메뉴 건너뛰기




Volumn 38, Issue 2, 2007, Pages 535-539

Formation of bone-like apatite on titanium filaments incubated in a simulated body fluid by using an electrochemical method

Author keywords

B. Strength; E. Heat treatment

Indexed keywords

BONE; ELECTRIC LOADS; ELECTRODEPOSITION; GRANULAR MATERIALS; TITANIUM;

EID: 33751543369     PISSN: 1359835X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.compositesa.2006.02.013     Document Type: Article
Times cited : (18)

References (22)
  • 2
    • 32644467963 scopus 로고    scopus 로고
    • Formation of bone-like apatite on titanium filament by a simulated body fluid inducing process
    • Lin J.H., Chang C.H., Chen Y.S., and Lin G.T. Formation of bone-like apatite on titanium filament by a simulated body fluid inducing process. Surf Coat Technol 200 12-13 (2006) 3665-3669
    • (2006) Surf Coat Technol , vol.200 , Issue.12-13 , pp. 3665-3669
    • Lin, J.H.1    Chang, C.H.2    Chen, Y.S.3    Lin, G.T.4
  • 3
    • 0036020049 scopus 로고    scopus 로고
    • The effect of Ca/P concentration and temperature of simulated body fluid on the growth of hydroxyapatite coating on alkali-treated 316L stainless steel
    • Lin F.H., Hsu Y.S., Lin S.H., and Sun J.S. The effect of Ca/P concentration and temperature of simulated body fluid on the growth of hydroxyapatite coating on alkali-treated 316L stainless steel. Biomaterials 23 19 (2002) 4029-4038
    • (2002) Biomaterials , vol.23 , Issue.19 , pp. 4029-4038
    • Lin, F.H.1    Hsu, Y.S.2    Lin, S.H.3    Sun, J.S.4
  • 4
    • 0030087989 scopus 로고    scopus 로고
    • Bone-bonding behavior of plasma-sprayed coatings of Bioglass(R), AW-glass ceramic, and tricalcium phosphate on titanium alloy
    • Kitsugi T., Nakamura T., Oka M., Senaha Y., Goto T., and Shibuya T. Bone-bonding behavior of plasma-sprayed coatings of Bioglass(R), AW-glass ceramic, and tricalcium phosphate on titanium alloy. J Biomed Mater Res 30 2 (1996) 261-269
    • (1996) J Biomed Mater Res , vol.30 , Issue.2 , pp. 261-269
    • Kitsugi, T.1    Nakamura, T.2    Oka, M.3    Senaha, Y.4    Goto, T.5    Shibuya, T.6
  • 6
    • 0036244817 scopus 로고    scopus 로고
    • Plasma-sprayed calcium phosphate particles with high bioactivity and their use in bioactive scaffolds
    • Weng J., Wang M., and Chen J.Y. Plasma-sprayed calcium phosphate particles with high bioactivity and their use in bioactive scaffolds. Biomaterials 23 13 (2002) 2623-2629
    • (2002) Biomaterials , vol.23 , Issue.13 , pp. 2623-2629
    • Weng, J.1    Wang, M.2    Chen, J.Y.3
  • 7
    • 0345533921 scopus 로고    scopus 로고
    • Influence of processing parameters in the plasma spraying of hydroxyapatite/Ti-6Al-4V composite coatings
    • Quek C.H., Khor K.A., and Cheang P. Influence of processing parameters in the plasma spraying of hydroxyapatite/Ti-6Al-4V composite coatings. J Mater Process Technol 90 (1999) 550-555
    • (1999) J Mater Process Technol , vol.90 , pp. 550-555
    • Quek, C.H.1    Khor, K.A.2    Cheang, P.3
  • 8
    • 0031101944 scopus 로고    scopus 로고
    • Thermal spraying of Ti-6Al-4V/hydroxyapatite composites coatings: Powder processing and post-spray treatment
    • Yip C.S., Khor K.A., Loh N.L., and Cheang P. Thermal spraying of Ti-6Al-4V/hydroxyapatite composites coatings: Powder processing and post-spray treatment. J Mater Process Technol 65 1-3 (1997) 73-79
    • (1997) J Mater Process Technol , vol.65 , Issue.1-3 , pp. 73-79
    • Yip, C.S.1    Khor, K.A.2    Loh, N.L.3    Cheang, P.4
  • 9
    • 0037411362 scopus 로고    scopus 로고
