메뉴 건너뛰기




Volumn 4, Issue 2, 2004, Pages 133-142

Assessment of the ergonomic quality of file handles using electromyographic and subjective methods

Author keywords

Electromyography; Hand tools; Product ergonomics; Subjective assessment

Indexed keywords


EID: 33845192360     PISSN: 13599364     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (15)
  • 2
    • 0028577882 scopus 로고    scopus 로고
    • Ergonomic assessment of handle design by means of electromyography and subjective rating
    • J. Böhlemann, K. Kluth, K. Kotzbauer and H. Strasser, Ergonomic assessment of handle design by means of electromyography and subjective rating, Applied Ergonomics 25(6) (1996), 346-354.
    • (1996) Applied Ergonomics , vol.25 , Issue.6 , pp. 346-354
    • Böhlemann, J.1    Kluth, K.2    Kotzbauer, K.3    Strasser, H.4
  • 3
    • 55449127660 scopus 로고
    • File handles
    • DIN 395. Beuth Verlag, Berlin, December
    • DIN 395, File handles. Beuth Verlag, Berlin, German Standard, December 1968.
    • (1968) German Standard
  • 4
    • 0344398856 scopus 로고    scopus 로고
    • Ergonomic evaluation of an armrest for typing via electromyographic and subjective assessment
    • A. Mital, H. Krueger, S. Kumar, M. Menozzi and J.E. Fernandez, eds, ISOES, Cincinnati/Ohio, USA
    • E. Keller and H. Strasser, Ergonomic evaluation of an armrest for typing via electromyographic and subjective assessment, in: Advances in Occupational Ergonomics and Safety I, A. Mital, H. Krueger, S. Kumar, M. Menozzi and J.E. Fernandez, eds, ISOES, Cincinnati/Ohio, USA, 1996, pp. 838-845.
    • (1996) Advances in Occupational Ergonomics and Safety I , pp. 838-845
    • Keller, E.1    Strasser, H.2
  • 6
    • 0006691410 scopus 로고    scopus 로고
    • S. Kumar and A. Mital, eds, Taylor & Francis, London
    • S. Kumar and A. Mital, eds, Electromyography in Ergonomics, Taylor & Francis, London, 1996.
    • (1996) Electromyography in Ergonomics
  • 7
    • 0041872141 scopus 로고
    • The preparation, recording, and analysis of the EMG signal
    • S. Asfour, ed., Human Factors IV, Elsevier, Amsterdam
    • W.S. Marras, The preparation, recording, and analysis of the EMG signal, in: Trends in ergonomics, S. Asfour, ed., Human Factors IV, Elsevier, Amsterdam, 1987, pp. 701-707.
    • (1987) Trends in Ergonomics , pp. 701-707
    • Marras, W.S.1
  • 8
    • 0025896719 scopus 로고
    • Quantification of EMG normalization error
    • G.A. Mirka, Quantification of EMG normalization error, Ergonomics 34(3) (1991), 343-352.
    • (1991) Ergonomics , vol.34 , Issue.3 , pp. 343-352
    • Mirka, G.A.1
  • 9
    • 55449107083 scopus 로고
    • Ein normierungsverfahren der elektromyographischen aktivität zur beurteilung dynamischer muskelbeanspruchung
    • 4
    • K.-W. Müller, J. Ernst and H. Strasser, Ein Normierungsverfahren der Elektromyographischen Aktivität zur Beurteilung dynamischer Muskelbeanspruchung, Z. Arb. wiss. 43(15NF) 4 (1989), 129-135.
    • (1989) Z. Arb. Wiss. , vol.43 , Issue.15 NF , pp. 129-135
    • Müller, K.-W.1    Ernst, J.2    Strasser, H.3
  • 10
    • 55449127098 scopus 로고    scopus 로고
    • (Arbeitsschutzgesetzt - Gesetz über die Durchführung von Maßahmen des Arbeitsschutzes zur Verbesserung der Sicherheit und des Gesundheitsschutzes vom 07.08.1996, zuletzt geändert am 19.12.1998). BGBII
    • Occupational Health and Safety Act (Arbeitsschutzgesetzt - Gesetz über die Durchführung von Maßahmen des Arbeitsschutzes zur Verbesserung der Sicherheit und des Gesundheitsschutzes vom 07.08.1996, zuletzt geändert am 19.12.1998). BGBII, 1998, p. 2843.
    • (1998) Occupational Health and Safety Act , pp. 2843
  • 11
    • 0011802449 scopus 로고
    • Different grips of screwdrivers evaluated by means of measuring maximum torque, subjective rating and by registering electromyographic data during static and dynamic test work
    • W. Karwowski and J.W. Yates, eds, Taylor & Francis, London
    • H. Strasser, Different grips of screwdrivers evaluated by means of measuring maximum torque, subjective rating and by registering electromyographic data during static and dynamic test work, in: Advances in Industrial Ergonomics and Safety III, W. Karwowski and J.W. Yates, eds, Taylor & Francis, London, 1991, pp. 413-420.
    • (1991) Advances in Industrial Ergonomics and Safety III , pp. 413-420
    • Strasser, H.1
  • 12
    • 84988767762 scopus 로고    scopus 로고
    • Electromyography of upper extremity muscles and ergonomic applications
    • S. Kumar and A. Mital, eds, Taylor & Francis, London
    • H. Strasser, Electromyography of upper extremity muscles and ergonomic applications, in: Electromyography in Ergonomics, S. Kumar and A. Mital, eds, Taylor & Francis, London, 1996, pp. 183-226.
    • (1996) Electromyography in Ergonomics , pp. 183-226
    • Strasser, H.1
  • 14
    • 33644625016 scopus 로고    scopus 로고
    • Work physiology and ergonomics in Germany: From the past to future challenges
    • H. Strasser, Work physiology and ergonomics in Germany: From the past to future challenges, Occupational Ergonomics 3(1) (2002/2003), 19-44.
    • (2002) Occupational Ergonomics , vol.3 , Issue.1 , pp. 19-44
    • Strasser, H.1
  • 15
    • 33644632413 scopus 로고    scopus 로고
    • A computer-based system for the use of electromyographic methods for the measurement of physiological costs associated with operating hand-held tools and computer input devices
    • H. Strasser, K. Kluth and E. Keller, A computer-based system for the use of electromyographic methods for the measurement of physiological costs associated with operating hand-held tools and computer input devices, Occupational Ergonomics 4(2) (2004), 73-87.
    • (2004) Occupational Ergonomics , vol.4 , Issue.2 , pp. 73-87
    • Strasser, H.1    Kluth, K.2    Keller, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.