메뉴 건너뛰기




Volumn 19, Issue 1, 2007, Pages 55-60

Ultrasonography and the rheumatologist

Author keywords

Power Doppler; Rheumatoid arthritis; Three dimensional sonography; Training; Ultrasonography

Indexed keywords

ARTHRITIS; BONE EROSION; BURSITIS; CHRONIC DISEASE; DISEASE ACTIVITY; DISEASE COURSE; ECHOGRAPHY; HUMAN; INFLAMMATION; PATHOLOGICAL ANATOMY; PATIENT POSITIONING; PRIORITY JOURNAL; REVIEW; RHEUMATOLOGY; STANDARD; SYNOVITIS; TENDON DISEASE;

EID: 33845356326     PISSN: 10408711     EISSN: None     Source Type: Journal    
DOI: 10.1097/BOR.0b013e3280119648     Document Type: Review
Times cited : (44)

References (42)
  • 3
    • 33645941538 scopus 로고    scopus 로고
    • A rheumatologist's perspective on musculoskeletal ultrasound in rheumatology: Comment on the editorial by Roemer et al.
    • Kane D, Bruyn G, Arnold E, Grassi W. A rheumatologist's perspective on musculoskeletal ultrasound in rheumatology: comment on the editorial by Roemer et al. Arthritis Rheum 2006; 55:341-342. This letter outlines the rheumatologist's perspective on ultrasonography and addresses issues that may be a source of misunderstanding with the radiologists.
    • (2006) Arthritis Rheum , vol.55 , pp. 341-342
    • Kane, D.1    Bruyn, G.2    Arnold, E.3    Grassi, W.4
  • 4
    • 3242875754 scopus 로고    scopus 로고
    • Musculoskeletal ultrasound - A state of the art review in rheumatology. Part 2: Clinical indications for musculoskeletal ultrasound in rheumatology
    • Kane D, Grassi W, Sturrock R, Balint PV. Musculoskeletal ultrasound - a state of the art review in rheumatology. Part 2: clinical indications for musculoskeletal ultrasound in rheumatology. Rheumatology 2004; 43:829-838.
    • (2004) Rheumatology , vol.43 , pp. 829-838
    • Kane, D.1    Grassi, W.2    Sturrock, R.3    Balint, P.V.4
  • 6
    • 13444265887 scopus 로고    scopus 로고
    • Recommendations for musculoskeletal ultrasonography by rheumatologists: Setting global standards for best practice by expert consensus
    • Brown AK, O'Connor PJ, Roberts TE, et al. Recommendations for musculoskeletal ultrasonography by rheumatologists: setting global standards for best practice by expert consensus. Arthritis Rheum 2005; 53:83-92.
    • (2005) Arthritis Rheum , vol.53 , pp. 83-92
    • Brown, A.K.1    O'Connor, P.J.2    Roberts, T.E.3
  • 7
    • 1842453346 scopus 로고    scopus 로고
    • Sonography and subclinical synovitis
    • Bresnihan B, Kane D. Sonography and subclinical synovitis. Ann Rheum Dis 2004; 63:333-334.
    • (2004) Ann Rheum Dis , vol.63 , pp. 333-334
    • Bresnihan, B.1    Kane, D.2
  • 8
    • 1842453334 scopus 로고    scopus 로고
    • Should oligoarthritis be reclassified? Ultrasound reveals a high prevalence of subclinical disease
    • Wakefield RJ, Green MJ, Marzo-Ortega H, et al. Should oligoarthritis be reclassified? Ultrasound reveals a high prevalence of subclinical disease. Ann Rheum Dis 2004; 63:382-385.
    • (2004) Ann Rheum Dis , vol.63 , pp. 382-385
    • Wakefield, R.J.1    Green, M.J.2    Marzo-Ortega, H.3
  • 9
    • 0034541599 scopus 로고    scopus 로고
    • The value of sonography in the detection of bone erosions in patients with rheumatoid arthritis: A comparison with conventional radiography
    • Wakefield RJ, Gibbon WW, Conaghan PG, et al. The value of sonography in the detection of bone erosions in patients with rheumatoid arthritis: a comparison with conventional radiography. Arthritis Rheum 2000; 43:2762-2770.
