메뉴 건너뛰기




Volumn 14, Issue 1, 2007, Pages 2-8

Psychometric properties of measurement tools for quantifying knee joint position and movement: A systematic review

Author keywords

Knee; Measurement; Reliability; Review; Systematic review

Indexed keywords

ANALYTICAL ERROR; BIOMEDICAL ENGINEERING; CONCURRENT VALIDITY; DATA BASE; GONIOMETRY; GRAVITY; HUMAN; KNEE; MEASUREMENT; MOTION ANALYSIS SYSTEM; NUCLEAR MAGNETIC RESONANCE IMAGING; PHOTOGRAPHY; PRIORITY JOURNAL; PSYCHOMETRY; QUANTITATIVE ANALYSIS; RELIABILITY; REVIEW; STANDARD; SYSTEMATIC REVIEW;

EID: 33845673560     PISSN: 09680160     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.knee.2006.10.006     Document Type: Review
Times cited : (84)

References (56)
  • 1
    • 27744465227 scopus 로고    scopus 로고
    • Cochrane Handbook for Systematic Reviews of Interventions 4.2.5 [updated May 2005]
    • Wiley, Chichester
    • Green S., and Higgins J.P.T. Cochrane Handbook for Systematic Reviews of Interventions 4.2.5 [updated May 2005]. The Cochrane Library Issue 3 (2005), Wiley, Chichester
    • (2005) The Cochrane Library , vol.Issue 3
    • Green, S.1    Higgins, J.P.T.2
  • 2
    • 0002666222 scopus 로고
    • Assessment of joint motion
    • Rothstein J.M. (Ed), Churchill Livingstone, London
    • Miller P.J. Assessment of joint motion. In: Rothstein J.M. (Ed). Measurement in physical therapy (1985), Churchill Livingstone, London
    • (1985) Measurement in physical therapy
    • Miller, P.J.1
  • 3
    • 0020514697 scopus 로고
    • Goniometric reliability in a clinical setting: elbow and knee measurements
    • Rothstein J.M., Miller P.J., and Roettger R.F. Goniometric reliability in a clinical setting: elbow and knee measurements. Phys Ther 63 (1983) 1611-1615
    • (1983) Phys Ther , vol.63 , pp. 1611-1615
    • Rothstein, J.M.1    Miller, P.J.2    Roettger, R.F.3
  • 4
    • 0021349407 scopus 로고
    • Realibility of joint angle measurement: discussion of methodology issues
    • Stratford P., Agostino V., Brazeau C., and Gowitzke B.A. Realibility of joint angle measurement: discussion of methodology issues. Physiother Can 36 (1984) 5-9
    • (1984) Physiother Can , vol.36 , pp. 5-9
    • Stratford, P.1    Agostino, V.2    Brazeau, C.3    Gowitzke, B.A.4
  • 5
    • 2942618402 scopus 로고    scopus 로고
    • Factors affecting interpretation of reliability coefficients
    • Russek L. Factors affecting interpretation of reliability coefficients. J Orthop Sport Phys Ther 34 (2004) 341-349
    • (2004) J Orthop Sport Phys Ther , vol.34 , pp. 341-349
    • Russek, L.1
  • 6
    • 0023609042 scopus 로고
    • Clinical measurement of range of motion: review of goniometry emphasizing reliability and reliability
    • Gajdosik R.L., and Bohannon R.W. Clinical measurement of range of motion: review of goniometry emphasizing reliability and reliability. Phys Ther 67 (1987) 1867-1872
    • (1987) Phys Ther , vol.67 , pp. 1867-1872
    • Gajdosik, R.L.1    Bohannon, R.W.2
  • 7
    • 0026058416 scopus 로고
    • Reliability of goniometric measurements and visual estimates of knee range of motion obtained in a clinical setting
    • Watkins M.A., Riddle D.L., Lamb R.L., and Personius W.J. Reliability of goniometric measurements and visual estimates of knee range of motion obtained in a clinical setting. Phys Ther 71 (1991) 90-96
    • (1991) Phys Ther , vol.71 , pp. 90-96
    • Watkins, M.A.1    Riddle, D.L.2    Lamb, R.L.3    Personius, W.J.4
  • 8
    • 0024216607 scopus 로고
    • Intertester reliability and concurrent validity of fluid-based and universal goniometers for active knee flexion
