Pendra goes Dutch; lessons for the CE mark in Europe

Author keywords

Artificial pancreas; Continuous glucose monitoring; Diabetes; Glucose sensor; Impedance spectroscopy; Metabolic control

Indexed keywords

ANALYTICAL ERROR; ARTICLE; ARTIFICIAL PANCREAS; BLOOD GLUCOSE MONITORING; CALIBRATION; CERTIFICATION; CONSENSUS; CORRELATION COEFFICIENT; COST EFFECTIVENESS ANALYSIS; DEVICE; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; EUROPE; GLUCOSE BLOOD LEVEL; HUMAN; IMPEDANCE SPECTROSCOPY; INSULIN DEPENDENT DIABETES MELLITUS; MARKET; METABOLIC REGULATION; NETHERLANDS; NON INVASIVE PROCEDURE; PUBLICATION; RELIABILITY; SAFETY; SELF MONITORING; SENSOR; SPECTROSCOPY; SYSTEM ANALYSIS;

EID: 33845484245     PISSN: 01688227     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0168-8227(06)70006-7     Document Type: Article
Times cited : (6)

References (11)
  • 1
    • 0026764010 scopus 로고
    • Frequency domain impedance measurements of erythrocytes. Constant phase angle impedance characteristics and a phase transition
    • Bao J., and Davis C. Frequency domain impedance measurements of erythrocytes. Constant phase angle impedance characteristics and a phase transition. Biophys J 61 (1992) 1427-1434
    • (1992) Biophys J , vol.61 , pp. 1427-1434
    • Bao, J.1    Davis, C.2
  • 2
    • 0028145927 scopus 로고
    • Dielectric spectroscopy of human blood
    • Beving H., and Eriksson G. Dielectric spectroscopy of human blood. Eur J Surg Suppl 574 (1994) 87-89
    • (1994) Eur J Surg Suppl , vol.574 , pp. 87-89
    • Beving, H.1    Eriksson, G.2
  • 3
    • 0027770048 scopus 로고
    • Electrical impedance and erythrocyte sedimentation rate (ESR) of blood
    • Zhao T., and Lockner D. Electrical impedance and erythrocyte sedimentation rate (ESR) of blood. Biochim Biophys Acta 1153 (1993) 243-248
    • (1993) Biochim Biophys Acta , vol.1153 , pp. 243-248
    • Zhao, T.1    Lockner, D.2
  • 4
    • 4344615386 scopus 로고    scopus 로고
    • Impact of posture and fixation technique on impedance spectroscopy used for continuous and noninvasive glucose monitoring
    • Pfutzner A., Caduff A., Larbig M., Schrepfer T., and Forst T. Impact of posture and fixation technique on impedance spectroscopy used for continuous and noninvasive glucose monitoring. Diabetes Technol Ther 6 (2004) 435-441
    • (2004) Diabetes Technol Ther , vol.6 , pp. 435-441
    • Pfutzner, A.1    Caduff, A.2    Larbig, M.3    Schrepfer, T.4    Forst, T.5
  • 5
    • 0242357278 scopus 로고    scopus 로고
    • First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system
    • Caduff A., Hirt E., Feldman Y., Ali Z., and Heinemann L. First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system. Biosens Bioeiectron 19 (2003) 209-217
    • (2003) Biosens Bioeiectron , vol.19 , pp. 209-217
    • Caduff, A.1    Hirt, E.2    Feldman, Y.3    Ali, Z.4    Heinemann, L.5
  • 6
    • 0142213236 scopus 로고    scopus 로고
    • Wrist-wearable medical devices: technologies and applications
    • Scheffler M., Hirt E., and Caduff A. Wrist-wearable medical devices: technologies and applications. Med Device Technol 14 (2003) 26-30
    • (2003) Med Device Technol , vol.14 , pp. 26-30
    • Scheffler, M.1    Hirt, E.2    Caduff, A.3
  • 7
    • 0041666413 scopus 로고    scopus 로고
    • Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insuiin analogs
    • Guerci B., Floriot M., Bohme P., Durain D., Benichou M., Jellimann S., et al. Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insuiin analogs. Diabetes Care 26 (2003) 582-589
    • (2003) Diabetes Care , vol.26 , pp. 582-589
    • Guerci, B.1    Floriot, M.2    Bohme, P.3    Durain, D.4    Benichou, M.5    Jellimann, S.6
  • 8
    • 0242418182 scopus 로고    scopus 로고
    • A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 2)
    • Varalli M., Marelli G., Maran A., Bistoni S., Luzzana M., Cremonesi P., et al. A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 2). Biosens Bioelectron 18 (2003) 899-905
    • (2003) Biosens Bioelectron , vol.18 , pp. 899-905
    • Varalli, M.1    Marelli, G.2    Maran, A.3    Bistoni, S.4    Luzzana, M.5    Cremonesi, P.6
  • 9
    • 0036481429 scopus 로고    scopus 로고
    • Continuous subcutaneous glucose monitoring in diabetic patients: a multicenter analysis
    • Maran A., Crepaldi C., Tiengo A., Grassi G., Vitali E., Pagano G., et al. Continuous subcutaneous glucose monitoring in diabetic patients: a multicenter analysis. Diabetes Care 25 (2002) 347-352
    • (2002) Diabetes Care , vol.25 , pp. 347-352
    • Maran, A.1    Crepaldi, C.2    Tiengo, A.3    Grassi, G.4    Vitali, E.5    Pagano, G.6
  • 10
    • 33845474133 scopus 로고    scopus 로고
    • Hope or hype: the obsession with medical advances and the high cost of false promises
    • Foreman J. Hope or hype: the obsession with medical advances and the high cost of false promises. New Engl J Med 352 (2005) 1615-1616
    • (2005) New Engl J Med , vol.352 , pp. 1615-1616
    • Foreman, J.1
  • 11
    • 0035021705 scopus 로고    scopus 로고
    • Sensors for glucose monitoring: technical and clinical aspects
    • Koschinsky T., and Heinemann L. Sensors for glucose monitoring: technical and clinical aspects. Diabetes Metab Res Rev 17 (2001) 113-123
    • (2001) Diabetes Metab Res Rev , vol.17 , pp. 113-123
    • Koschinsky, T.1    Heinemann, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.