메뉴 건너뛰기




Volumn 35, Issue 6, 2006, Pages 398-406

Development of a cone angle weighted three-dimensional image reconstruction algorithm to reduce cone-beam artefacts

Author keywords

Artefacts; Computed tomography; Cone beam CT; CT imaging

Indexed keywords

MICROSPHERE;

EID: 33845406539     PISSN: 0250832X     EISSN: None     Source Type: Journal    
DOI: 10.1259/dmfr/64593185     Document Type: Article
Times cited : (4)

References (12)
  • 2
    • 0343340400 scopus 로고    scopus 로고
    • 3D cone-beam CT reconstruction for circular trajectory
    • Grass M, Kohler T, Proksa R. 3D cone-beam CT reconstruction for circular trajectory. Phys Med Biol 2000; 45: 329-347.
    • (2000) Phys Med Biol , vol.45 , pp. 329-347
    • Grass, M.1    Kohler, T.2    Proksa, R.3
  • 5
    • 0032596585 scopus 로고    scopus 로고
    • Approximate short-scan filtered backprojection for helical CB reconstruction
    • Noo F, Kudo H, Defrise M. Approximate short-scan filtered backprojection for helical CB reconstruction. IEEE Nuclear Science Symposium 1998; 3: 2073-2077.
    • (1998) IEEE Nuclear Science Symposium , vol.3 , pp. 2073-2077
    • Noo, F.1    Kudo, H.2    Defrise, M.3
  • 6
    • 0342997801 scopus 로고    scopus 로고
    • Clinical benefits of a multi row detector spiral CT system
    • Flohr T. Clinical benefits of a multi row detector spiral CT system. Radiology 1997; 205: 214-215.
    • (1997) Radiology , vol.205 , pp. 214-215
    • Flohr, T.1
  • 7
    • 0032924568 scopus 로고    scopus 로고
    • Multi-slice helical CT: Scan and reconstruction
    • Hu H. Multi-slice helical CT: scan and reconstruction. Med Phys 1999; 26: 5-18.
    • (1999) Med Phys , vol.26 , pp. 5-18
    • Hu, H.1
  • 8
    • 0033452893 scopus 로고    scopus 로고
    • Pitch analysis in multi-slice spiral/helical CT
    • Wang G, Vannier MW. Pitch analysis in multi-slice spiral/helical CT. Med Phys 1999; 26: 2648-2653.
    • (1999) Med Phys , vol.26 , pp. 2648-2653
    • Wang, G.1    Vannier, M.W.2
  • 9
    • 0032422150 scopus 로고    scopus 로고
    • 3D angiography. Clinical interest. First applications in interventional neroradiology
    • Anxionnat R, Bracard S, Macho J, Da Costa E, Vaillant R, Launay L, et al. 3D angiography. Clinical interest. First applications in interventional neroradiology. J Neuroradiol 1998; 25: 251-262.
    • (1998) J Neuroradiol , vol.25 , pp. 251-262
    • Anxionnat, R.1    Bracard, S.2    Macho, J.3    Da Costa, E.4    Vaillant, R.5    Launay, L.6
  • 10
    • 0035191083 scopus 로고    scopus 로고
    • Multiplanar reconstructions and three-dimensional imaging (computed rotational osteography) of complex fractures by using a C-arm system: Initial results
    • El Sheik M, Heverhagen JT, Alfke H, Froelich JJ, Hornegger J, Brunner T, et al. Multiplanar reconstructions and three-dimensional imaging (computed rotational osteography) of complex fractures by using a C-arm system: initial results. Radiology 2001; 221: 843-849.
    • (2001) Radiology , vol.221 , pp. 843-849
    • El Sheik, M.1    Heverhagen, J.T.2    Alfke, H.3    Froelich, J.J.4    Hornegger, J.5    Brunner, T.6
  • 11
    • 0036082380 scopus 로고    scopus 로고
    • Three-dimensional CT with a modified C-arm image intensifier: Feasibility
    • Linsenmaier U, Rock C, Euler E, Wirth S, Brandi R, Kotsianos D. et al. Three-dimensional CT with a modified C-arm image intensifier: feasibility. Radiology 2002; 224: 286-292.
    • (2002) Radiology , vol.224 , pp. 286-292
    • Linsenmaier, U.1    Rock, C.2    Euler, E.3    Wirth, S.4    Brandi, R.5    Kotsianos, D.6
  • 12
    • 0032912554 scopus 로고    scopus 로고
    • Single-slice rebinning method for helical cone-beam CT
    • Noo F, Defrise M, Clack R. Single-slice rebinning method for helical cone-beam CT. Phys Med Biol 1999; 44: 561-570.
    • (1999) Phys Med Biol , vol.44 , pp. 561-570
    • Noo, F.1    Defrise, M.2    Clack, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.