    • Rheault W., Miller M., Nothnagel P., Straessle J., and Urban D. Intertester reliability and concurrent validity of fluid-based and universal goniometers for active knee flexion. Phys Ther 68 (1988) 1676-1678
    • (1988) Phys Ther , vol.68 , pp. 1676-1678
    • Rheault, W.1    Miller, M.2    Nothnagel, P.3    Straessle, J.4    Urban, D.5
  • 9
    • 0035107531 scopus 로고    scopus 로고
    • Interrater reliability of the active-knee-extension test for hamstring length in school-aged children
    • Rakos D.M., Shaw K.A., Fedor R.L., LaManna M., Yocum C.C., and Lawrence K.J. Interrater reliability of the active-knee-extension test for hamstring length in school-aged children. Pediatr Phys Ther 13 (2001) 37-41
    • (2001) Pediatr Phys Ther , vol.13 , pp. 37-41
    • Rakos, D.M.1    Shaw, K.A.2    Fedor, R.L.3    LaManna, M.4    Yocum, C.C.5    Lawrence, K.J.6
  • 10
    • 0142152685 scopus 로고    scopus 로고
    • Can the Internet be used as a medium to evaluate knee angle?
    • Russell T.G., Jull G.A., and Wootton R. Can the Internet be used as a medium to evaluate knee angle?. Man Ther 8 (2003) 242-246
    • (2003) Man Ther , vol.8 , pp. 242-246
    • Russell, T.G.1    Jull, G.A.2    Wootton, R.3
  • 11
    • 0035092709 scopus 로고    scopus 로고
    • Intra- and intertester reliability and criterion validity of the parallelogram and universal goniometers for measuring maximum active knee flexion and extension of patients with knee restrictions
    • Brosseau L., Balmer S., Tousignant M., O'Sullivan J.P., Goudreault C., Goudreault M., et al. Intra- and intertester reliability and criterion validity of the parallelogram and universal goniometers for measuring maximum active knee flexion and extension of patients with knee restrictions. Arch Phys Med Rehabil 82 (2001) 396-402
    • (2001) Arch Phys Med Rehabil , vol.82 , pp. 396-402
    • Brosseau, L.1    Balmer, S.2    Tousignant, M.3    O'Sullivan, J.P.4    Goudreault, C.5    Goudreault, M.6
  • 12
    • 0031296751 scopus 로고    scopus 로고
    • Intratester and intertester reliability and criterion validity of the parallelogram and universal goniometers for active knee flexion in healthy subjects
    • Brosseau L., Tousignant M., Budd J., Chartier N., Duciaume L., Plamondon S., et al. Intratester and intertester reliability and criterion validity of the parallelogram and universal goniometers for active knee flexion in healthy subjects. Physiother Res Int 2 (1997) 150-166
    • (1997) Physiother Res Int , vol.2 , pp. 150-166
    • Brosseau, L.1    Tousignant, M.2    Budd, J.3    Chartier, N.4    Duciaume, L.5    Plamondon, S.6
  • 14
    • 0037860576 scopus 로고    scopus 로고
    • Reliability of photographic range of motion measurements in a healthy sample: knee and ankle joint measurement
    • Karkouti E., and Marks R. Reliability of photographic range of motion measurements in a healthy sample: knee and ankle joint measurement. Physiother Can 49 (1997) 24-31
    • (1997) Physiother Can , vol.49 , pp. 24-31
    • Karkouti, E.1    Marks, R.2
  • 15
    • 0030321553 scopus 로고    scopus 로고
    • Evaluation of the reliability of reflective marker placements
    • Marks R., and Karkouti E. Evaluation of the reliability of reflective marker placements. Physiother Res Int 1 (1996) 50-61
    • (1996) Physiother Res Int , vol.1 , pp. 50-61
    • Marks, R.1    Karkouti, E.2
  • 16
    • 0023854164 scopus 로고
    • Comparison of the reliability of the Orthoranger and the standard goniometer for assessing active lower extremity range of motion