    • (2000) Arthritis Rheum , vol.43 , pp. 2762-2770
    • Wakefield, R.J.1    Gibbon, W.W.2    Conaghan, P.G.3
  • 10
    • 0035135499 scopus 로고    scopus 로고
    • Ultrasonography in the evaluation of bone erosions
    • Grassi W, Filippucci E, Farina A, et al. Ultrasonography in the evaluation of bone erosions. Ann Rheum Dis 2001; 60:98-103.
    • (2001) Ann Rheum Dis , vol.60 , pp. 98-103
    • Grassi, W.1    Filippucci, E.2    Farina, A.3
  • 11
    • 21144435787 scopus 로고    scopus 로고
    • Rheumatoid and psoriatic knee synovitis: Clinical, grey scale, and power Doppler ultrasound assessment of the response to etanercept
    • Fiocco U, Ferro F, Vezzu M, et al. Rheumatoid and psoriatic knee synovitis: clinical, grey scale, and power Doppler ultrasound assessment of the response to etanercept. Ann Rheum Dis 2005; 64:899-905.
    • (2005) Ann Rheum Dis , vol.64 , pp. 899-905
    • Fiocco, U.1    Ferro, F.2    Vezzu, M.3
  • 12
    • 1842733193 scopus 로고    scopus 로고
    • Comparison of ultrasonographic assessment of synovitis and joint vascularity with radiographic evaluation in a randomized, placebo-controlled study of infliximab therapy in early rheumatoid arthritis
    • Taylor PC, Steuer A, Gruber J, et al. Comparison of ultrasonographic assessment of synovitis and joint vascularity with radiographic evaluation in a randomized, placebo-controlled study of infliximab therapy in early rheumatoid arthritis. Arthritis Rheum 2004; 50:1107-1116.
    • (2004) Arthritis Rheum , vol.50 , pp. 1107-1116
    • Taylor, P.C.1    Steuer, A.2    Gruber, J.3
  • 13
    • 0036786842 scopus 로고    scopus 로고
    • Ultrasonography of entheseal insertions in the lower limb in spondyloarthropathy
    • Balint PV, Kane D, Wilson H, et al. Ultrasonography of entheseal insertions in the lower limb in spondyloarthropathy. Ann Rheum Dis 2002; 61:905-910.
    • (2002) Ann Rheum Dis , vol.61 , pp. 905-910
    • Balint, P.V.1    Kane, D.2    Wilson, H.3
  • 14
    • 20144386614 scopus 로고    scopus 로고
    • Diagnosis of calcium pyrophosphate dihydrate crystal deposition disease: Ultrasonographic criteria proposed
    • Frediani B, Filippou G, Falsetti P, et al. Diagnosis of calcium pyrophosphate dihydrate crystal deposition disease: ultrasonographic criteria proposed. Ann Rheum Dis 2005; 64:638-640.
    • (2005) Ann Rheum Dis , vol.64 , pp. 638-640
    • Frediani, B.1    Filippou, G.2    Falsetti, P.3
  • 15
    • 2942700085 scopus 로고    scopus 로고
    • Carpal tunnel syndrome: Diagnostic usefulness of sonography
    • Wong SM, Griffith JF, Hui AC, et al. Carpal tunnel syndrome: diagnostic usefulness of sonography. Radiology 2004; 232:93-99.
    • (2004) Radiology , vol.232 , pp. 93-99
    • Wong, S.M.1    Griffith, J.F.2    Hui, A.C.3
  • 16
    • 31144449898 scopus 로고    scopus 로고
    • Colour duplex sonography of finger arteries in vasculitis and in systemic sclerosis
    • Schmidt WA, Wernicke D, Kiefer E, Gromnica-Ihle E. Colour duplex sonography of finger arteries in vasculitis and in systemic sclerosis. Ann Rheum Dis 2006; 65:265-267.
    • (2006) Ann Rheum Dis , vol.65 , pp. 265-267
    • Schmidt, W.A.1    Wernicke, D.2    Kiefer, E.3    Gromnica-Ihle, E.4
  • 17
    • 0742305100 scopus 로고    scopus 로고
    • A randomized comparative study of short term response to blind injection versus sonographic-guided injection of local corticosteroids in patients with painful shoulder
    • Naredo E, Cabero F, Beneyto P, et al. A randomized comparative study of short term response to blind injection versus sonographic-guided injection of local corticosteroids in patients with painful shoulder. J Rheumatol 2004; 31:308-314.
