메뉴 건너뛰기




Volumn 14, Issue 1, 2007, Pages 46-50

Biomechanical evaluation of different fixation plates in medial opening upper tibial osteotomy

Author keywords

Biomechanics; High tibial osteotomy; Knee; Plate designs; Proximal tibial osteotomy; Unicompartmental osteoarthritis

Indexed keywords

ANIMAL TISSUE; ARTICLE; BIOMECHANICS; BONE PLATE; BONE SCREW; CATTLE; COMPARATIVE STUDY; COMPRESSION; FORCE; MALE; MODEL; NONHUMAN; PRIORITY JOURNAL; RUNNING; TIBIA; TIBIA OSTEOTOMY; WALKING; WEIGHT BEARING;

EID: 33845652532     PISSN: 09680160     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.knee.2006.10.003     Document Type: Article
Times cited : (11)

References (24)
  • 1
    • 29244431779 scopus 로고    scopus 로고
    • Osteotomy about the knee: American perspective
    • Insall J.M., and Scott N.M. (Eds), Churchill Livingstone
    • Hanssen A. Osteotomy about the knee: American perspective. In: Insall J.M., and Scott N.M. (Eds). Surgery of the knee (2001), Churchill Livingstone 1447-1464
    • (2001) Surgery of the knee , pp. 1447-1464
    • Hanssen, A.1
  • 3
    • 0035013166 scopus 로고    scopus 로고
    • Open wedge tibial osteotomy by hemicallotasis for medial compartment osteoarthritis
    • Klinger H.M., Lorenz F., and Harer T. Open wedge tibial osteotomy by hemicallotasis for medial compartment osteoarthritis. Arch Orthop Trauma Surg 121 (2001) 245-247
    • (2001) Arch Orthop Trauma Surg , vol.121 , pp. 245-247
    • Klinger, H.M.1    Lorenz, F.2    Harer, T.3
  • 4
    • 0033958798 scopus 로고    scopus 로고
    • High tibial osteotomy with a calibrated osteotomy guide, rigid internal fixation, and early motion: long-term follow-up
    • Billings A., Scott D.F., Camargo M.P., and Hofmann A.A. High tibial osteotomy with a calibrated osteotomy guide, rigid internal fixation, and early motion: long-term follow-up. J Bone Joint Surg Am 82 (2000) 70-79
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 70-79
    • Billings, A.1    Scott, D.F.2    Camargo, M.P.3    Hofmann, A.A.4
  • 5
    • 33644692036 scopus 로고    scopus 로고
    • Fixation of proximal tibia medial opening wedge osteotomy using plates with wedges
    • [Article in Turkish]
    • Esenkaya I. Fixation of proximal tibia medial opening wedge osteotomy using plates with wedges. Acta Orthop Traumatol Turc 39 (2005) 211-223 [Article in Turkish]
    • (2005) Acta Orthop Traumatol Turc , vol.39 , pp. 211-223
    • Esenkaya, I.1
  • 6
    • 33749354325 scopus 로고    scopus 로고
    • Proximal tibia medial open-wedge osteotomy using plates with wedges: early results in 58 cases
    • Esenkaya I., and Elmali N. Proximal tibia medial open-wedge osteotomy using plates with wedges: early results in 58 cases. Knee Surg Sports Traumatol Arthrosc 14 (2006) 955-961
    • (2006) Knee Surg Sports Traumatol Arthrosc , vol.14 , pp. 955-961
    • Esenkaya, I.1    Elmali, N.2
  • 7
    • 0032693161 scopus 로고    scopus 로고
    • Primary stability of different implants used in conjunction with high tibial osteotomy
    • Flamme C.H., Kohn D., Kirsch L., and Hurschler C. Primary stability of different implants used in conjunction with high tibial osteotomy. Arch Orthop Trauma Surg 119 (19994) 450-459
    • Arch Orthop Trauma Surg , vol.119 , pp. 450-459
    • Flamme, C.H.1    Kohn, D.2    Kirsch, L.3    Hurschler, C.4
  • 9
    • 0023181959 scopus 로고
    • Proksimal tibial osteotomy for osteoarthritis with varus deformity: a ten to thirteen-year follow-up study
    • Hernigou P.H., Medevielle D., Debeyre J., and Goutallier D. Proksimal tibial osteotomy for osteoarthritis with varus deformity: a ten to thirteen-year follow-up study. J Bone Joint Surg Am 69 (1987) 332-354
    • (1987) J Bone Joint Surg Am , vol.69 , pp. 332-354
    • Hernigou, P.H.1    Medevielle, D.2    Debeyre, J.3    Goutallier, D.4
  • 10
    • 0026329988 scopus 로고
    • High tibial osteotomy: Use of an osteotomy jig, rigid fixation, and early motion versus conventional surgical technique and cast immobilization
    • Hofmann A.A., Wyatt R.W., and Beck S.W. High tibial osteotomy: Use of an osteotomy jig, rigid fixation, and early motion versus conventional surgical technique and cast immobilization. Clin Orthop 271 (1991) 212-217
    • (1991) Clin Orthop , vol.271 , pp. 212-217
    • Hofmann, A.A.1    Wyatt, R.W.2    Beck, S.W.3
  • 11
