메뉴 건너뛰기




Volumn 42, Issue 4, 2007, Pages 1711-1717

Uncertainty in indoor air quality and grey system method

Author keywords

Grey system theory; Indoor air quality; Uncertainty

Indexed keywords

AIR CONDITIONING; AIR PURIFICATION; CONTAMINATION; HEATING; HUMIDITY CONTROL; MATHEMATICAL MODELS; VENTILATION;

EID: 33751537152     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2006.01.015     Document Type: Article
Times cited : (46)

References (12)
  • 1
    • 0003517967 scopus 로고
    • Huazhong University of Science and Technology Press, Wuhan
    • Deng J.L. Grey control systems. 2nd ed (1992), Huazhong University of Science and Technology Press, Wuhan
    • (1992) Grey control systems. 2nd ed
    • Deng, J.L.1
  • 2
    • 33751538395 scopus 로고    scopus 로고
    • ASHRAE. ASHRAE Standard 62-2001, Ventilation for acceptable indoor air quality. Atlanta: American Society of Heating, Refrigerating and Air-condition Engineers, Inc.
  • 3
    • 0033165845 scopus 로고    scopus 로고
    • Grey predicting theory and application of energy consumption of building heat-moisture system
    • Wang X., Chen Z., Yang C., and Chen Y. Grey predicting theory and application of energy consumption of building heat-moisture system. Building and Environment 34 4 (1999) 417-420
    • (1999) Building and Environment , vol.34 , Issue.4 , pp. 417-420
    • Wang, X.1    Chen, Z.2    Yang, C.3    Chen, Y.4
  • 4
    • 0036600579 scopus 로고    scopus 로고
    • Building thermal process analysis with grey system method
    • Hu W.B., Hua B., and Yang C.Z. Building thermal process analysis with grey system method. Building and Environment 37 6 (2002) 599-605
    • (2002) Building and Environment , vol.37 , Issue.6 , pp. 599-605
    • Hu, W.B.1    Hua, B.2    Yang, C.Z.3
  • 6
    • 33751515262 scopus 로고    scopus 로고
    • The subject evaluation of indoor air quality for office buildings in Shanghai
    • Shen J.M., Mao J.C., and Cai W. The subject evaluation of indoor air quality for office buildings in Shanghai. Ventilation and Dust control 15 2 (1996) 14-17
    • (1996) Ventilation and Dust control , vol.15 , Issue.2 , pp. 14-17
    • Shen, J.M.1    Mao, J.C.2    Cai, W.3
  • 7
    • 33751515262 scopus 로고    scopus 로고
    • The objective evaluation of indoor air quality for office buildings in Shanghai
    • Shen J.M., Mao J.C., and Sun G.Q. The objective evaluation of indoor air quality for office buildings in Shanghai. Ventilation and Dust control 14 2 (1995) 14-17
    • (1995) Ventilation and Dust control , vol.14 , Issue.2 , pp. 14-17
    • Shen, J.M.1    Mao, J.C.2    Sun, G.Q.3
  • 9
    • 3142523777 scopus 로고
    • A grey model for river water quality and its grey parameters' optimal estimation
    • Zeng G.M., and Ye S.Z. A grey model for river water quality and its grey parameters' optimal estimation. The Journal of Grey System 1 (1989) 53-64
    • (1989) The Journal of Grey System , vol.1 , pp. 53-64
    • Zeng, G.M.1    Ye, S.Z.2
  • 10
    • 33751525626 scopus 로고    scopus 로고
    • Zhu CH. Assessment method of indoor air quality and its application based on grey system theory. Master degree thesis. Hunan University, Changsha, People's Republic of China, 2002.
  • 11
    • 0033684307 scopus 로고    scopus 로고
    • Evaluation of indoor air quality using the decible concept based on carbon dioxide and TVOC
    • Jokl M.V. Evaluation of indoor air quality using the decible concept based on carbon dioxide and TVOC. Building and Environment 35 8 (2000) 677-697
    • (2000) Building and Environment , vol.35 , Issue.8 , pp. 677-697
    • Jokl, M.V.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.