    • (2004) J Rheumatol , vol.31 , pp. 308-314
    • Naredo, E.1    Cabero, F.2    Beneyto, P.3
  • 18
    • 17244380959 scopus 로고    scopus 로고
    • Impact of ultrasound imaging on local corticosteroid injections of symptomatic ankle, hind-, and mid-foot in chronic inflammatory diseases
    • D'Agostino MA, Ayral X, Baron G, et al. Impact of ultrasound imaging on local corticosteroid injections of symptomatic ankle, hind-, and mid-foot in chronic inflammatory diseases. Arthritis Rheum 2005; 53:284-292.
    • (2005) Arthritis Rheum , vol.53 , pp. 284-292
    • D'Agostino, M.A.1    Ayral, X.2    Baron, G.3
  • 19
    • 19544367986 scopus 로고    scopus 로고
    • Ultrasound guided synovial biopsy using portal and forceps
    • Koski JM, Helle M. Ultrasound guided synovial biopsy using portal and forceps. Ann Rheum Dis 2005; 64:926-929.
    • (2005) Ann Rheum Dis , vol.64 , pp. 926-929
    • Koski, J.M.1    Helle, M.2
  • 20
    • 11144338783 scopus 로고    scopus 로고
    • Sonography of full-thickness supraspinatus tears: Comparison of patient positioning technique with surgical correlation
    • Ferri M, Finlay K, Popowich T, et al. Sonography of full-thickness supraspinatus tears: comparison of patient positioning technique with surgical correlation. AJR Am J Roentgenol 2005; 184:180-184.
    • (2005) AJR Am J Roentgenol , vol.184 , pp. 180-184
    • Ferri, M.1    Finlay, K.2    Popowich, T.3
  • 21
    • 34247551019 scopus 로고    scopus 로고
    • Ultrasonography of the metacarpophalangeal and proximal interphalangeal joints in rheumatoid arthritis: A comparison with magnetic resonance imaging, conventional radiography and clinical examination
    • Szkudlarek M, Klarlund M, Narvestad E, et al. Ultrasonography of the metacarpophalangeal and proximal interphalangeal joints in rheumatoid arthritis: a comparison with magnetic resonance imaging, conventional radiography and clinical examination. Arthritis Res Ther 2006; 8:R52. This study investigates the sensitivity and specificity of ultrasonography in detecting joint inflammation and destruction in the finger joints of rheumatoid patients using MRI as a reference method.
    • (2006) Arthritis Res Ther , vol.8
    • Szkudlarek, M.1    Klarlund, M.2    Narvestad, E.3
  • 22
    • 20044377610 scopus 로고    scopus 로고
    • Detection and measurement of rotator cuff tears with sonography: Analysis of diagnostic errors
    • Teefey SA, Middleton WD, Payne WT, Yamaguchi K. Detection and measurement of rotator cuff tears with sonography: analysis of diagnostic errors. AJR Am J Roentgenol 2005; 184:1768-1773.
    • (2005) AJR Am J Roentgenol , vol.184 , pp. 1768-1773
    • Teefey, S.A.1    Middleton, W.D.2    Payne, W.T.3    Yamaguchi, K.4
  • 24
    • 33745125065 scopus 로고    scopus 로고
    • Imaging the infrapatellar tendon in the elite athlete
    • Peace KA, Lee JC, Healy J. Imaging the infrapatellar tendon in the elite athlete. Clin Radiol 2006; 61:570-578.
    • (2006) Clin Radiol , vol.61 , pp. 570-578
    • Peace, K.A.1    Lee, J.C.2    Healy, J.3
  • 25
    • 6444226703 scopus 로고    scopus 로고
    • Ultrasonography in osteoarthritis
    • Grassi W, Filippucci E, Farina A. Ultrasonography in osteoarthritis. Semin Arthritis Rheum 2005; 34:19-23. This review illustrates the diagnostic ability and potential of ultrasonography in the assessment of the different pathologic changes in patients with osteoarthritis.
    • (2005) Semin Arthritis Rheum , vol.34 , pp. 19-23
    • Grassi, W.1    Filippucci, E.2    Farina, A.3
  • 26
    • 20944450477 scopus 로고    scopus 로고
    • Ultrasonographic findings in knee osteoarthritis: A comparative study with clinical and radiographic assessment
    • Naredo E, Cabero F, Palop MJ, et al. Ultrasonographic findings in knee osteoarthritis: a comparative study with clinical and radiographic assessment. Osteoarthritis Cartilage 2005; 13:568-574.
