메뉴 건너뛰기




Volumn 20, Issue 6, 2006, Pages 268-272

Pulse oximetry revisited: "But his O2 sat was normal!"

Author keywords

[No Author keywords available]

Indexed keywords

OXYGEN;

EID: 33845501866     PISSN: 08876274     EISSN: 15389782     Source Type: Journal    
DOI: 10.1097/00002800-200611000-00004     Document Type: Review
Times cited : (9)

References (28)
  • 3
    • 33646124280 scopus 로고    scopus 로고
    • Oxygen saturation monitoring by pulse oximetry
    • Wiegand DJ, Carlson KK, eds. St. Louis, Mo: Elsevier Saunders
    • Schutz SL. Oxygen saturation monitoring by pulse oximetry. In: Wiegand DJ, Carlson KK, eds. AACN Procedure Manual for Critical Care. 5th ed. St. Louis, Mo: Elsevier Saunders; 2005:101-107.
    • (2005) AACN Procedure Manual for Critical Care. 5th Ed. , pp. 101-107
    • Schutz, S.L.1
  • 4
    • 19944431797 scopus 로고    scopus 로고
    • Outpatient care compared with hospitalization for community-acquired pneumonia: A randomized trial in low-risk patients
    • Carratala J, Fernandez-Sabe N, Ortega L, et al. Outpatient care compared with hospitalization for community-acquired pneumonia: a randomized trial in low-risk patients. Ann Intern Med. 2005;142:165-172.
    • (2005) Ann Intern Med , vol.142 , pp. 165-172
    • Carratala, J.1    Fernandez-Sabe, N.2    Ortega, L.3
  • 5
    • 0031012761 scopus 로고    scopus 로고
    • A prediction rule to identify low-risk patients with community-acquired pneumonia
    • Fine MJ, Auble TE, Yealy DM, et al. A prediction rule to identify low-risk patients with community-acquired pneumonia. N Engl J Med. 1997;336:243-250.
    • (1997) N Engl J Med , vol.336 , pp. 243-250
    • Fine, M.J.1    Auble, T.E.2    Yealy, D.M.3
  • 6
    • 12144253593 scopus 로고    scopus 로고
    • New generation pulse oximetry in the care of critically ill patients
    • Guiliano KK, Higgins TL. New generation pulse oximetry in the care of critically ill patients. Am J Crit Care. 2005;14(1):26-39.
    • (2005) Am J Crit Care , vol.14 , Issue.1 , pp. 26-39
    • Guiliano, K.K.1    Higgins, T.L.2
  • 7
    • 0037304094 scopus 로고    scopus 로고
    • Pulse oximetry for perioperative monitoring: Systematic review of randomized, controlled trials
    • Pedersen T, Møller AM, Pedersen BD. Pulse oximetry for perioperative monitoring: systematic review of randomized, controlled trials. Anesth Analg. 2003;96:426-431.
    • (2003) Anesth Analg , vol.96 , pp. 426-431
    • Pedersen, T.1    Møller, A.M.2    Pedersen, B.D.3
  • 8
    • 14044278799 scopus 로고    scopus 로고
    • Pulse oximetry as a potential screening tool for lower extremity arterial disease in asymptomatic patients with diabetes mellitus
    • Parameswaran G, Brand K, Dolan J. Pulse oximetry as a potential screening tool for lower extremity arterial disease in asymptomatic patients with diabetes mellitus. Arch Intern Med. 2005;165:442-446.
    • (2005) Arch Intern Med , vol.165 , pp. 442-446
    • Parameswaran, G.1    Brand, K.2    Dolan, J.3
  • 9
    • 33645279601 scopus 로고    scopus 로고
    • Knowledge of pulse oximetry among critical care nurses
    • Giuliano KK, Liu L. Knowledge of pulse oximetry among critical care nurses. Dimens Crit Care Nurs. 2006;25(1):1-6.
