메뉴 건너뛰기




Volumn 2006, Issue , 2006, Pages 649-654

Navigated imaging for neurosurgery

Author keywords

3 d reconstruction; Navigated imaging; Neurosurgery; Registration free; Tomosynthesis

Indexed keywords

IMAGE RECONSTRUCTION; NEUROSURGERY; PROJECTION SYSTEMS; THREE DIMENSIONAL COMPUTER GRAPHICS; X RAY APPARATUS;

EID: 33845589425     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BIOROB.2006.1639163     Document Type: Conference Paper
Times cited : (1)

References (14)
  • 1
    • 0036371298 scopus 로고    scopus 로고
    • Examining the accuracy of mechanical stiffness of the C-arm in navigation procedures
    • Schkommodau E., Soltau J., de la Fuente M., Radermacher K. (2002): Examining the accuracy of mechanical stiffness of the C-arm in navigation procedures, J. Biomed Tech. 2002; 47 Suppl. 1 Pt. 1:41-43.
    • (2002) J. Biomed Tech. 2002 , vol.47 , Issue.1 SUPPL. PART , pp. 41-43
    • Schkommodau, E.1    Soltau, J.2    De La Fuente, M.3    Radermacher, K.4
  • 2
    • 0041904847 scopus 로고    scopus 로고
    • 3D-Bildgebung mit einem mobilen isozentrischen C-Bogen
    • Euler E. et al. (2000): 3D-Bildgebung mit einem mobilen isozentrischen C-Bogen, electromedica 68 Heft 2, pp. 122-126.
    • (2000) Electromedica , vol.68 , Issue.2 , pp. 122-126
    • Euler, E.1
  • 3
    • 0037543297 scopus 로고    scopus 로고
    • Erste klinische erfahrungen mit dem SIREMOBIL Iso-C 3d
    • Euler E. et al. (2002): Erste klinische Erfahrungen mit dem SIREMOBIL Iso-C 3d, electromedica 70 Heft 1, pp. 64-67.
    • (2002) Electromedica , vol.70 , Issue.1 , pp. 64-67
    • Euler, E.1
  • 4
    • 9144248354 scopus 로고    scopus 로고
    • Markerlose Navigation mit der intra-operativen Bildgebungsmodalität SIREMOBIL Iso-C 3d
    • Ritter D. et al. (2002): Markerlose Navigation mit der intra-operativen Bildgebungsmodalität SIREMOBIL Iso-C 3d, electromedica 70 Heft 1, pp. 47-52
    • (2002) Electromedica , vol.70 , Issue.1 , pp. 47-52
    • Ritter, D.1
  • 7
    • 33845588308 scopus 로고    scopus 로고
    • Intraoperative Computerized Tomography in image-guided surgery of spinal fractures
    • Haberland N. et al. (2002): Intraoperative Computerized Tomography in image-guided surgery of spinal fractures, Eur. J. Trauma, E-Suppl., 1/2002, pp. S83-S90
    • (2002) Eur. J. Trauma, E-suppl. , vol.1 , Issue.2002
    • Haberland, N.1
  • 9
    • 0001169360 scopus 로고
    • Über die bestimmung von funktionen durch ihre integralwerte längs gewisser mannigfaltigkeiten
    • Radon J (1917): Über die Bestimmung von Funktionen durch ihre Integralwerte längs gewisser Mannigfaltigkeiten, Ber. Verbhandl. Sachs. Akad. Wiss. Leipzig, Math.-Phys. Kl. 69, pp. 262-277
    • (1917) Ber. Verbhandl. Sachs. Akad. Wiss. Leipzig, Math.-phys. Kl. , vol.69 , pp. 262-277
    • Radon, J.1
  • 10
    • 0141928682 scopus 로고    scopus 로고
    • Digital x-ray tomosynthesis: Current state of the art and clinical potential
    • Dobbins J.T., Godfrey D.J. (2003): Digital x-ray tomosynthesis: current state of the art and clinical potential, Phys. Med. Biol. 48, R65-R106
    • (2003) Phys. Med. Biol. , vol.48
    • Dobbins, J.T.1    Godfrey, D.J.2
  • 11
    • 84907127152 scopus 로고
    • Eine neue methode zur differenzierung in der röntgenographie (planigraphie)
    • Ziedses des Plantes B.G. (1932): Eine neue Methode zur Differenzierung in der Röntgenographie (Planigraphie), Acta Radiol., 13, pp. 182-192
    • (1932) Acta Radiol. , vol.13 , pp. 182-192
    • Ziedses Des Plantes, B.G.1
  • 12
    • 0141976515 scopus 로고
    • Two direct methods for reconstructing pictures from their projections: A comparative study
    • Herman G.T. (1972): Two direct methods for reconstructing pictures from their projections: a comparative study, Comput. Graph. Image Process., 1, pp. 123-144
    • (1972) Comput. Graph. Image Process. , vol.1 , pp. 123-144
    • Herman, G.T.1
  • 13
    • 33845595228 scopus 로고    scopus 로고
    • Navigated imaging for angiography - Concept and calibration
    • Aachen, Germany, 13.-15. Sept. 2004
    • Hein A., Kirschstein U. (2004): Navigated Imaging for Angiography - Concept and Calibration. IEEE Conference on Mechatronics and Robotics 2004, Aachen, Germany, 13.-15. Sept. 2004, pp. 1409-1414.
    • (2004) IEEE Conference on Mechatronics and Robotics 2004 , pp. 1409-1414
    • Hein, A.1    Kirschstein, U.2
  • 14
    • 33845582870 scopus 로고    scopus 로고
    • Measurement of cardiovascular structures in angiographic images with navigated imaging
    • Munich, Germany, October 8-9
    • Kirschstein U., C. Lenze, K. Kronberg, A. Hein (2004) Measurement of cardiovascular structures in angiographic images with navigated imaging, CURAC 2004, Munich, Germany, October 8-9.
    • (2004) CURAC 2004
    • Kirschstein, U.1    Lenze, C.2    Kronberg, K.3    Hein, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.