    • (2005) Osteoarthritis Cartilage , vol.13 , pp. 568-574
    • Naredo, E.1    Cabero, F.2    Palop, M.J.3
  • 27
    • 25844458179 scopus 로고    scopus 로고
    • Segond fracture revealed by ultrasonography
    • Boutry N, Dupont S, Glaude E, et al. Segond fracture revealed by ultrasonography. J Ultrasound Med 2005; 24:1431-1435.
    • (2005) J Ultrasound Med , vol.24 , pp. 1431-1435
    • Boutry, N.1    Dupont, S.2    Glaude, E.3
  • 28
    • 9344269431 scopus 로고    scopus 로고
    • Sonography of bone and bone-related diseases of the extremities
    • Cho KH, Lee YH, Lee SM, et al. Sonography of bone and bone-related diseases of the extremities. J Clin Ultrasound 2004; 32:511-521.
    • (2004) J Clin Ultrasound , vol.32 , pp. 511-521
    • Cho, K.H.1    Lee, Y.H.2    Lee, S.M.3
  • 29
    • 33745728459 scopus 로고    scopus 로고
    • Ultrasound ability in early diagnosis of stress fracture of metatarsal bone
    • Banal F, Etchepare F, Rouhier B, et al. Ultrasound ability in early diagnosis of stress fracture of metatarsal bone. Ann Rheum Dis 2006; 65:977-978.
    • (2006) Ann Rheum Dis , vol.65 , pp. 977-978
    • Banal, F.1    Etchepare, F.2    Rouhier, B.3
  • 30
    • 28844496964 scopus 로고    scopus 로고
    • Musculoskeletal ultrasound including definitions for ultrasonographic pathology
    • OMERACT 7 Special Interest Group
    • Wakefield RJ, Balint PV, Szkudlarek M, et al. OMERACT 7 Special Interest Group. Musculoskeletal ultrasound including definitions for ultrasonographic pathology. J Rheumatol 2005; 32:2485-2487.
    • (2005) J Rheumatol , vol.32 , pp. 2485-2487
    • Wakefield, R.J.1    Balint, P.V.2    Szkudlarek, M.3
  • 31
    • 29944438969 scopus 로고    scopus 로고
    • Ultrasonographic assessment of inflammatory activity in rheumatoid arthritis: Comparison of extended versus reduced joint evaluation
    • Naredo E, Gamero F, Bonilla G, et al. Ultrasonographic assessment of inflammatory activity in rheumatoid arthritis: comparison of extended versus reduced joint evaluation. Clin Exp Rheumatol 2005; 23:881-884.
    • (2005) Clin Exp Rheumatol , vol.23 , pp. 881-884
    • Naredo, E.1    Gamero, F.2    Bonilla, G.3
  • 32
    • 2442651702 scopus 로고    scopus 로고
    • Greyscale and power Doppler sonographic changes induced by intra-articular steroid injection treatment
    • Filippucci E, Farina A, Carotti M, et al. Greyscale and power Doppler sonographic changes induced by intra-articular steroid injection treatment. Ann Rheum Dis 2004; 63:740-743.
    • (2004) Ann Rheum Dis , vol.63 , pp. 740-743
    • Filippucci, E.1    Farina, A.2    Carotti, M.3
  • 33
    • 0036789126 scopus 로고    scopus 로고
    • Synovial tissue of the hip at power Doppler US: Correlation between vascularity and power Doppler US signal
    • Walther M, Harms H, Krenn V, et al. Synovial tissue of the hip at power Doppler US: correlation between vascularity and power Doppler US signal. Radiology 2002; 225:225-231.
    • (2002) Radiology , vol.225 , pp. 225-231
    • Walther, M.1    Harms, H.2    Krenn, V.3
  • 34
    • 19544377008 scopus 로고    scopus 로고
    • Doppler ultrasound findings in healthy wrists and finger joints before and after use of two different contrast agents
    • Terslev L, Torp-Pedersen S, Bang N, et al. Doppler ultrasound findings in healthy wrists and finger joints before and after use of two different contrast agents. Ann Rheum Dis 2005; 64:824-827.
    • (2005) Ann Rheum Dis , vol.64 , pp. 824-827
    • Terslev, L.1    Torp-Pedersen, S.2    Bang, N.3
  • 35
    • 2442697916 scopus 로고    scopus 로고
    • Doppler ultrasound findings in healthy wrists and finger joints
    • Terslev L, Torp-Pedersen S, Qvistgaard E, et al. Doppler ultrasound findings in healthy wrists and finger joints. Ann Rheum Dis 2004; 63:644-648.