    • (2006) Dimens Crit Care Nurs , vol.25 , Issue.1 , pp. 1-6
    • Giuliano, K.K.1    Liu, L.2
  • 10
    • 0036834614 scopus 로고    scopus 로고
    • An education project to improve knowledge related to pulse oximetry
    • from the Nursing Practice Research Council, University of California, Los Angeles, Medical Center, Los Angeles, California
    • Attin M, Cardin S, Dee V, et al, from the Nursing Practice Research Council, University of California, Los Angeles, Medical Center, Los Angeles, California. An education project to improve knowledge related to pulse oximetry. Am J Crit Care. 2002;11:529-534.
    • (2002) Am J Crit Care , vol.11 , pp. 529-534
    • Attin, M.1    Cardin, S.2    Dee, V.3
  • 11
    • 15344348833 scopus 로고    scopus 로고
    • The pulse in reflectance pulse oximetry: Modeling and experimental studies
    • Reuss JL, Siker D. The pulse in reflectance pulse oximetry: modeling and experimental studies. J Clin Monit Comput. 2004;18:289-299.
    • (2004) J Clin Monit Comput , vol.18 , pp. 289-299
    • Reuss, J.L.1    Siker, D.2
  • 12
    • 11244319685 scopus 로고    scopus 로고
    • Pulse oximetry in supportive and palliative care
    • Vora VA, Ahmedzai SH. Pulse oximetry in supportive and palliative care. Support Care Cancer. 2004;12(11):758-761.
    • (2004) Support Care Cancer , vol.12 , Issue.11 , pp. 758-761
    • Vora, V.A.1    Ahmedzai, S.H.2
  • 13
    • 29244441648 scopus 로고    scopus 로고
    • Pulse oximetry in the oesophagus
    • Kyriacou PA. Pulse oximetry in the oesophagus. Physiol Meas. 2006;27(1):R1-35.
    • (2006) Physiol Meas , vol.27 , Issue.1
    • Kyriacou, P.A.1
  • 14
    • 0742303088 scopus 로고    scopus 로고
    • Design of filter to reject motion artifact of pulse oximetry
    • Lee J, Jung W, Kang I, Kim Y, Lee G. Design of filter to reject motion artifact of pulse oximetry. Comput Stand Interfaces. 2004;26(3):241-249.
    • (2004) Comput Stand Interfaces , vol.26 , Issue.3 , pp. 241-249
    • Lee, J.1    Jung, W.2    Kang, I.3    Kim, Y.4    Lee, G.5
  • 15
    • 11144251672 scopus 로고    scopus 로고
    • Pulse oximetry
    • Jubran A. Pulse oximetry. Intensive Care Med. 2004;30(11):2017-2020.
    • (2004) Intensive Care Med , vol.30 , Issue.11 , pp. 2017-2020
    • Jubran, A.1
  • 18
    • 0028300877 scopus 로고
    • Crying wolf: False alarms in a pediatric intensive care unit
    • Lawless S. Crying wolf: false alarms in a pediatric intensive care unit. Crit Care Med. 1994;22(6):981-985.
    • (1994) Crit Care Med , vol.22 , Issue.6 , pp. 981-985
    • Lawless, S.1
  • 19
    • 0029180865 scopus 로고
    • Are there too many alarms in the intensive care unit? An overview of the problems
    • Meredith C, Edworthy J. Are there too many alarms in the intensive care unit? An overview of the problems. J Adv Nurs. 1995;21(1):15-20.
    • (1995) J Adv Nurs , vol.21 , Issue.1 , pp. 15-20
    • Meredith, C.1    Edworthy, J.2
  • 20
    • 1542286534 scopus 로고    scopus 로고
    • Continuous pulse oximeter monitoring for inapparent hypoxemia after long bone fractures
    • Wong MWN, Tsui HF, Yung SH, Chan KM, Cheng JCY. Continuous pulse oximeter monitoring for inapparent hypoxemia after long bone fractures. J Trauma. 2004;56(2):356-362.
