메뉴 건너뛰기




Volumn 29, Issue 3, 2007, Pages 291-297

Biomedical sensor using thick film technology for transcutaneous oxygen measurement

Author keywords

Polyelectrolyte; Screen printed; Transcutaneous oxygen

Indexed keywords

BIOMEDICAL ENGINEERING; BLOOD; BLOOD GAS ANALYSIS; COSTS; ELECTROCHEMICAL ELECTRODES; OXYGEN; PATIENT MONITORING; POLYELECTROLYTES; THICK FILM DEVICES;

EID: 33845333040     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.medengphy.2006.03.010     Document Type: Article
Times cited : (13)

References (17)
  • 1
    • 0028451061 scopus 로고
    • The oxygen-carrying flask: a representational transform of the oxygen dissociation curve of haemoglobin
    • Sircar S.S. The oxygen-carrying flask: a representational transform of the oxygen dissociation curve of haemoglobin. Adv Physiol Educ 266 (1994) 33-35
    • (1994) Adv Physiol Educ , vol.266 , pp. 33-35
    • Sircar, S.S.1
  • 2
    • 33845302011 scopus 로고    scopus 로고
    • 2 monitoring in neonatology, 1994.
  • 4
    • 0032932450 scopus 로고    scopus 로고
    • Pulse oximetry: principles and limitations
    • Sinex J.E. Pulse oximetry: principles and limitations. Am J Emerg Med 17 1 (1999) 59-67
    • (1999) Am J Emerg Med , vol.17 , Issue.1 , pp. 59-67
    • Sinex, J.E.1
  • 5
    • 0024518487 scopus 로고
    • Neonatal pulse oximetry: accuracy and reliability
    • Hay W.W., Brockway J.M., and Eyzaguirre M. Neonatal pulse oximetry: accuracy and reliability. Pediatrics 83 5 (1989) 717-722
    • (1989) Pediatrics , vol.83 , Issue.5 , pp. 717-722
    • Hay, W.W.1    Brockway, J.M.2    Eyzaguirre, M.3
  • 7
    • 84942558425 scopus 로고
    • Monitor and control of blood and tissue oxygen tensions
    • Clark L.C. Monitor and control of blood and tissue oxygen tensions. Trans Am Soc Art Int Org 2 (1956) 41-57
    • (1956) Trans Am Soc Art Int Org , vol.2 , pp. 41-57
    • Clark, L.C.1
  • 8
    • 0004258718 scopus 로고
    • Southampton Electrochemistry Group, Ellis Horwood Ltd. p. 149, ISBN 0134720938 pbk
    • Southampton Electrochemistry Group. Instrumental methods in electrochemistry (1985), Ellis Horwood Ltd. p. 149, ISBN 0134720938 pbk
    • (1985) Instrumental methods in electrochemistry
  • 9
    • 0142011646 scopus 로고    scopus 로고
    • Transient and steady-state responses of thick-film oxygen sensors
    • Lam Y.Z., and Atkinson J.K. Transient and steady-state responses of thick-film oxygen sensors. Measurement 34 (2003) 355-361
    • (2003) Measurement , vol.34 , pp. 355-361
    • Lam, Y.Z.1    Atkinson, J.K.2
  • 10
    • 0019622543 scopus 로고
    • Theoretical basis of the transcutaneous blood gas measurements
    • Lubbers D.W. Theoretical basis of the transcutaneous blood gas measurements. Crit Care Med. 9 10 (1981) 721-733
    • (1981) Crit Care Med. , vol.9 , Issue.10 , pp. 721-733
    • Lubbers, D.W.1
  • 11
    • 0020210790 scopus 로고
    • Continuous transcutaneous oxygen and carbon dioxide monitoring in the pediatric ICU
    • Monaco F., Nickerson B.G., and McQuitty J.C. Continuous transcutaneous oxygen and carbon dioxide monitoring in the pediatric ICU. Crit Care Med 10 (1982) 765-766
    • (1982) Crit Care Med , vol.10 , pp. 765-766
    • Monaco, F.1    Nickerson, B.G.2    McQuitty, J.C.3
  • 12
    • 0022559382 scopus 로고
    • A thick-film multiple component cathode three-electrode oxygen sensor
    • Karagounis V., Liu L., and Liu C.C. A thick-film multiple component cathode three-electrode oxygen sensor. IEEE Trans Biomed Eng 33 BME-2 (1986) 108-112
    • (1986) IEEE Trans Biomed Eng , vol.33 , Issue.BME-2 , pp. 108-112
    • Karagounis, V.1    Liu, L.2    Liu, C.C.3
  • 14
    • 33845298606 scopus 로고    scopus 로고
    • ® PFSA Membranes N-117 Perfluorosulfonic Acid Polymer product information, NAE101, 2002.
  • 15
    • 0036991954 scopus 로고    scopus 로고
    • Disposable screen-printed biosensor for transcutaneous oxygen measurement
    • Lam Y.-Z., and Atkinson J. Disposable screen-printed biosensor for transcutaneous oxygen measurement. Meas Sci Technol 13 (2002) 2074-2081
    • (2002) Meas Sci Technol , vol.13 , pp. 2074-2081
    • Lam, Y.-Z.1    Atkinson, J.2
  • 16
    • 0041807943 scopus 로고    scopus 로고
    • Screen-printed transcutaneous oxygen sensor employing polymer electrolytes
    • Lam Y.Z., and Atkinson J.K. Screen-printed transcutaneous oxygen sensor employing polymer electrolytes. IEE Med Biol Comput Eng J 41 (2003) 456-463
    • (2003) IEE Med Biol Comput Eng J , vol.41 , pp. 456-463
    • Lam, Y.Z.1    Atkinson, J.K.2
  • 17
    • 0019475973 scopus 로고
    • The sweat test: sodium and chloride values
    • Shwachman H., Mahmoodian A., and Neff R.K. The sweat test: sodium and chloride values. J Pediatr 98 (1981) 576-578
    • (1981) J Pediatr , vol.98 , pp. 576-578
    • Shwachman, H.1    Mahmoodian, A.2    Neff, R.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.