메뉴 건너뛰기




Volumn 14, Issue 6, 2006, Pages 467-471

Late re-operation for aortic and mitral Starr-Edwards ball valve prostheses

Author keywords

[No Author keywords available]

Indexed keywords

BILIRUBIN; HEMOGLOBIN; LACTATE DEHYDROGENASE; WARFARIN;

EID: 33845352347     PISSN: 02184923     EISSN: None     Source Type: Journal    
DOI: 10.1177/021849230601400605     Document Type: Article
Times cited : (2)

References (13)
  • 1
    • 33748207077 scopus 로고
    • Mitral replacement: Clinical experience with a ball-valve prosthesis
    • Starr A, Edwards ML. Mitral replacement: clinical experience with a ball-valve prosthesis. Ann Surg 1961;154:726-40.
    • (1961) Ann Surg , vol.154 , pp. 726-740
    • Starr, A.1    Edwards, M.L.2
  • 2
    • 13144254285 scopus 로고    scopus 로고
    • Macroscopic aspects of cloth-covered Starr-Edwards prostheses at reoperation: What the precursory valve teaches us
    • Tsukamoto S, Shiono M, Orime Y, Hata H, Yagi S, Okumura H, et al. Macroscopic aspects of cloth-covered Starr-Edwards prostheses at reoperation: what the precursory valve teaches us. J Heart Valve Dis 1998;7:556-60.
    • (1998) J Heart Valve Dis , vol.7 , pp. 556-560
    • Tsukamoto, S.1    Shiono, M.2    Orime, Y.3    Hata, H.4    Yagi, S.5    Okumura, H.6
  • 3
    • 0018082687 scopus 로고
    • Complications due to cloth wear in cloth-covered Starr-Edwards aortic and mitral valve prostheses - And their management
    • Shah A, Dolgin M, Tice DA, Trehan N. Complications due to cloth wear in cloth-covered Starr-Edwards aortic and mitral valve prostheses - and their management. Am Heart J 1978;96:407-14.
    • (1978) Am Heart J , vol.96 , pp. 407-414
    • Shah, A.1    Dolgin, M.2    Tice, D.A.3    Trehan, N.4
  • 4
    • 0025506761 scopus 로고
    • Cerebral and myocardial infarcts due to deterioration of cloth-cover of Starr-Edwards mitral valve 16 years after replacement
    • Akiyama K, Anzai N. Cerebral and myocardial infarcts due to deterioration of cloth-cover of Starr-Edwards mitral valve 16 years after replacement. Nippon Kyobu Geka Gakkai Zasshi 1990;38:2133-6.
    • (1990) Nippon Kyobu Geka Gakkai Zasshi , vol.38 , pp. 2133-2136
    • Akiyama, K.1    Anzai, N.2
  • 7
    • 0036278101 scopus 로고    scopus 로고
    • Severe hemolysis due to cloth wear 23 years after aortic valve replacement on a Starr-Edwards ball valve model 2320
    • Murakami M, Tanaka H, Watanabe M, Shimizu M, Sunamori M. Severe hemolysis due to cloth wear 23 years after aortic valve replacement on a Starr-Edwards ball valve model 2320. Cardiovasc Surg 2002;10:284-6.
    • (2002) Cardiovasc Surg , vol.10 , pp. 284-286
    • Murakami, M.1    Tanaka, H.2    Watanabe, M.3    Shimizu, M.4    Sunamori, M.5
  • 8
    • 0016201331 scopus 로고
    • Mitral valve replacement Starr-Edwards cloth-covered composite-seat prosthesis
    • Allen WB, Karp RB, Kouchoukos NT. Mitral valve replacement Starr-Edwards cloth-covered composite-seat prosthesis. Arch Surg 1974;109:642-7.
    • (1974) Arch Surg , vol.109 , pp. 642-647
    • Allen, W.B.1    Karp, R.B.2    Kouchoukos, N.T.3
  • 9
    • 0022576922 scopus 로고
    • Late ball variance with the Model 1000 Starr-Edwards aortic valve prosthesis. Risk analysis and strategy of operative management
    • Grunkemeier GL, Starr A. Late ball variance with the Model 1000 Starr-Edwards aortic valve prosthesis. Risk analysis and strategy of operative management. J Thorac Cardiovasc Surg 1986;91:918-23.
    • (1986) J Thorac Cardiovasc Surg , vol.91 , pp. 918-923
    • Grunkemeier, G.L.1    Starr, A.2
  • 10
    • 0036781561 scopus 로고    scopus 로고
    • Reoperation for a patient 25 years after a Starr-Edwards ball mitral valve was installed
    • Ye Z, Shiono M, Sezai A, Inoue T, Hata M, Niino T, et al. Reoperation for a patient 25 years after a Starr-Edwards ball mitral valve was installed. Ann Thorac Cardiovasc Surg 2002;8:311-5.
    • (2002) Ann Thorac Cardiovasc Surg , vol.8 , pp. 311-315
    • Ye, Z.1    Shiono, M.2    Sezai, A.3    Inoue, T.4    Hata, M.5    Niino, T.6
  • 11
    • 0016695660 scopus 로고
    • Aortic and mitral valve replacement with cloth-covered Braunwald-Cutter prosthesis. A three-year follow-up
    • Pluth JR, Broadbent JC, Barnhorst DA, Danielson GK. Aortic and mitral valve replacement with cloth-covered Braunwald-Cutter prosthesis. A three-year follow-up. Ann Thorac Surg 1975;20:239-48.
    • (1975) Ann Thorac Surg , vol.20 , pp. 239-248
    • Pluth, J.R.1    Broadbent, J.C.2    Barnhorst, D.A.3    Danielson, G.K.4
  • 13
    • 0015058594 scopus 로고
    • Thromboembolic complications of heart valve prostheses
    • Friedli B, Aerichide N, Grondin P, Campeau L. Thromboembolic complications of heart valve prostheses. Am Heart J 1971;81:702-8.
    • (1971) Am Heart J , vol.81 , pp. 702-708
    • Friedli, B.1    Aerichide, N.2    Grondin, P.3    Campeau, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.