메뉴 건너뛰기




Volumn 19, Issue 6, 2006, Pages 574-576

A preliminary in vivo trial of load transfer in mandibular implant-retained overdentures anchored in 2 different ways: Allowing and counteracting free rotation

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; DENTURE; HUMAN; MANDIBLE; MASTICATION; MATERIALS TESTING; MECHANICAL STRESS; MOUTH MUCOSA; PHYSIOLOGY; PILOT STUDY; PRESSURE TRANSDUCER; ROTATION; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 33845641306     PISSN: 08932174     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (26)

References (5)
  • 1
    • 0027347336 scopus 로고
    • Osseointegrated dental implants with ball attachments supporting overdentures in patients with mandibular alveolar ridge atrophy
    • Donatsky O. Osseointegrated dental implants with ball attachments supporting overdentures in patients with mandibular alveolar ridge atrophy. Int J Oral Maxillofac Implants 1993;8:162-166.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 162-166
    • Donatsky, O.1
  • 2
    • 0034157335 scopus 로고    scopus 로고
    • Implant-supported mandibular overdentures retained with ball or bar attachments: A randomized prospective 5-year study
    • Gotfredsen K, Holm B. Implant-supported mandibular overdentures retained with ball or bar attachments: A randomized prospective 5-year study. Int J Prosthodont 2000;13:125-130.
    • (2000) Int J Prosthodont , vol.13 , pp. 125-130
    • Gotfredsen, K.1    Holm, B.2
  • 3
    • 0035502393 scopus 로고    scopus 로고
    • A longitudinal study on mandibular implants supporting an overdenture: The influence of retention mechanism and anatomic-prosthetic variables on peri-implant parameters
    • Oetterli M, Kiener P, Mericske-Stern R. A longitudinal study on mandibular implants supporting an overdenture: The influence of retention mechanism and anatomic-prosthetic variables on peri-implant parameters. Int J Prosthodont 2001;14:536-542.
    • (2001) Int J Prosthodont , vol.14 , pp. 536-542
    • Oetterli, M.1    Kiener, P.2    Mericske-Stern, R.3
  • 4
    • 0035489302 scopus 로고    scopus 로고
    • Orientation of retentive matrices on spherical attachments independent of implant parallelism
    • Wiemeyer AS, Agar JR, Kazemi RB. Orientation of retentive matrices on spherical attachments independent of implant parallelism. J Prosthet Dent 2001;86:434-437.
    • (2001) J Prosthet Dent , vol.86 , pp. 434-437
    • Wiemeyer, A.S.1    Agar, J.R.2    Kazemi, R.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.