Volumn 43, Issue 2, 2007, Pages 631-645
|
Method development for dihydralazine with HPLC-MS/MS-an old but tricky substance in human plasma
|
Author keywords
1,4 Dithiothreitol (DTT) as stabilizer; Degradation of dihydralazine; Dihydralazine; Human plasma; Liquid chromatography mass spectrometry
|
Indexed keywords
ALDEHYDE;
DIHYDRALAZINE;
DITHIOTHREITOL;
HYDRAZINE;
KETONE;
PROTEIN;
STABILIZING AGENT;
ACCURACY;
ARTICLE;
BLOOD SAMPLING;
CALIBRATION;
COOLING;
DECOMPOSITION;
DRUG DEGRADATION;
DRUG DETERMINATION;
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY;
HUMAN;
PLASMA;
PRECIPITATION;
PRIORITY JOURNAL;
QUALITY CONTROL;
SENSITIVITY AND SPECIFICITY;
TANDEM MASS SPECTROMETRY;
ANTIHYPERTENSIVE AGENTS;
BIOLOGICAL AVAILABILITY;
CHROMATOGRAPHY, HIGH PRESSURE LIQUID;
CROSS-OVER STUDIES;
DIHYDRALAZINE;
DITHIOTHREITOL;
DRUG STABILITY;
HUMANS;
LINEAR MODELS;
QUALITY CONTROL;
REDUCING AGENTS;
REFERENCE VALUES;
REPRODUCIBILITY OF RESULTS;
SENSITIVITY AND SPECIFICITY;
TANDEM MASS SPECTROMETRY;
TEMPERATURE;
TIME FACTORS;
|
EID: 33845644741
PISSN: 07317085
EISSN: None
Source Type: Journal
DOI: 10.1016/j.jpba.2006.07.041 Document Type: Article |
Times cited : (6)
|
References (5)
|