메뉴 건너뛰기




Volumn 30, Issue 1, 2007, Pages 43-49

Circulation concentration of CO2/propane mixtures and the effect of their charge on the cooling performance in an air-conditioning system

Author keywords

Air conditioning; Binary mixture; Carbon dioxide; Concentration; Cooling system; Experiment; Parameter; Performance; Propane; Refrigerant

Indexed keywords

AIR CONDITIONING; CARBON DIOXIDE; CONCENTRATION (PROCESS); COOLING SYSTEMS; GLOBAL WARMING; PROPANE; REFRIGERATION; THERMODYNAMIC PROPERTIES;

EID: 33845220847     PISSN: 01407007     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrefrig.2006.06.008     Document Type: Article
Times cited : (62)

References (12)
  • 4
    • 33845216270 scopus 로고    scopus 로고
    • J. Chen, The use of mixed refrigerants to save power in air conditioning and heat pumps, Ph.D. thesis, University of Leeds, UK, 1992.
  • 5
    • 33845232086 scopus 로고    scopus 로고
    • T. Tiedemann, H. Kruse, Evaluation of zeotropic hydrocarbon mixtures in a Lorenz-Meutzner cycle refrigerator freezer, in: Proceedings of the International Institute of Refrigeration Conference, 1994, pp. 607-620.
  • 6
    • 33845228431 scopus 로고    scopus 로고
    • B.O. Hivet, C. Gillet, HFC 134a and HCFC 22/142b mixture for conversion of CFC12 heat pumps, in: Proceedings of the International Refrigeration Conference at Purdue, 1994, pp. 159-164.
  • 7
    • 0029346539 scopus 로고
    • Calculating circulation concentration of zeotropic refrigerant mixtures
    • Chen J., and Kruse H. Calculating circulation concentration of zeotropic refrigerant mixtures. HVAC&R Research 1 3 (1995) 219-231
    • (1995) HVAC&R Research , vol.1 , Issue.3 , pp. 219-231
    • Chen, J.1    Kruse, H.2
  • 8
    • 0031122909 scopus 로고    scopus 로고
    • Concentration shift simulation for the mixed refrigerants R404A, R32/134a, and R407C in an air conditioning system
    • Chen J., and Kruse H. Concentration shift simulation for the mixed refrigerants R404A, R32/134a, and R407C in an air conditioning system. HVAC&R Research 3 2 (1997) 149-157
    • (1997) HVAC&R Research , vol.3 , Issue.2 , pp. 149-157
    • Chen, J.1    Kruse, H.2
  • 9
    • 27644568195 scopus 로고    scopus 로고
    • Vapor-liquid equilibria for the carbon dioxide + propane system over a temperature range from 253.15 to 323.15 K
    • Kim J.H., and Kim M.S. Vapor-liquid equilibria for the carbon dioxide + propane system over a temperature range from 253.15 to 323.15 K. Fluid Phase Equilibria 238 1 (2005) 13-19
    • (2005) Fluid Phase Equilibria , vol.238 , Issue.1 , pp. 13-19
    • Kim, J.H.1    Kim, M.S.2
  • 10
    • 33845213646 scopus 로고    scopus 로고
    • ANSI/ASME, Measurement uncertainty, ANSI/ASME PTC 19.1-1985, Part 1.
  • 11
    • 70349529815 scopus 로고    scopus 로고
    • Reference fluid thermodynamic and transport properties (REFPROP)
    • National Institute of Standards and Technology, Gaithersburg, Maryland, USA
    • Lemmon E.W., McLinden M.O., and Huber M.L. Reference fluid thermodynamic and transport properties (REFPROP). NIST Standard Reference Database 23, Version 7.0 (2002), National Institute of Standards and Technology, Gaithersburg, Maryland, USA
    • (2002) NIST Standard Reference Database 23, Version 7.0
    • Lemmon, E.W.1    McLinden, M.O.2    Huber, M.L.3
  • 12
    • 0035546316 scopus 로고    scopus 로고
    • Rationally based model for evaluating the optimal refrigerant mass charge in refrigerating machines
    • Vjacheslav N., Rozhentsev A., and Wang C.C. Rationally based model for evaluating the optimal refrigerant mass charge in refrigerating machines. Energy Conversion and Management 42 (2001) 2083-2095
    • (2001) Energy Conversion and Management , vol.42 , pp. 2083-2095
    • Vjacheslav, N.1    Rozhentsev, A.2    Wang, C.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.