메뉴 건너뛰기




Volumn 2006, Issue , 2006, Pages

Vessels as 4D curves: Global minimal 4D paths to extract 3D tubular surfaces

Author keywords

[No Author keywords available]

Indexed keywords

ACTIVE SURFACE TECHNIQUES; FAST COMPUTATION; GLOBAL MINIMIZING TRAJECTORIES; TUBULAR SURFACE;

EID: 33845527147     PISSN: 10636919     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CVPRW.2006.210     Document Type: Conference Paper
Times cited : (19)

References (33)
  • 1
    • 28144437204 scopus 로고
    • A fast level set method for propagating interfaces
    • 3
    • D. Adalsteinsson and J. Sethian. A fast level set method for propagating interfaces. Journal of Computational Physics, 118(2):269-277, 1995. 3
    • (1995) Journal of Computational Physics , vol.118 , Issue.2 , pp. 269-277
    • Adalsteinsson, D.1    Sethian, J.2
  • 3
    • 18144382323 scopus 로고    scopus 로고
    • Flux driven automatic centerline extraction
    • 1
    • S. Bouix, K. Siddiqi, and A. Tannenbaum. Flux driven automatic centerline extraction. Medical Image Analysis, 9(3):209-221, 2005. 1
    • (2005) Medical Image Analysis , vol.9 , Issue.3 , pp. 209-221
    • Bouix, S.1    Siddiqi, K.2    Tannenbaum, A.3
  • 5
    • 10044257523 scopus 로고    scopus 로고
    • Vascular segmentation of phase contrast magnetic resonance angiograms based on statistical mixture modeling and local phase coherence
    • 1
    • A. Chung, A. Noble, and P. Summers. Vascular segmentation of phase contrast magnetic resonance angiograms based on statistical mixture modeling and local phase coherence. IEEE Transactions on Medical Imaging, 23(12):1490-1507, 2004. 1
    • (2004) IEEE Transactions on Medical Imaging , vol.23 , Issue.12 , pp. 1490-1507
    • Chung, A.1    Noble, A.2    Summers, P.3
  • 6
    • 0028903345 scopus 로고
    • MRI segmentation: Methods and applications
    • 1
    • L. Clarke et al. MRI segmentation: Methods and applications. Magnetic Resonance Imaging, 13(3):343-368, 1995. 1
    • (1995) Magnetic Resonance Imaging , vol.13 , Issue.3 , pp. 343-368
    • Clarke, L.1
  • 7
    • 0035328930 scopus 로고    scopus 로고
    • Multiple contour finding and perceptual grouping using minimal paths
    • 1, 3
    • L. Cohen. Multiple contour finding and perceptual grouping using minimal paths. Journal of Mathematical Imaging and Vision, 14(3):225-236, 2001. 1, 3
    • (2001) Journal of Mathematical Imaging and Vision , vol.14 , Issue.3 , pp. 225-236
    • Cohen, L.1
  • 8
    • 0031213363 scopus 로고    scopus 로고
    • Global minimum for active contour models: A minimal path approach
    • 1, 3, 4, 7
    • L. Cohen and R. Kimmel. Global minimum for active contour models: A minimal path approach. International Journal of Computer Vision, 24(1):57-78, 1997. 1, 3, 4, 7
    • (1997) International Journal of Computer Vision , vol.24 , Issue.1 , pp. 57-78
    • Cohen, L.1    Kimmel, R.2
  • 9
    • 0035779633 scopus 로고    scopus 로고
    • Fast extraction of minimal paths in 3D images and applications to virtual endoscopy
    • 1, 2
    • T. Deschamps and L. Cohen. Fast extraction of minimal paths in 3D images and applications to virtual endoscopy. Medical Image Analysis, 5(4):281-299, 2001. 1, 2
    • (2001) Medical Image Analysis , vol.5 , Issue.4 , pp. 281-299
    • Deschamps, T.1    Cohen, L.2
  • 11
    • 0000454238 scopus 로고
    • An optimal control formulation and related numerical methods for a problem in shape reconstruction
    • 3
    • P. Dupuis and J. Oliensis. An optimal control formulation and related numerical methods for a problem in shape reconstruction. Annals of Applied Probability, 4(2):287-346, 1994. 3
    • (1994) Annals of Applied Probability , vol.4 , Issue.2 , pp. 287-346
    • Dupuis, P.1    Oliensis, J.2
  • 15
    • 28644434715 scopus 로고    scopus 로고
    • A review of vessel extraction techniques and algorithms
    • 1
    • C. Kirbas and F. Quek. A review of vessel extraction techniques and algorithms. ACM Computing Surveys (CSUR), 36(2):81-121, 2004. 1
    • (2004) ACM Computing Surveys (CSUR) , vol.36 , Issue.2 , pp. 81-121
    • Kirbas, C.1    Quek, F.2
  • 17
    • 31744449468 scopus 로고    scopus 로고
    • Level set based cerebral vasculature segmentation and diameter quantification in CT angiography
    • 1
    • R. Manniesing et al. Level set based cerebral vasculature segmentation and diameter quantification in CT angiography. Medical Image Analysis, 10(2):200-214, 2006. 1
    • (2006) Medical Image Analysis , vol.10 , Issue.2 , pp. 200-214
    • Manniesing, R.1
  • 18
    • 0030153642 scopus 로고    scopus 로고
    • Deformable models in medical image analysis: A survey
    • 1