    • 0024550355 scopus 로고
    • High tibial osteotomy with fixation by a blade plate for medial compartment osteoarthritis of the knee
    • Koshino T., Morii T., Wada J., Saito H., Ozawa N., and Noyori K. High tibial osteotomy with fixation by a blade plate for medial compartment osteoarthritis of the knee. Orthop Clin North Am 20 (1989) 227-243
    • (1989) Orthop Clin North Am , vol.20 , pp. 227-243
    • Koshino, T.1    Morii, T.2    Wada, J.3    Saito, H.4    Ozawa, N.5    Noyori, K.6
  • 12
    • 0037267443 scopus 로고    scopus 로고
    • Medial opening-wedge high tibial osteotomy with use of porous hydroxyapatite to treat medial compartment osteoarthritis of the knee
    • Koshino T., Murase T., and Saito T. Medial opening-wedge high tibial osteotomy with use of porous hydroxyapatite to treat medial compartment osteoarthritis of the knee. J Bone Joint Surg Am 85 (2003) 78-85
    • (2003) J Bone Joint Surg Am , vol.85 , pp. 78-85
    • Koshino, T.1    Murase, T.2    Saito, T.3
  • 14
    • 0142161636 scopus 로고    scopus 로고
    • Open-wedge high tibial osteotomy with rigid plate fixation
    • Lobenhoffer P., De Simoni C., and Staubli A.E. Open-wedge high tibial osteotomy with rigid plate fixation. Tech Knee Surg 1 (2002) 93-105
    • (2002) Tech Knee Surg , vol.1 , pp. 93-105
    • Lobenhoffer, P.1    De Simoni, C.2    Staubli, A.E.3
  • 16
    • 31544472827 scopus 로고    scopus 로고
    • Biomechanical investigations of different internal fixations in medial opening-wedge high tibial osteotomy
    • Spahn G., Muckley T., Kahl E., and Hofmann G.O. Biomechanical investigations of different internal fixations in medial opening-wedge high tibial osteotomy. Clin Biomech (Bristol Avon) 21 (2006) 272-278
    • (2006) Clin Biomech (Bristol Avon) , vol.21 , pp. 272-278
    • Spahn, G.1    Muckley, T.2    Kahl, E.3    Hofmann, G.O.4
  • 17
    • 0036911344 scopus 로고    scopus 로고
    • Primary stability of various implants in tibial opening wedge osteotomy: a biomechanical study
    • Spahn G., and Wittig R. Primary stability of various implants in tibial opening wedge osteotomy: a biomechanical study. J Orthop Sci 7 (2002) 683-687
    • (2002) J Orthop Sci , vol.7 , pp. 683-687
    • Spahn, G.1    Wittig, R.2
  • 19
    • 4744356841 scopus 로고    scopus 로고
    • Open wedge high tibial osteotomy: biomechanical investigation of the modified arthrex osteotomy plate (Puddu Plate) and the Tomofix Plate
    • Stoffel K., Stachowiak G., and Kuster M. Open wedge high tibial osteotomy: biomechanical investigation of the modified arthrex osteotomy plate (Puddu Plate) and the Tomofix Plate. Clin Biomech 19 (2004) 944-950
    • (2004) Clin Biomech , vol.19 , pp. 944-950
    • Stoffel, K.1    Stachowiak, G.2    Kuster, M.3
  • 20
    • 0033145047 scopus 로고    scopus 로고
    • Biomechanical evaluation of a proximal tibial opening wedge osteotomy plate
    • Stuart M.J., Beachy A.M., Grabowski J.J., An K.N., and Kaufman K.R. Biomechanical evaluation of a proximal tibial opening wedge osteotomy plate. Am J Knee Surg 12 (1999) 148-153
    • (1999) Am J Knee Surg , vol.12 , pp. 148-153
    • Stuart, M.J.1    Beachy, A.M.2    Grabowski, J.J.3    An, K.N.4    Kaufman, K.R.5
  • 21
    • 33646175585 scopus 로고    scopus 로고
    • Biomechanical stability of a retrotubercle opening wedge high tibial osteotomy
    • Zhim F., Laflamme G.Y., Viens H., Laflamme G.H., and Yahia L. Biomechanical stability of a retrotubercle opening wedge high tibial osteotomy. J Knee Surg 19 (2006) 28-32
    • (2006) J Knee Surg , vol.19 , pp. 28-32
    • Zhim, F.1    Laflamme, G.Y.2    Viens, H.3    Laflamme, G.H.4    Yahia, L.5
  • 22
    • 33746350757 scopus 로고    scopus 로고
    • A new distractor with angle-scale for proximal tibia medial opening wedge osteotomy
    • Esenkaya I. A new distractor with angle-scale for proximal tibia medial opening wedge osteotomy. Knee Surg Sports Traumatol Arthrosc 14 (2006) 443-446
    • (2006) Knee Surg Sports Traumatol Arthrosc , vol.14 , pp. 443-446
    • Esenkaya, I.1
  • 24
    • 0014698584 scopus 로고
    • The mechanics of the knee joint in relation to normal walking
    • Morrison J.B. The mechanics of the knee joint in relation to normal walking. J Biomech 3 (1970) 51-61
    • (1970) J Biomech , vol.3 , pp. 51-61
    • Morrison, J.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.