Volumn 50, Issue 8, 2006, Pages 813-819

Collection, validation and generation of bitumen fumes for inhalation studies in rats part 3: Regeneration of bitumen fumes, inhalation setup, validation

Author keywords

Asphalt; Bitumen; Chemical analysis; Fume; Polycyclic aromatic hydrocarbons; Workplace

Indexed keywords

ATMOSPHERIC WORKPLACE; BITUMEN; EXPOSURE; FUME;

EID: 33845269565     PISSN: 00034878     EISSN: 14753162     Source Type: Journal    
DOI: 10.1093/annhyg/mel055     Document Type: Article
Times cited : (13)

References (10)
  • 2
    • 0033622926 scopus 로고    scopus 로고
    • Inhalation study on exposure to bitumen fumes, Part 1: Development and validation of the equipment
    • Bonnet P, Binet S, Brandt H et al. (2000) Inhalation study on exposure to bitumen fumes, Part 1: Development and validation of the equipment, Ann Occup Hyg; 44: 15-29.
    • (2000) Ann Occup Hyg , vol.44 , pp. 15-29
    • Bonnet, P.1    Binet, S.2    Brandt, H.3
  • 3
    • 18744398165 scopus 로고    scopus 로고
    • Development and validation of a new bitumen fume generation system which generates polycyclic aromatic hydrocarbon concentrations proportional to fume concentrations
    • Binet S, Bonnet P, Brandt H et al. (2002) Development and validation of a new bitumen fume generation system which generates polycyclic aromatic hydrocarbon concentrations proportional to fume concentrations. Ann Occup Hyg; 46: 617-28.
    • (2002) Ann Occup Hyg , vol.46 , pp. 617-628
    • Binet, S.1    Bonnet, P.2    Brandt, H.3
  • 5
    • 33845242815 scopus 로고    scopus 로고
    • A laboratory rig for studying aspects of worker exposure to bitumen fumes
    • Brandt HCA, de Groot PC (1999) A laboratory rig for studying aspects of worker exposure to bitumen fumes. Am Ind Hyg Assoc J; 60: 182-90.
    • (1999) Am Ind Hyg Assoc J , vol.60 , pp. 182-190
    • Brandt, H.C.A.1    De Groot, P.C.2
  • 6
    • 0034773633 scopus 로고    scopus 로고
    • International studies to compare methods for personal sampling of bitumen fumes
    • Ekström L-G, Kriech A, Bowen C et al. (2001) International studies to compare methods for personal sampling of bitumen fumes. J Environ Monit; 3: 439-45.
    • (2001) J Environ Monit , vol.3 , pp. 439-445
    • Ekström, L.-G.1    Kriech, A.2    Bowen, C.3
  • 7
    • 0034269810 scopus 로고    scopus 로고
    • Comparison of particle-size distributions of bitumen fumes measured by aerosizer® and QCM impactor techniques
    • Fabries JF, Wrobel R, Gorner P et al. (2000) Comparison of particle-size distributions of bitumen fumes measured by aerosizer® and QCM impactor techniques. J Aerosol Sci; 31: SI011-2.
    • (2000) J Aerosol Sci , vol.31
    • Fabries, J.F.1    Wrobel, R.2    Gorner, P.3
  • 9
    • 7944226336 scopus 로고    scopus 로고
    • Total versus inhalable sampler comparison study for the determination of asphalt fume exposures within the road paving industry
    • Kriech AJ, Osborn LV, Wissel HL et al. (2004) Total versus inhalable sampler comparison study for the determination of asphalt fume exposures within the road paving industry. J Environ Monit; 6: 827-33.
    • (2004) J Environ Monit , vol.6 , pp. 827-833
    • Kriech, A.J.1    Osborn, L.V.2    Wissel, H.L.3
  • 10
    • 33845260340 scopus 로고    scopus 로고
    • Collection, validation and generation of bitumen fumes for inhalation studies in rats. Part 1: Workplace samples and validation criteria
    • in press
    • Preiss A, Koch W, Kock H et al. (2006) Collection, validation and generation of bitumen fumes for inhalation studies in rats. Part 1: workplace samples and validation criteria. Ann Occup Hyg; in press.
    • (2006) Ann Occup Hyg
    • Preiss, A.1    Koch, W.2    Kock, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.