메뉴 건너뛰기




Volumn 21, Issue 3, 2007, Pages 1499-1511

Design, development and testing of a four-component milling dynamometer for the measurement of cutting force and torque

Author keywords

Cutting forces; Data acquisition; Dynamometer; Milling; Strain gauge; Torque

Indexed keywords

ACCELEROMETERS; COMMINUTION; DATA ACQUISITION; STRAIN GAGES; TORQUE;

EID: 33845426466     PISSN: 08883270     EISSN: 10961216     Source Type: Journal    
DOI: 10.1016/j.ymssp.2006.06.005     Document Type: Article
Times cited : (127)

References (19)
  • 1
    • 0031276781 scopus 로고    scopus 로고
    • Development of a combined-type tool dynamometer with a piezo-film accelerometer for an ultra-precision lathe
    • Kim J.D., and Kim D.S. Development of a combined-type tool dynamometer with a piezo-film accelerometer for an ultra-precision lathe. Journal of Materials Processing Technology 71 (1997) 360-366
    • (1997) Journal of Materials Processing Technology , vol.71 , pp. 360-366
    • Kim, J.D.1    Kim, D.S.2
  • 3
    • 33845394414 scopus 로고    scopus 로고
    • S.E. Oraby, Mathematical modelling and in-process monitoring techniques for cutting tools, Ph.D. Thesis, University of Sheffield, 1989.
  • 10
    • 0242405507 scopus 로고    scopus 로고
    • A dynamometer design and its construction for milling operation
    • Korkut I. A dynamometer design and its construction for milling operation. Materials Design 24 (2003) 631-637
    • (2003) Materials Design , vol.24 , pp. 631-637
    • Korkut, I.1
  • 11
    • 0036604286 scopus 로고    scopus 로고
    • Design and construction of a dynamometer for measurement of cutting forces during machining with linear motion
    • Şeker U., Kurt A., and Çiftçi I. Design and construction of a dynamometer for measurement of cutting forces during machining with linear motion. Materials Design 23 (2002) 355-360
    • (2002) Materials Design , vol.23 , pp. 355-360
    • Şeker, U.1    Kurt, A.2    Çiftçi, I.3
  • 12
    • 58149205881 scopus 로고
    • A new micro-cutting device with high stiffness and resolution
    • Hara Y., Motonish S., Yoshida K., and Ikawa N. A new micro-cutting device with high stiffness and resolution. Annals of CIRP 39 (1990) 375-378
    • (1990) Annals of CIRP , vol.39 , pp. 375-378
    • Hara, Y.1    Motonish, S.2    Yoshida, K.3    Ikawa, N.4
  • 13
    • 33845447376 scopus 로고    scopus 로고
    • Kistler Instrument Corp. Force Sensors: High-resolution Measurement of Force, Torque and Strain, US, 2004.
  • 14
    • 33845426443 scopus 로고    scopus 로고
    • The Pressure, Strain, and Force Handbook, Omega Press LLC, 1996.
  • 16
    • 28844498340 scopus 로고    scopus 로고
    • A dynamometer design for measurement the cutting forces on turning
    • Yaldi{dotless}z S., and Unsacar F. A dynamometer design for measurement the cutting forces on turning. Measurement 39 (2006) 80-89
    • (2006) Measurement , vol.39 , pp. 80-89
    • Yaldiz, S.1    Unsacar, F.2
  • 17
    • 0020882925 scopus 로고
    • A critical review of sensors for unmanned machining
    • Tlusty J., and Andrews G.C. A critical review of sensors for unmanned machining. CIRP Annals 32 2 (1983) 563-572
    • (1983) CIRP Annals , vol.32 , Issue.2 , pp. 563-572
    • Tlusty, J.1    Andrews, G.C.2
  • 19
    • 33845384582 scopus 로고    scopus 로고
    • Measurement Group Tech Note, Selection and optimising strain gauge excitation voltage, TN 502, 1980.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.