    • Clapper M.P., and Wolf S.L. Comparison of the reliability of the Orthoranger and the standard goniometer for assessing active lower extremity range of motion. Phys Ther 68 (1988) 214-218
    • (1988) Phys Ther , vol.68 , pp. 214-218
    • Clapper, M.P.1    Wolf, S.L.2
  • 18
    • 0242432353 scopus 로고    scopus 로고
    • The use of sequential MR image sets for determining tibiofemoral motion: reliability of coordinate systems and accuracy of motion tracking algorithm
    • Lerner A.L., Tamez-Pena J.G., Houck J.R., Yao J., Harmon H.L., Salo A.D., et al. The use of sequential MR image sets for determining tibiofemoral motion: reliability of coordinate systems and accuracy of motion tracking algorithm. J Biomech Eng 125 (2003) 246-253
    • (2003) J Biomech Eng , vol.125 , pp. 246-253
    • Lerner, A.L.1    Tamez-Pena, J.G.2    Houck, J.R.3    Yao, J.4    Harmon, H.L.5    Salo, A.D.6
  • 19
    • 0034854181 scopus 로고    scopus 로고
    • Validation of flexible electrogoniometry as a measure of joint kinematics
    • Rowe P.J., Myles C.M., Hillmann S.J., and Hazlewood M.E. Validation of flexible electrogoniometry as a measure of joint kinematics. Physiotherapy 87 (2001) 479-488
    • (2001) Physiotherapy , vol.87 , pp. 479-488
    • Rowe, P.J.1    Myles, C.M.2    Hillmann, S.J.3    Hazlewood, M.E.4
  • 20
    • 0030859787 scopus 로고    scopus 로고
    • Repeated measures of adult normal walking using a video tracking system
    • Growney E., Meglan D., Johnson M., Cahalan T., and An K.N. Repeated measures of adult normal walking using a video tracking system. Gait Posture 6 (1997) 147-162
    • (1997) Gait Posture , vol.6 , pp. 147-162
    • Growney, E.1    Meglan, D.2    Johnson, M.3    Cahalan, T.4    An, K.N.5
  • 21
    • 0022516387 scopus 로고
    • Three-dimensional electrogoniometric gait recording
    • Isacson J., Gransberg L., and Knutsson E. Three-dimensional electrogoniometric gait recording. J Biomech 19 (1986) 627-635
    • (1986) J Biomech , vol.19 , pp. 627-635
    • Isacson, J.1    Gransberg, L.2    Knutsson, E.3
  • 22
    • 0020567239 scopus 로고
    • Normative data of knee joint motion and ground reaction force in adult level walking
    • Chao E.Y., Laughman R.K., Schneider S.S., and Stauffer R.N. Normative data of knee joint motion and ground reaction force in adult level walking. J Biomech 16 (1983) 219-233
    • (1983) J Biomech , vol.16 , pp. 219-233
    • Chao, E.Y.1    Laughman, R.K.2    Schneider, S.S.3    Stauffer, R.N.4
  • 23
    • 0032170201 scopus 로고    scopus 로고
    • Validity and reliability of measurements taken by the Peak 5 motion analysis system
    • Selfe J. Validity and reliability of measurements taken by the Peak 5 motion analysis system. J Med Eng Technol 22 (1998) 220-225
    • (1998) J Med Eng Technol , vol.22 , pp. 220-225
    • Selfe, J.1
  • 24
    • 0025374717 scopus 로고
    • Reliability of a clinical kinematic assessment of the sit-to-stand movement
    • Jeng S.F., Schenkman M., Riley P.O., and Lin S.J. Reliability of a clinical kinematic assessment of the sit-to-stand movement. Phys Ther 70 (1990) 511-520
    • (1990) Phys Ther , vol.70 , pp. 511-520
    • Jeng, S.F.1    Schenkman, M.2    Riley, P.O.3    Lin, S.J.4
  • 25
    • 0022456504 scopus 로고
    • Radiographic verification of knee goniometry
    • Enwemeka C.S. Radiographic verification of knee goniometry. Scand J Rehabil Med 18 (1986) 47-49
    • (1986) Scand J Rehabil Med , vol.18 , pp. 47-49
    • Enwemeka, C.S.1
  • 26
    • 0006155501 scopus 로고
