메뉴 건너뛰기




Volumn 29, Issue 1, 2007, Pages 149-155

A new antibody immobilization strategy based on electro-deposition of gold nanoparticles and Prussian Blue for label-free amperometric immunosensor

Author keywords

Amperometric immunosensor; Electro deposition; Gold nanoparticle; Hepatitis B surface antigen; Prussian Blue

Indexed keywords

BIOSENSORS; ELECTRODEPOSITION; GOLD COMPOUNDS; IMMUNOLOGY; NANOSTRUCTURED MATERIALS;

EID: 33845631600     PISSN: 01415492     EISSN: 15736776     Source Type: Journal    
DOI: 10.1007/s10529-006-9211-7     Document Type: Article
Times cited : (31)

References (11)
  • 1
    • 0031571838 scopus 로고    scopus 로고
    • Capacitance measurements of antibody-antigen interactions in a flow system
    • Berggren C, Johansson G (1997) Capacitance measurements of antibody-antigen interactions in a flow system. Anal Chem 69:3651-3657
    • (1997) Anal Chem , vol.69 , pp. 3651-3657
    • Berggren, C.1    Johansson, G.2
  • 2
    • 27144446136 scopus 로고    scopus 로고
    • Impedance immunosensor based on receptor protein adsorbed directly on porous gold film
    • Chen ZP, Jiang JH, Shen GL, Yu RQ (2005) Impedance immunosensor based on receptor protein adsorbed directly on porous gold film. Anal Chim Acta 553:190-195
    • (2005) Anal Chim Acta , vol.553 , pp. 190-195
    • Chen, Z.P.1    Jiang, J.H.2    Shen, G.L.3    Yu, R.Q.4
  • 3
    • 0032634057 scopus 로고    scopus 로고
    • Operational stability of amperometric hydrogen peroxide sensors, based on ferrous and copper hexacyanoferrates
    • Garjonyte R, Malinauskas A (1999) Operational stability of amperometric hydrogen peroxide sensors, based on ferrous and copper hexacyanoferrates. Sens Actuators B 56:93-97
    • (1999) Sens Actuators B , vol.56 , pp. 93-97
    • Garjonyte, R.1    Malinauskas, A.2
  • 4
    • 0037214736 scopus 로고    scopus 로고
    • Application of colloidal gold in protein immobilization, electron transfer, and biosensing
    • Liu SQ, Leech D, Ju HX (2003) Application of colloidal gold in protein immobilization, electron transfer, and biosensing. Anal Lett 36:1-17
    • (2003) Anal Lett , vol.36 , pp. 1-17
    • Liu, S.Q.1    Leech, D.2    Ju, H.X.3
  • 6
    • 9944236781 scopus 로고    scopus 로고
    • A comparison of different strategies for the construction of amperometric enzyme biosensors using gold nanoparticle-modified electrodes
    • Mena ML, Yáñez-Sedeño P, Pingarrón JM (2005) A comparison of different strategies for the construction of amperometric enzyme biosensors using gold nanoparticle-modified electrodes. Anal Biochem 336:20-27
    • (2005) Anal Biochem , vol.336 , pp. 20-27
    • Mena, M.L.1    Yáñez-Sedeño, P.2    Pingarrón, J.M.3
  • 7
    • 11844272066 scopus 로고    scopus 로고
    • Development of a tyrosinase biosensor based on gold nanoparticles- modified glassy carbon electrodes: Application to the measurement of a bioelectrochemical polyphenols index in wines
    • Sanz VC, Mena M, González-Cortés A, Yáñez- Sedeño P, Pingarrón JM (2005) Development of a tyrosinase biosensor based on gold nanoparticles-modified glassy carbon electrodes: application to the measurement of a bioelectrochemical polyphenols index in wines. Anal Chim Acta 528:1-8
    • (2005) Anal Chim Acta , vol.528 , pp. 1-8
    • Sanz, V.C.1    Mena, M.2    González-Cortés, A.3    Yáñez- Sedeño, P.4    Pingarrón, J.M.5
  • 8
    • 0032507285 scopus 로고    scopus 로고
    • One-pot colorimetric differentiation of polynucleotides with single base imperfections using gold nanoparticle probes
    • Storhoff JJ, Elghanian R, Music RC, Markin CA, Lestinger RL (1998) One-pot colorimetric differentiation of polynucleotides with single base imperfections using gold nanoparticle probes. J Am Chem Soc 120:1959-1964
    • (1998) J Am Chem Soc , vol.120 , pp. 1959-1964
    • Storhoff, J.J.1    Elghanian, R.2    Music, R.C.3    Markin, C.A.4    Lestinger, R.L.5
  • 9
    • 7544221626 scopus 로고    scopus 로고
    • A novel immunosensor based on immobilization of hepatitis B surface antibody on platinum electrode modified colloidal gold and polyvinyl butyral as matrices via electrochemical impedance spectroscopy
    • Tang DP, Yuan R, Chai YQ, Dai JY, Zhong X, Liu Y (2004) A novel immunosensor based on immobilization of hepatitis B surface antibody on platinum electrode modified colloidal gold and polyvinyl butyral as matrices via electrochemical impedance spectroscopy. Bioelectrochem 65:15-22
    • (2004) Bioelectrochem , vol.65 , pp. 15-22
    • Tang, D.P.1    Yuan, R.2    Chai, Y.Q.3    Dai, J.Y.4    Zhong, X.5    Liu, Y.6
  • 10
    • 1342306779 scopus 로고    scopus 로고
    • A novel method to construct a third-generation biosensor: Self-assembling gold nanoparticles on thiol-functionalized poly(styrene-co-acrylic acid) nanospheres
    • Xu SY, Han XZ (2004) A novel method to construct a third-generation biosensor: self-assembling gold nanoparticles on thiol-functionalized poly(styrene-co-acrylic acid) nanospheres. Biosens Bioelectron 19:1117-1120
    • (2004) Biosens Bioelectron , vol.19 , pp. 1117-1120
    • Xu, S.Y.1    Han, X.Z.2
  • 11
    • 23644454224 scopus 로고    scopus 로고
    • An amperometric immunosensor based on immobilization of hepatitis B surface antibody on gold electrode modified gold nanoparticles and horseradish peroxidase
    • Zhuo Y, Yuan R, Chai YQ (2005) An amperometric immunosensor based on immobilization of hepatitis B surface antibody on gold electrode modified gold nanoparticles and horseradish peroxidase. Anal Chim Acta 548:205-210
    • (2005) Anal Chim Acta , vol.548 , pp. 205-210
    • Zhuo, Y.1    Yuan, R.2    Chai, Y.Q.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.