    • (2004) J Trauma , vol.56 , Issue.2 , pp. 356-362
    • Wong, M.W.N.1    Tsui, H.F.2    Yung, S.H.3    Chan, K.M.4    Cheng, J.C.Y.5
  • 21
    • 33644553810 scopus 로고    scopus 로고
    • The impact of continuous pulse oximetry monitoring on intensive care unit admissions from a postsurgical care floor
    • Ochrock EA, Russell MW, Hanson WC, et al. The impact of continuous pulse oximetry monitoring on intensive care unit admissions from a postsurgical care floor. Anesth Analg. 2006;102:868-875.
    • (2006) Anesth Analg , vol.102 , pp. 868-875
    • Ochrock, E.A.1    Russell, M.W.2    Hanson, W.C.3
  • 22
    • 33845475529 scopus 로고    scopus 로고
    • Arterial blood gas analysis
    • Kidd PS, Wagner KD, eds. Upper Saddle River, NJ: Prentice Hall
    • Wagner KD. Arterial blood gas analysis. In: Kidd PS, Wagner KD, eds. High Acuity Nursing. 3rd ed. Upper Saddle River, NJ: Prentice Hall; 2001:144-161.
    • (2001) High Acuity Nursing. 3rd Ed. , pp. 144-161
    • Wagner, K.D.1
  • 23
    • 33645009520 scopus 로고
    • Hemoglobin saturation (SaO2) and DO2
    • Ahrens T, Rutherford K, eds. Boston: Jones and Bartlett Publishers
    • Rutherford K. Hemoglobin saturation (SaO2) and DO2. In: Ahrens T, Rutherford K, eds. Essentials of Oxygenation. Boston: Jones and Bartlett Publishers; 1993:43-46.
    • (1993) Essentials of Oxygenation , pp. 43-46
    • Rutherford, K.1
  • 24
    • 33845488611 scopus 로고    scopus 로고
    • Respiratory
    • Mobile, Ala: Kathy White Learning Systems
    • White KM. Respiratory. In: Fast Facts for Adult Critical Care. Mobile, Ala: Kathy White Learning Systems; 2005:3-4.
    • (2005) Fast Facts for Adult Critical Care , pp. 3-4
    • White, K.M.1
  • 25
    • 0036140133 scopus 로고    scopus 로고
    • A characterization of motion affecting pulse oximetry in 350 patients
    • Tobin RM, Pologe JA, Batchelder PB. A characterization of motion affecting pulse oximetry in 350 patients. Anesth Analg. 2002;94(15):554-561.
    • (2002) Anesth Analg , vol.94 , Issue.15 , pp. 554-561
    • Tobin, R.M.1    Pologe, J.A.2    Batchelder, P.B.3
  • 26
    • 8744243235 scopus 로고    scopus 로고
    • Supplemental oxygen impairs detection of hypoventilation by pulse oximetry
    • Fu ES, Downs JB, Schweiger JW, Miguel RV, Smith RA. Supplemental oxygen impairs detection of hypoventilation by pulse oximetry. Chest. 2004;126(5):1552-1558.
    • (2004) Chest , vol.126 , Issue.5 , pp. 1552-1558
    • Fu, E.S.1    Downs, J.B.2    Schweiger, J.W.3    Miguel, R.V.4    Smith, R.A.5
  • 27
    • 14544267165 scopus 로고    scopus 로고
    • Detection of a systolic pressure threshold for reliable readings in pulse oximetry
    • Hinkelbein J, Genzwuerker HV, Fiedler F. Detection of a systolic pressure threshold for reliable readings in pulse oximetry. Resuscitation. 2005;64(3):315-319.
    • (2005) Resuscitation , vol.64 , Issue.3 , pp. 315-319
    • Hinkelbein, J.1    Genzwuerker, H.V.2    Fiedler, F.3
  • 28
    • 0027354824 scopus 로고
    • Toward a theory of technology dependency
    • Sandelowski M. Toward a theory of technology dependency. Nurs Outlook. 1993;41:40.
    • (1993) Nurs Outlook , vol.41 , pp. 40
    • Sandelowski, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.