    • Validity and intertester reliability of static joint angle measurements made with the PEAK5 motion analysis system
    • Bratton C.V., and Ross E.C. Validity and intertester reliability of static joint angle measurements made with the PEAK5 motion analysis system. Phys Ther 74 (1994) S113
    • (1994) Phys Ther , vol.74
    • Bratton, C.V.1    Ross, E.C.2
  • 28
    • 0038287989 scopus 로고    scopus 로고
    • Intrarater reliability of lower limb sagittal range-of-motion measures in children with spastic diplegia
    • Kilgour G., McNair P., and Stott S.N. Intrarater reliability of lower limb sagittal range-of-motion measures in children with spastic diplegia. Dev Med Child Neurol 45 (2003) 391-399
    • (2003) Dev Med Child Neurol , vol.45 , pp. 391-399
    • Kilgour, G.1    McNair, P.2    Stott, S.N.3
  • 29
    • 0032904852 scopus 로고    scopus 로고
    • Repeatability of goniometer measurements of the knee in patients wearing an Ilizarov external fixator: a clinic-based study
    • Barker K.L., Lamb S.E., Burns M., and Simpson A.H.R. Repeatability of goniometer measurements of the knee in patients wearing an Ilizarov external fixator: a clinic-based study. Clin Rehabil 13 (1999) 156-163
    • (1999) Clin Rehabil , vol.13 , pp. 156-163
    • Barker, K.L.1    Lamb, S.E.2    Burns, M.3    Simpson, A.H.R.4
  • 30
    • 0021368263 scopus 로고
    • Goniometric measurement reliability in physical medicine
    • Mayerson N.H., and Milano R.A. Goniometric measurement reliability in physical medicine. Arch Phys Med Rehabil 65 (1984) 92-94
    • (1984) Arch Phys Med Rehabil , vol.65 , pp. 92-94
    • Mayerson, N.H.1    Milano, R.A.2
  • 31
    • 0023096476 scopus 로고
    • Reliability and validity of goniometric measurements at the knee
    • Gogia P.P., Braatz J.H., Rose S.J., and Norton B.J. Reliability and validity of goniometric measurements at the knee. Phys Ther 67 (1987) 192-195
    • (1987) Phys Ther , vol.67 , pp. 192-195
    • Gogia, P.P.1    Braatz, J.H.2    Rose, S.J.3    Norton, B.J.4
  • 32
    • 0031916044 scopus 로고    scopus 로고
    • Comparison of a new linear instrument and the gravity goniometer for assessing knee extension ROM among children
    • Hein V. Comparison of a new linear instrument and the gravity goniometer for assessing knee extension ROM among children. J Sport Rehabil 7 (1998) 61-68
    • (1998) J Sport Rehabil , vol.7 , pp. 61-68
    • Hein, V.1
  • 33
    • 21644445549 scopus 로고    scopus 로고
    • Reliability of upper and lower limb three-dimensional kinematics in children with hemiplegia
    • Mackey A.H., Walt S.E., Lobb G.A., and Stott N.S. Reliability of upper and lower limb three-dimensional kinematics in children with hemiplegia. Gait Posture 22 (2005) 1-9
    • (2005) Gait Posture , vol.22 , pp. 1-9
    • Mackey, A.H.1    Walt, S.E.2    Lobb, G.A.3    Stott, N.S.4
  • 34
    • 0023719630 scopus 로고
    • Reliability of goniometric measurements of children with cerebral palsy
    • Stuberg W.A., Fuchs R.H., and Miedaner J.A. Reliability of goniometric measurements of children with cerebral palsy. Dev Med Child Neurol 30 (1988) 657-666
    • (1988) Dev Med Child Neurol , vol.30 , pp. 657-666
    • Stuberg, W.A.1    Fuchs, R.H.2    Miedaner, J.A.3
  • 35
    • 0033962146 scopus 로고    scopus 로고
    • Intrasubject repeatability of gait analysis data in normal and spastic children
    • Steinwender G., Saraph V., Scheiber S., Zwick E.B., Uitz C., and Hackl K. Intrasubject repeatability of gait analysis data in normal and spastic children. Clin Biomech 15 (2000) 134-139
    • (2000) Clin Biomech , vol.15 , pp. 134-139
