 603-613
    • Shimmyo, M.1    Ross, A.J.2    Moy, A.3    Mostafavi, R.4
  • 15
    • 0033021344 scopus 로고    scopus 로고
    • Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo
    • G. J. Orssengo and D. C. Pye. Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo. Bull. Math. Biol., 61:551-572, 1999.
    • (1999) Bull. Math. Biol. , vol.61 , pp. 551-572
    • Orssengo, G.J.1    Pye, D.C.2
  • 16
    • 0025785926 scopus 로고
    • A microstructurally-based finite element model of the incised human cornea
    • P. M. Pinsky and D. V. Datye. A microstructurally-based finite element model of the incised human cornea. J. Biomechanics, 24:907-922, 1991.
    • (1991) J. Biomechanics , vol.24 , pp. 907-922
    • Pinsky, P.M.1    Datye, D.V.2
  • 17
    • 0030297968 scopus 로고    scopus 로고
    • Constitutive laws for biomechanical modeling of refractive surgery
    • M. R. Bryant and P. J. McDonnell. Constitutive laws for biomechanical modeling of refractive surgery. J. Biomech. Eng., 118:473-481, 1996.
    • (1996) J. Biomech. Eng. , vol.118 , pp. 473-481
    • Bryant, M.R.1    McDonnell, P.J.2
  • 20
    • 1542346230 scopus 로고    scopus 로고
    • Stiffness and contact mechanics for soft fingers in grasping and manipulation
    • I. Kao and F. Yang. Stiffness and contact mechanics for soft fingers in grasping and manipulation. IEEE Trans.on Robotics and Automation, 20(1):132-135, 2004
    • (2004) IEEE Trans.on Robotics and Automation , vol.20 , Issue.1 , pp. 132-135
    • Kao, I.1    Yang, F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.