    • (2004) Ann Rheum Dis , vol.63 , pp. 644-648
    • Terslev, L.1    Torp-Pedersen, S.2    Qvistgaard, E.3
  • 36
    • 33751301620 scopus 로고    scopus 로고
    • Power Doppler ultrasonography and synovitis. Correlating ultrasound imaging with histopathological findings and evaluating the performance of ultrasound equipments
    • doi:10.1136/ard.2005.051235
    • Koski JM, Saarakkala S, Helle M, et al. Power Doppler ultrasonography and synovitis. Correlating ultrasound imaging with histopathological findings and evaluating the performance of ultrasound equipments. Ann Rheum Dis 2006 doi:10.1136/ard.2005.051235 This study evaluates power Doppler ability to assess synovitis on different ultrasound systems using histopathological findings as gold standard.
    • (2006) Ann Rheum Dis
    • Koski, J.M.1    Saarakkala, S.2    Helle, M.3
  • 37
    • 3242887726 scopus 로고    scopus 로고
    • Musculoskeletal ultrasonography: What is it and should training be compulsory for rheumatologists?
    • Wakefield RJ, Brown AK, O'Connor PJ, et al. Musculoskeletal ultrasonography: what is it and should training be compulsory for rheumatologists? Rheumatology 2004; 43:821-822.
    • (2004) Rheumatology , vol.43 , pp. 821-822
    • Wakefield, R.J.1    Brown, A.K.2    O'Connor, P.J.3
  • 38
    • 33845563230 scopus 로고    scopus 로고
    • Ultrasonography in rheumatology. Developing its potential in clinical practice and research
    • (in press)
    • Meenagh G, Filippucci E, Kane D, et al. Ultrasonography in rheumatology. Developing its potential in clinical practice and research. Rheumatology (in press).
    • Rheumatology
    • Meenagh, G.1    Filippucci, E.2    Kane, D.3
  • 39
    • 3242884496 scopus 로고    scopus 로고
    • Practice, training and assessment among experts performing musculoskeletal ultrasonography: Toward the development of an international consensus of educational standards for ultrasonography for rheumatologists
    • Brown AK, O'Connor PJ, Wakefield RJ, et al. Practice, training and assessment among experts performing musculoskeletal ultrasonography: toward the development of an international consensus of educational standards for ultrasonography for rheumatologists. Arthritis Rheum 2004; 51:1018-1022.
    • (2004) Arthritis Rheum , vol.51 , pp. 1018-1022
    • Brown, A.K.1    O'Connor, P.J.2    Wakefield, R.J.3
  • 40
    • 29844458544 scopus 로고    scopus 로고
    • Musculoskeletal ultrasound training in rheumatology: The Belfast experience
    • Taggart A, Filippucci E, Wright G, et al. Musculoskeletal ultrasound training in rheumatology: the Belfast experience. Rheumatology 2006; 45:102-105. This paper outlines the steps followed by a group of rheumatologists from the Regional Rheumatology Centre in Belfast to acquire both ultrasonography systems and basic competency in musculoskeletal ultrasonography in rheumatology.
    • (2006) Rheumatology , vol.45 , pp. 102-105
    • Taggart, A.1    Filippucci, E.2    Wright, G.3
  • 41
    • 33646227675 scopus 로고    scopus 로고
    • Ultrasonography for rheumatologists: The development of specific competency based educational outcomes
    • Brown AK, O'Connor PJ, Roberts TE, et al. Ultrasonography for rheumatologists: the development of specific competency based educational outcomes. Ann Rheum Dis 2006; 65:629-636. This paper delineates the educational outcomes in ultrasonography developed according to specific competency for the rheumatologist.
    • (2006) Ann Rheum Dis , vol.65 , pp. 629-636
    • Brown, A.K.1    O'Connor, P.J.2    Roberts, T.E.3
  • 42
    • 20944443258 scopus 로고    scopus 로고
    • Interobserver reliability of rheumatologists performing musculoskeletal ultrasonography: Results from a EULAR 'Train the trainers' course
    • Scheel AK, Schmidt WA, Hermann KG, et al. Interobserver reliability of rheumatologists performing musculoskeletal ultrasonography: results from a EULAR 'Train the trainers' course. Ann Rheum Dis 2005; 64:1043-1049.
    • (2005) Ann Rheum Dis , vol.64 , pp. 1043-1049
    • Scheel, A.K.1    Schmidt, W.A.2    Hermann, K.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.