    • Steinwender, G.1    Saraph, V.2    Scheiber, S.3    Zwick, E.B.4    Uitz, C.5    Hackl, K.6
  • 36
    • 18844382124 scopus 로고    scopus 로고
    • Reliability and validity of a 2-D video digitizing system during a static and a dynamic task
    • Gribble P., Hertel J., Denegar C., and Buckley W. Reliability and validity of a 2-D video digitizing system during a static and a dynamic task. J Sport Rehabil 14 (2005) 137-149
    • (2005) J Sport Rehabil , vol.14 , pp. 137-149
    • Gribble, P.1    Hertel, J.2    Denegar, C.3    Buckley, W.4
  • 37
    • 0020615699 scopus 로고
    • Hamstring muscle tightness. Reliability of an active-knee-extension test
    • Gajdosik R., and Lusin G. Hamstring muscle tightness. Reliability of an active-knee-extension test. Phys Ther 63 (1983) 1085-1090
    • (1983) Phys Ther , vol.63 , pp. 1085-1090
    • Gajdosik, R.1    Lusin, G.2
  • 39
    • 0028309893 scopus 로고
    • Joint mobility measurements: reliability of a standardized method
    • Dijkstra P.U., de Bont L.G., van der Weele L.T., and Boering G. Joint mobility measurements: reliability of a standardized method. Cranio 12 (1994) 52-57
    • (1994) Cranio , vol.12 , pp. 52-57
    • Dijkstra, P.U.1    de Bont, L.G.2    van der Weele, L.T.3    Boering, G.4
  • 41
    • 0037710121 scopus 로고    scopus 로고
    • Repeatability of gait data using a functional hip joint centre and a mean helical knee axis
    • Besier T.F., Sturnieks D.L., Alderson J.A., and Lloyd D.G. Repeatability of gait data using a functional hip joint centre and a mean helical knee axis. J Biomech 36 (2003)
    • (2003) J Biomech , vol.36
    • Besier, T.F.1    Sturnieks, D.L.2    Alderson, J.A.3    Lloyd, D.G.4
  • 42
    • 0020046041 scopus 로고
    • Lower extremity goniometric measurements: a study to determine their reliability
    • Ekstrand J., Wiktorsson M., Oberg B., and Gillquist J. Lower extremity goniometric measurements: a study to determine their reliability. Arch Phys Med Rehabil 63 (1982) 171-175
    • (1982) Arch Phys Med Rehabil , vol.63 , pp. 171-175
    • Ekstrand, J.1    Wiktorsson, M.2    Oberg, B.3    Gillquist, J.4
  • 43
    • 0029329207 scopus 로고
    • Flexible electrogoniometers: kinesiological advantages with respect to potentiometric goniometers
    • Tesio L., Monzani M., Gatti R., and Franchignoni F. Flexible electrogoniometers: kinesiological advantages with respect to potentiometric goniometers. Clin Biomech 10 (1995) 275-277
    • (1995) Clin Biomech , vol.10 , pp. 275-277
    • Tesio, L.1    Monzani, M.2    Gatti, R.3    Franchignoni, F.4
  • 44
    • 0025063714 scopus 로고
    • Real-time gait assessment utilizing a new way of accelerometry
    • Willemsen A.T., van Alste J.A., and Boom H.B. Real-time gait assessment utilizing a new way of accelerometry. J Biomech 23 (1990) 859-863
    • (1990) J Biomech , vol.23 , pp. 859-863
    • Willemsen, A.T.1    van Alste, J.A.2    Boom, H.B.3
  • 45
    • 0032860487 scopus 로고    scopus 로고
    • Effects of static and hold-relax stretching on hamstring range of motion using the FlexAbility LE1000
    • Gribble P.A., Guskiewicz K.M., Prentice W.E., and Shields E.W. Effects of static and hold-relax stretching on hamstring range of motion using the FlexAbility LE1000. J Sport Rehabil 8 (1999) 195-208
    • (1999) J Sport Rehabil , vol.8 , pp. 195-208
    • Gribble, P.A.1    Guskiewicz, K.M.2    Prentice, W.E.3    Shields, E.W.4
  • 46
    • 0347931717 scopus 로고    scopus 로고
    • Validity and comparisons of tibiofemoral orientations and displacement using a femoral tracking device during early to mid stance of walking