    • Effect of spark plasma sintering on the microstructure and in vitro behavior of plasma sprayed HA coatings
    • Yu L.G., Khor K.A., Li H., and Cheang P. Effect of spark plasma sintering on the microstructure and in vitro behavior of plasma sprayed HA coatings. Biomaterials 24 16 (2003) 2695-2705
    • (2003) Biomaterials , vol.24 , Issue.16 , pp. 2695-2705
    • Yu, L.G.1    Khor, K.A.2    Li, H.3    Cheang, P.4
  • 10
    • 0034011721 scopus 로고    scopus 로고
    • Morphology and immersion behavior of plasma-sprayed hydroxyapatite/bioactive glass coatings
    • Ding S.J., Ju C.P., and Lin J.H.C. Morphology and immersion behavior of plasma-sprayed hydroxyapatite/bioactive glass coatings. J Mater Sci-Mater Med 11 3 (2000) 183-190
    • (2000) J Mater Sci-Mater Med , vol.11 , Issue.3 , pp. 183-190
    • Ding, S.J.1    Ju, C.P.2    Lin, J.H.C.3
  • 12
    • 0032035910 scopus 로고    scopus 로고
    • Aaptite formation on surface of ceramics, metals and polymers in body environment
    • Tadashi K. Aaptite formation on surface of ceramics, metals and polymers in body environment. Acta Mater 46 (1998) 2519-2527
    • (1998) Acta Mater , vol.46 , pp. 2519-2527
    • Tadashi, K.1
  • 13
    • 0036569350 scopus 로고    scopus 로고
    • Electrochemical impedance spectroscopy study of the nucleation and growth of apatite on chemically treated pure titanium
    • Wang C.X., and Wang M. Electrochemical impedance spectroscopy study of the nucleation and growth of apatite on chemically treated pure titanium. Mater Lett 54 1 (2002) 30-36
    • (2002) Mater Lett , vol.54 , Issue.1 , pp. 30-36
    • Wang, C.X.1    Wang, M.2
  • 14
    • 0036013935 scopus 로고    scopus 로고
    • Morphological regulation and crystal growth of hydrothermal-electrochemically deposited apatite
    • Ban S., and Hasegawa J. Morphological regulation and crystal growth of hydrothermal-electrochemically deposited apatite. Biomaterials 23 14 (2002) 2965-2972
    • (2002) Biomaterials , vol.23 , Issue.14 , pp. 2965-2972
    • Ban, S.1    Hasegawa, J.2
  • 15
    • 0030298049 scopus 로고    scopus 로고
    • Preparation of bioactive Ti and its alloys via simple chemical surface treatment
    • Kim H.M., Miyaji F., Kokubo T., and Nakamura T. Preparation of bioactive Ti and its alloys via simple chemical surface treatment. J Biomed Mater Res 32 3 (1996) 409-417
    • (1996) J Biomed Mater Res , vol.32 , Issue.3 , pp. 409-417
    • Kim, H.M.1    Miyaji, F.2    Kokubo, T.3    Nakamura, T.4
  • 16
    • 0032127541 scopus 로고    scopus 로고
    • Morphology and microstructure of electrochemically deposited calcium phosphates in a modified simulated body fluid
    • Ban S., and Maruno S. Morphology and microstructure of electrochemically deposited calcium phosphates in a modified simulated body fluid. Biomaterials 19 14 (1998) 1245-1253
    • (1998) Biomaterials , vol.19 , Issue.14 , pp. 1245-1253
    • Ban, S.1    Maruno, S.2
  • 19
    • 0034916246 scopus 로고    scopus 로고
    • Magnetic water treatment for scale prevetion
    • Gabrielli C., Jaouhari R., Maurin G., and Keddam M. Magnetic water treatment for scale prevetion. Water Res 35 13 (2001) 3249-3259
    • (2001) Water Res , vol.35 , Issue.13 , pp. 3249-3259
    • Gabrielli, C.1    Jaouhari, R.2    Maurin, G.3    Keddam, M.4
  • 20
    • 0030087834 scopus 로고    scopus 로고
    • Review paper: Magnetic amelioration of scale formation
    • John S.B., and Simon J.J. Review paper: Magnetic amelioration of scale formation. Water Res 30 2 (1996) 247-260
    • (1996) Water Res , vol.30 , Issue.2 , pp. 247-260
    • John, S.B.1    Simon, J.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.