    • T. McInerney and D. Terzopoulos. Deformable models in medical image analysis: A survey. Medical. Imaging Analysis, 1(2):91-108, 1996. 1
    • (1996) Medical. Imaging Analysis , vol.1 , Issue.2 , pp. 91-108
    • McInerney, T.1    Terzopoulos, D.2
  • 19
    • 20344397426 scopus 로고    scopus 로고
    • Vessel segmentation using a shape driven flow. in
    • 1
    • D. Nain, A. Yezzi, and G. Turk. Vessel segmentation using a shape driven flow. In MICCAI04, volume LNCS 3216, pages 51-59, 2004. 1
    • (2004) MICCAI04 , vol.LNCS 3216 , pp. 51-59
    • Nain, D.1    Yezzi, A.2    Turk, G.3
  • 20
    • 11244346584 scopus 로고    scopus 로고
    • Minimum cost path algorithm for coronary artery central axis tracking in CT images
    • 1
    • S. Olabarriaga, M. Breeuwer, and W. Niessen. Minimum cost path algorithm for coronary artery central axis tracking in CT images. In MICCAI, volume 2879, pages 687-694, 2003. 1
    • (2003) MICCAI , vol.2879 , pp. 687-694
    • Olabarriaga, S.1    Breeuwer, M.2    Niessen, W.3
  • 22
    • 0026880997 scopus 로고
    • A viscosity solutions approach to shape-from-shading
    • 3
    • E. Rouy and A. Tourin. A viscosity solutions approach to shape-from-shading. SIAM Journal of Numerical. Analysis, 29(3):867-884, 1992. 3
    • (1992) SIAM Journal of Numerical. Analysis , vol.29 , Issue.3 , pp. 867-884
    • Rouy, E.1    Tourin, A.2
  • 23
    • 0030988627 scopus 로고    scopus 로고
    • Automatic extraction and measurement of leukocyte motion in microvessels using spatiotemporal image analysis
    • 1
    • Y. Sato, J. Chen, et al. Automatic extraction and measurement of leukocyte motion in microvessels using spatiotemporal image analysis. IEEE Transactions on Biomedical Engineering, 44(4):225-236, 1997. 1
    • (1997) IEEE Transactions on Biomedical Engineering , vol.44 , Issue.4 , pp. 225-236
    • Sato, Y.1    Chen, J.2
  • 24
    • 0029966538 scopus 로고    scopus 로고
    • A fast marching level set method for monotonically advancing fronts
    • 3
    • J. Sethian. A fast marching level set method for monotonically advancing fronts. Proceedings of the National Academy of Science of USA, 93(4):1591-1595, 1996. 3
    • (1996) Proceedings of the National Academy of Science of USA , vol.93 , Issue.4 , pp. 1591-1595
    • Sethian, J.1
  • 25
    • 0032631799 scopus 로고    scopus 로고
    • Fast marching methods
    • 1, 4, 5
    • J. Sethian. Fast marching methods. SIAM Review, 41(2):199-235, 1999. 1, 4, 5
    • (1999) SIAM Review , vol.41 , Issue.2 , pp. 199-235
    • Sethian, J.1
  • 26
    • 0031060806 scopus 로고    scopus 로고
    • Adaptive approach to accurate analysis of small-diameter vessels in cineangiograms
    • 1
    • M. Sonka, G. Reddy, M. Winniford, and S. Collins. Adaptive approach to accurate analysis of small-diameter vessels in cineangiograms. IEEE Transactions on Medical. Imaging, 16(1):87-95, 1997. 1
    • (1997) IEEE Transactions on Medical. Imaging , vol.16 , Issue.1 , pp. 87-95
    • Sonka, M.1    Reddy, G.2    Winniford, M.3    Collins, S.4
  • 28
    • 0029327157 scopus 로고
    • Assessment of diffuse coronary artery disease by quantitative analysis of coronary morphology based upon 3D reconstruction from biplane angiograms
    • 1
    • A. Wahle, E. Wellnhofer, I. Mugaragu, H. Saner, H. Oswald, and E. Fleck. Assessment of diffuse coronary artery disease by quantitative analysis of coronary morphology based upon 3D reconstruction from biplane angiograms. IEEE Transactions on Medical Imaging, 14(2):230-241, 1995. 1
    • (1995) IEEE Transactions on Medical Imaging , vol.14 , Issue.2 , pp. 230-241
    • Wahle, A.1    Wellnhofer, E.2    Mugaragu, I.3    Saner, H.4    Oswald, H.5    Fleck, E.6
  • 32
    • 0034195221 scopus 로고    scopus 로고
    • Gray-scale skeletonization of small vessels in magnetic resonance angiography
    • 1
    • P. Yim, P. Choyke, and R. Summers. Gray-scale skeletonization of small vessels in magnetic resonance angiography. IEEE Transactions on Medical. Imaging, 19(6):568-576, 2000. 1
    • (2000) IEEE Transactions on Medical. Imaging , vol.19 , Issue.6 , pp. 568-576
    • Yim, P.1    Choyke, P.2    Summers, R.3
  • 33
    • 0035397820 scopus 로고    scopus 로고
    • Segmentation of vessel-like patterns using mathematical morphology and curvature evaluation
    • 1
    • F. Zana and J. Klein. Segmentation of vessel-like patterns using mathematical morphology and curvature evaluation. IEEE Transactions on Image Processing, 10(7):1010-1019, 2001. 1
    • (2001) IEEE Transactions on Image Processing , vol.10 , Issue.7 , pp. 1010-1019
    • Zana, F.1    Klein, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.