메뉴 건너뛰기




Volumn 37, Issue 2, 2007, Pages 262-267

An improved matched filter for blood vessel detection of digital retinal images

Author keywords

Digital image; DRIVE; Matched filter; Retina image; Retinopathy; Vessel detection

Indexed keywords

DATABASE SYSTEMS; IMAGE PROCESSING; IMAGE SEGMENTATION; MEDICAL IMAGING; OPTIMIZATION; PARAMETER ESTIMATION;

EID: 33845430530     PISSN: 00104825     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.compbiomed.2006.03.003     Document Type: Article
Times cited : (288)

References (16)
  • 1
    • 0024734454 scopus 로고
    • Detection of blood vessels in retinal images using two dimensional matched filters
    • Chaudhuri S., Chatterjee S., Katz N., Nelson M., and Goldbaum M. Detection of blood vessels in retinal images using two dimensional matched filters. IEEE Trans. Med. Imaging 8 3 (1989) 263-269
    • (1989) IEEE Trans. Med. Imaging , vol.8 , Issue.3 , pp. 263-269
    • Chaudhuri, S.1    Chatterjee, S.2    Katz, N.3    Nelson, M.4    Goldbaum, M.5
  • 2
    • 2342655636 scopus 로고    scopus 로고
    • A. Banumathi, R. Karthika, A. Kumar, Performance analysis of matched filter techniques for automated detection of blood vessels in retinal images, TENCON 2003, Conference on Convergent Technologies for Asia-Pacific Region, vol. 2, October 2003, pp. 543-546.
  • 3
    • 0030394868 scopus 로고    scopus 로고
    • M. Goldbaum, S. Moezzi, A. Taylor, S. Chatterjee, J. Boyd, E. Hunter, R. Jain, Automated diagnosis and image understanding with object extraction, object classification, and inferencing in retinal images, IEEE International Conference on Image Processing, Proceedings, vol. 3, September 1996, pp. 695-698.
  • 4
    • 0347210460 scopus 로고    scopus 로고
    • W. Hart, M. Goldbaum, B. Cote, P. Kube, M. Nelson, Automated measurement of retinal vascular tortuosity, in: Proceedings AMIA Fall Conference, 1997, pp. 459-463.
  • 6
    • 0035397820 scopus 로고    scopus 로고
    • Segmentation of vessel like patterns using mathematical morphology and curvature evaluation
    • Zana F., and Klein J.C. Segmentation of vessel like patterns using mathematical morphology and curvature evaluation. IEEE Trans. Image Process. 10 7 (2001) 1010-1019
    • (2001) IEEE Trans. Image Process. , vol.10 , Issue.7 , pp. 1010-1019
    • Zana, F.1    Klein, J.C.2
  • 8
    • 5644287725 scopus 로고    scopus 로고
    • M. Niemeijer, J. Staal, B. van Ginneken, M. Loog, M.D. Abràmoff, Comparative study of retinal vessel segmentation methods on a new publicly available database, in: Amini, A. Amir, Manduca, Armando (Eds.), Medical Imaging: Physiology, Function, and Structure from Medical Images, Proceedings of the SPIE, vol. 5370, 2004, pp. 648-656.
  • 9
    • 84949481584 scopus 로고    scopus 로고
    • L. Jorge, C. Roberto, J. Herbert, Blood vessels segmentation in retina: preliminary assessment of the mathematical morphology and of the wavelet transform techniques, XIV Brazilian Symposium on Computer Graphics and Image Processing, 2001.
  • 10
    • 33845394763 scopus 로고    scopus 로고
    • O. Chutatape, L. Zheng, S.M. Krishnan, Retinal blood vessel detection and tracking by matched Gaussian and Kalman filter, in: Proceedings 20th Annual Conference IEEE Engineering in Medicine and Biology Society, vol. 20 (6), October 1998, pp. 3144-3149.
  • 11
    • 0033623974 scopus 로고    scopus 로고
    • Locating blood vessels in retinal images by piecewise threshold probing of a matched filter responses
    • Hoover A., Kouzntesova V., and Goldbaum M. Locating blood vessels in retinal images by piecewise threshold probing of a matched filter responses. IEEE Trans. Med. Imaging 19 3 (2000) 203-210
    • (2000) IEEE Trans. Med. Imaging , vol.19 , Issue.3 , pp. 203-210
    • Hoover, A.1    Kouzntesova, V.2    Goldbaum, M.3
  • 12
    • 0036156161 scopus 로고    scopus 로고
    • Detection and measurement of retinal vessels in fundus image using amplitude modified second order Gaussian filter
    • Gang L., Chutatape O., and Krishnan S.M. Detection and measurement of retinal vessels in fundus image using amplitude modified second order Gaussian filter. IEEE Trans. Biomed. Eng. 49 2 (2003) 168-172
    • (2003) IEEE Trans. Biomed. Eng. , vol.49 , Issue.2 , pp. 168-172
    • Gang, L.1    Chutatape, O.2    Krishnan, S.M.3
  • 13
    • 0032588588 scopus 로고    scopus 로고
    • A multimodal registration algorithm of eye fundus images using vessels detection and Hough transform
    • Zana F., and Klein J.C. A multimodal registration algorithm of eye fundus images using vessels detection and Hough transform. IEEE Trans. Med. Imaging 18 5 (1999) 419-428
    • (1999) IEEE Trans. Med. Imaging , vol.18 , Issue.5 , pp. 419-428
    • Zana, F.1    Klein, J.C.2
  • 14
    • 0018306059 scopus 로고
    • A threshold selection method from gray-level histograms
    • Otsu N. A threshold selection method from gray-level histograms. IEEE Trans. Syst. Man Cybernet. 9 (1979) 62-66
    • (1979) IEEE Trans. Syst. Man Cybernet. , vol.9 , pp. 62-66
    • Otsu, N.1
  • 16
    • 0015077742 scopus 로고
    • Computer determination of the constitute structure of biomedical images
    • Kirsch R. Computer determination of the constitute structure of biomedical images. Comput. Biomed. Res. 4 3 (1971) 315-328
    • (1971) Comput. Biomed. Res. , vol.4 , Issue.3 , pp. 315-328
    • Kirsch, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.