Volumn 2006, Issue , 2006, Pages 434-438

Gravity-assisted air mixing in data centers and how it affects the Rack cooling effectiveness

Author keywords

Central office; CFD; Gravity; High density; Index; RCI; Telecom; Thermal

Indexed keywords

COMPUTATIONAL FLUID DYNAMICS; COMPUTER SIMULATION; FORCED CONVECTION; GRAVITATION; HEAT LOSSES; MATHEMATICAL MODELS;

EID: 33845572346     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ITHERM.2006.1645375     Document Type: Conference Paper
Times cited : (22)

References (6)
  • 1
    • 25844468162 scopus 로고    scopus 로고
    • ASHRAE Special Publication, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA
    • ASHRAE Special Publication, Datacom Equipment Power Trends and Cooling Applications, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA, 2005.
    • (2005) Datacom Equipment Power Trends and Cooling Applications
  • 2
    • 29144450886 scopus 로고    scopus 로고
    • Rack cooling effectiveness in data centers and telecom central offices: The Rack Cooling Index (RCI)
    • Part 2, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA
    • M. K. Herrlin, "Rack Cooling Effectiveness in Data Centers and Telecom Central Offices: The Rack Cooling Index (RCI)," ASHRAE Transactions, Vol. 111, Part 2, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA, 2005.
    • (2005) ASHRAE Transactions , vol.111
    • Herrlin, M.K.1
  • 3
    • 0346280209 scopus 로고    scopus 로고
    • Computational fluid dynamics modelling of high compute density data centers to assure system inlet air specification
    • C. Patel et al., "Computational Fluid Dynamics Modelling of High Compute Density Data Centers to Assure System Inlet Air Specification," Proceedings of International Electronic Packaging Technical Conference and Exhibition, pp 821-829, 2001.
    • (2001) Proceedings of International Electronic Packaging Technical Conference and Exhibition , pp. 821-829
    • Patel, C.1
  • 4
    • 4344572635 scopus 로고    scopus 로고
    • ASHRAE Special Publication, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA
    • ASHRAE Special Publication, Thermal Guidelines for Data Processing Environments, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA, 2004.
    • (2004) Thermal Guidelines for Data Processing Environments
  • 5
    • 33845587962 scopus 로고    scopus 로고
    • Telcordia Generic Requirements, December 2001, Telcordia Technologies Inc., Piscataway, NJ
    • Telcordia Generic Requirements, NEBS GR-3028-CORE Thermal Management in Telecommunications Central Offices, Issue 1, December 2001, Telcordia Technologies Inc., Piscataway, NJ, 2001.
    • (2001) NEBS GR-3028-CORE Thermal Management in Telecommunications Central Offices , Issue.1
  • 6
    • 33845568583 scopus 로고    scopus 로고
    • Telcordia Generic Requirements, April, Telcordia Technologies Inc., Piscataway, NJ, 2002
    • Telcordia Generic Requirements, NEBS GR-63-CORE, NEBS Requirements: Physical Protection, Issue 2, April 2002, Telcordia Technologies Inc., Piscataway, NJ, 2002.
    • (2002) NEBS GR-63-CORE, NEBS Requirements: Physical Protection , Issue.2