메뉴 건너뛰기




Volumn 23, Issue 3, 1997, Pages 4238-4242

USP dissolution calibrator tablets - Recommendations for reduced dissolution calibration testing

Author keywords

[No Author keywords available]

Indexed keywords


EID: 33845211578     PISSN: 03634655     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (11)
  • 1
    • 84962073694 scopus 로고    scopus 로고
    • USP Dissolution Calibration Tablets-Is it Time to Reduce the Amount of Testing Required to Calibrate Apparatus 1 and 2?
    • Lindauer RF. USP Dissolution Calibration Tablets-Is it Time to Reduce the Amount of Testing Required to Calibrate Apparatus 1 and 2? Pharm Forum 1996; 21(5):1397-1402.
    • (1996) Pharm Forum , vol.21 , Issue.5 , pp. 1397-1402
    • Lindauer, R.F.1
  • 2
    • 0028898199 scopus 로고
    • A Critical Assessment of the USP Dissolution Apparatus Suitability Test Criteria
    • Qureshi SA, McGilveray IJ. A Critical Assessment of the USP Dissolution Apparatus Suitability Test Criteria. Drug Dev and Ind Pharm 1995; 21(8):905-924.
    • (1995) Drug Dev and Ind Pharm , vol.21 , Issue.8 , pp. 905-924
    • Qureshi, S.A.1    McGilveray, I.J.2
  • 3
    • 33845185965 scopus 로고
    • Calibration of Dissolution Rate Apparatuses: A User's Perspective
    • Skoug JW. Calibration of Dissolution Rate Apparatuses: A User's Perspective. Dissolution Technologies 1994; l(2):3-5.
    • (1994) Dissolution Technologies , vol.2 , pp. 3-5
    • Skoug, J.W.1
  • 4
    • 33845195844 scopus 로고    scopus 로고
    • Workshop Report-AAPS/USP Workshop on Dissolution Calibration and Testing
    • Workshop Report-AAPS/USP Workshop on Dissolution Calibration and Testing. Pharm Res 1996; 13(1):69.
    • (1996) Pharm Res , vol.13 , Issue.1 , pp. 69
  • 5
    • 0020634628 scopus 로고
    • Systematic Error Associated with Apparatus 2 of the USP Dissolution Test III: Limitations of Calibrators and the USP Suitability Test
    • Cox DC, Furman WB, Thornton LK, Moore TWO, Jefferson HE. Systematic Error Associated with Apparatus 2 of the USP Dissolution Test III: Limitations of Calibrators and the USP Suitability Test. J Pharm Sciences 1983; 72(8):910-913.
    • (1983) J Pharm Sciences , vol.72 , Issue.8 , pp. 910-913
    • Cox, D.C.1    Furman, W.B.2    Thornton, L.K.3    Two, M.4    Jefferson, H.E.5
  • 6
    • 0000828169 scopus 로고    scopus 로고
    • Dissolution Calibrator Tablets: A Recommendation for New Calibrator Tablets to Replace Both Current USP Calibrator Tablets
    • Moore TWO, Tango RFD, Habit Y. Dissolution Calibrator Tablets: A Recommendation for New Calibrator Tablets to Replace Both Current USP Calibrator Tablets. Pharm Forum 1996; 22(3):2423-2428.
    • (1996) Pharm Forum , vol.22 , Issue.3 , pp. 2423-2428
    • Moore, T.W.O.1    Tango, R.F.D.2    Habit, Y.3
  • 7
    • 33845191613 scopus 로고
    • Reproducibility of Dissolution Test Results
    • Hamilton JF, Moore TWO, Kerner CM. Reproducibility of Dissolution Test Results. Pharm Forum 1995; 21(5):1383-1386.
    • (1995) Pharm Forum , vol.21 , Issue.5 , pp. 1383-1386
    • Hamilton, J.F.1    Two, M.2    Kerner, C.M.3
  • 8
    • 0000185070 scopus 로고
    • Calibration of Dissolution Apparatuses 1 and 2-What to Do When Your Equipment Fails
    • Gray VA, Hubert BB, Krasowski, JA. Calibration of Dissolution Apparatuses 1 and 2-What To Do When Your Equipment Fails. Pharm Forum 1994; 20(6):8571-8573.
    • (1994) Pharm Forum , vol.20 , Issue.6 , pp. 8571-8573
    • Gray, V.A.1    Hubert, B.B.2    Krasowski, J.A.3
  • 9
    • 33845230067 scopus 로고
    • Report of the Pharmaceutical Research and Manufacturers of America
    • The USP Dissolution Calibrator Collaborative StudyAn Overview of the 1994 Process. Report of the Pharmaceutical Research and Manufacturers of America. Pharm Forum 1994; 20(5):8177-8201.
    • (1994) Pharm Forum , vol.20 , Issue.5 , pp. 8177-8201
  • 10
    • 33845231785 scopus 로고    scopus 로고
    • The 1989 and 1991 test results were provided by David Whiteman (Hoechst Marion Roussel and member of the PhRMA Dissolution Committee). A published source is not available.
    • A Published Source Is Not Available.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.