메뉴 건너뛰기




Volumn 6, Issue 6, 2006, Pages 1638-1643

Calibration transfer among sensor arrays designed for monitoring volatile organic compounds in indoor air quality

Author keywords

Calibration; Gas detectors; Multisensor systems; Statistics

Indexed keywords

CALIBRATION MODELS; SENSOR ARRAYS; TIN OXIDE SENSORS;

EID: 33845622886     PISSN: 1530437X     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSEN.2006.884558     Document Type: Article
Times cited : (20)

References (13)
  • 1
    • 33645999078 scopus 로고    scopus 로고
    • Metal oxide sensor arrays for the detection, differentiation, and quantification of volatile organic compounds at sub-parts-per-million concentration levels
    • May
    • E. J. Wolfrum, R. M. Meglen, D. Peterson, and J. Sluiter, "Metal oxide sensor arrays for the detection, differentiation, and quantification of volatile organic compounds at sub-parts-per-million concentration levels," Sens. Actuators B, Chem., vol. 115, no. 1, pp. 322-329, May 2005.
    • (2005) Sens. Actuators B, Chem. , vol.115 , Issue.1 , pp. 322-329
    • Wolfrum, E.J.1    Meglen, R.M.2    Peterson, D.3    Sluiter, J.4
  • 2
    • 0034230189 scopus 로고    scopus 로고
    • Cross-reactive chemical sensor arrays
    • K. J. Albert et al., "Cross-reactive chemical sensor arrays," Chem. Rev., vol. 100, no. 7, pp. 2595-2626, 2000.
    • (2000) Chem. Rev. , vol.100 , Issue.7 , pp. 2595-2626
    • Albert, K.J.1
  • 3
    • 0034912394 scopus 로고    scopus 로고
    • Organic compounds in indoor air - Their relevance for perceived indoor air quality
    • P. Wolkoff and G. D. Nielsen, "Organic compounds in indoor air - Their relevance for perceived indoor air quality," Atmos. Environ., vol. 35, no. 26, pp. 4407-4417, 2001.
    • (2001) Atmos. Environ. , vol.35 , Issue.26 , pp. 4407-4417
    • Wolkoff, P.1    Nielsen, G.D.2
  • 4
    • 33749430413 scopus 로고    scopus 로고
    • [Online]
    • Air Quality Guidelines. World Health Organization. [Online]. Available: http://www.who.int/indoorair/en/
    • Air Quality Guidelines
  • 5
    • 0003427027 scopus 로고    scopus 로고
    • Atlanta, GA: [Online]
    • Ventilation for Acceptable Indoor Air Quality, 1999, Atlanta, GA: Amer. Soc. Heating, Refrigeration and Air-Conditioning Engineers. [Online]. Available: http://www.ashrae.org/
    • (1999) Ventilation for Acceptable Indoor Air Quality
  • 7
    • 45949123735 scopus 로고
    • Chemometrics and intelligent laboratory systems
    • Aug.
    • S. Wold, K. Ebensen, and P. Geladi, "Chemometrics and intelligent laboratory systems," Principal Component Analysis, vol. 2, no. 1-3, pp. 37-52, Aug. 1987.
    • (1987) Principal Component Analysis , vol.2 , Issue.1-3 , pp. 37-52
    • Wold, S.1    Ebensen, K.2    Geladi, P.3
  • 10
    • 15444353689 scopus 로고
    • An introduction to multivariate calibration
    • Apr.
    • B. R. Kowalski, "An introduction to multivariate calibration," Anal. Chem., vol. 59, no. 7, pp. 1007-1014A, Apr. 1987.
    • (1987) Anal. Chem. , vol.59 , Issue.7
    • Kowalski, B.R.1
  • 12
    • 0000920105 scopus 로고
    • Multivariate instrument standardization
    • Dec.
    • Y. Wang, D. J. Veltkamp, and B. R. Kowalski, "Multivariate instrument standardization," Anal. Chem., vol. 63, no. 23, pp. 2750-2756, Dec. 1991.
    • (1991) Anal. Chem. , vol.63 , Issue.23 , pp. 2750-2756
    • Wang, Y.1    Veltkamp, D.J.2    Kowalski, B.R.3
  • 13
    • 0035499851 scopus 로고    scopus 로고
    • Array-to-array transfer of an artificial nose classifier
    • Nov.
    • S. E. Stitzel, L. J. Cowen, J. A. Albert, and D. R. Walt, "Array-to-array transfer of an artificial nose classifier," Anal. Chem., vol. 73, no. 21, pp. 5266-5271, Nov. 2001.
    • (2001) Anal. Chem. , vol.73 , Issue.21 , pp. 5266-5271
    • Stitzel, S.E.1    Cowen, L.J.2    Albert, J.A.3    Walt, D.R.4