    • Houck J., Yack H.J., and Cuddeford T. Validity and comparisons of tibiofemoral orientations and displacement using a femoral tracking device during early to mid stance of walking. Gait Posture 19 (2004) 76-84
    • (2004) Gait Posture , vol.19 , pp. 76-84
    • Houck, J.1    Yack, H.J.2    Cuddeford, T.3
  • 47
    • 23844513274 scopus 로고    scopus 로고
    • A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes
    • Dejnabadi H., Jolles B.M., and Aminian K. A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes. IEEE Trans Biomed Eng 52 (2005) 1478-1484
    • (2005) IEEE Trans Biomed Eng , vol.52 , pp. 1478-1484
    • Dejnabadi, H.1    Jolles, B.M.2    Aminian, K.3
  • 51
    • 0035145672 scopus 로고    scopus 로고
    • Correcting out-of-plane errors in two-dimensional imaging using nonimage-related information
    • Sih B.L., Hubbard M., and Williams K.R. Correcting out-of-plane errors in two-dimensional imaging using nonimage-related information. J Biomech 34 (2001) 257-260
    • (2001) J Biomech , vol.34 , pp. 257-260
    • Sih, B.L.1    Hubbard, M.2    Williams, K.R.3
  • 52
    • 0009590651 scopus 로고
    • Optical methods: errors in two-dimensional motion analysis
    • Nigg B.M., and Herzog W. (Eds), Wiley, New York
    • Nigg B.M., and Cole G.K. Optical methods: errors in two-dimensional motion analysis. In: Nigg B.M., and Herzog W. (Eds). Biomechanics of the musculo-skeletal system (1994), Wiley, New York 283-284
    • (1994) Biomechanics of the musculo-skeletal system , pp. 283-284
    • Nigg, B.M.1    Cole, G.K.2
  • 53
    • 0028040599 scopus 로고
    • Statistical methodology for the concurrent assessment of interrater and intrarater reliability: using goniometric measurements as an example
    • Eliasziw M., Young S.L., Woodbury M.G., and Fryday-Field K. Statistical methodology for the concurrent assessment of interrater and intrarater reliability: using goniometric measurements as an example. Phys Ther 74 (1994) 777-788
    • (1994) Phys Ther , vol.74 , pp. 777-788
    • Eliasziw, M.1    Young, S.L.2    Woodbury, M.G.3    Fryday-Field, K.4
  • 54
    • 3042581979 scopus 로고    scopus 로고
    • Computerized biofeedback knee goniometer: acceptance and effect on exercise behavior in post-total knee arthroplasty rehabilitation
    • Kuiken T.A., Amir H., and Scheidt R.A. Computerized biofeedback knee goniometer: acceptance and effect on exercise behavior in post-total knee arthroplasty rehabilitation. Arch Phys Med Rehabil 85 (2004) 1026-1030
    • (2004) Arch Phys Med Rehabil , vol.85 , pp. 1026-1030
    • Kuiken, T.A.1    Amir, H.2    Scheidt, R.A.3
  • 55
    • 0032411404 scopus 로고    scopus 로고
    • A point cluster method for in vivo motion analysis: applied to a study of knee kinematics
    • Andriacchi T.P., Alexander E.J., Toney M.K., Dyrby C., and Sum J. A point cluster method for in vivo motion analysis: applied to a study of knee kinematics. J Biomech Eng 120 (1998) 743-749
    • (1998) J Biomech Eng , vol.120 , pp. 743-749
    • Andriacchi, T.P.1    Alexander, E.J.2    Toney, M.K.3    Dyrby, C.4    Sum, J.5
  • 56
    • 0025859854 scopus 로고
    • A finite helical axis as a landmark for kinematic reference of the knee
    • Hart R.A., Mote C.D., and Skinner H.B. A finite helical axis as a landmark for kinematic reference of the knee. J Biomech Eng 113 (1991) 215-222
    • (1991) J Biomech Eng , vol.113 , pp. 215-222
    • Hart, R.A.1    Mote, C.D.2    Skinner, H.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.