1
-
-
0000008945
-
The use of dehumidifiers in desiccant cooling and dehumidification systems
-
Van Den Bulck E. The use of dehumidifiers in desiccant cooling and dehumidification systems. ASME J Heat Transfer 108 (1986) 684-692
-
(1986)
ASME J Heat Transfer
, vol.108
, pp. 684-692
-
-
Van Den Bulck, E.1
-
2
-
-
0026156925
-
Numerical simulation of a desiccant bed for solar air conditioning applications
-
Farooq S., and Ruthven D.M. Numerical simulation of a desiccant bed for solar air conditioning applications. ASME J Sol Energy Eng 113 (1991) 80-88
-
(1991)
ASME J Sol Energy Eng
, vol.113
, pp. 80-88
-
-
Farooq, S.1
Ruthven, D.M.2
-
3
-
-
0005557973
-
Performance analysis of open-cycle desiccant cooling systems
-
Collier Jr. R.K., Novosel D., and Worek W.M. Performance analysis of open-cycle desiccant cooling systems. ASHRAE Trans 96 (1990) 1262-1268
-
(1990)
ASHRAE Trans
, vol.96
, pp. 1262-1268
-
-
Collier Jr., R.K.1
Novosel, D.2
Worek, W.M.3
-
4
-
-
0021476987
-
Open-cycle desiccant air conditioning as an alternative to vapor compression cooling in residential applications
-
Jurinak J.J., Mitchell J.W., and Beckman W.A. Open-cycle desiccant air conditioning as an alternative to vapor compression cooling in residential applications. ASME J Sol Energy Eng 106 (1984) 252-260
-
(1984)
ASME J Sol Energy Eng
, vol.106
, pp. 252-260
-
-
Jurinak, J.J.1
Mitchell, J.W.2
Beckman, W.A.3
-
5
-
-
0024898938
-
Experiments on silica gel rotary dehumidifier
-
Krishna S.M., and Murthy S.S. Experiments on silica gel rotary dehumidifier. Heat Recovery Syst CHP 9 (1989) 467-473
-
(1989)
Heat Recovery Syst CHP
, vol.9
, pp. 467-473
-
-
Krishna, S.M.1
Murthy, S.S.2
-
6
-
-
0027475182
-
Experimental study of the optimal operation for a honeycomb rotor adsorber operated with thermal swing
-
Kodama A., Goto M., Hirose T., and Kuma T. Experimental study of the optimal operation for a honeycomb rotor adsorber operated with thermal swing. J Chem Eng Jpn 26 (1993) 530-535
-
(1993)
J Chem Eng Jpn
, vol.26
, pp. 530-535
-
-
Kodama, A.1
Goto, M.2
Hirose, T.3
Kuma, T.4
-
7
-
-
0042160709
-
Experimental studies on the dehumidifier and regenerator of a liquid desiccant cooling system
-
Jain S., Dhar P.L., and Kaushik S.C. Experimental studies on the dehumidifier and regenerator of a liquid desiccant cooling system. Appl Therm Eng 20 (2000) 253-267
-
(2000)
Appl Therm Eng
, vol.20
, pp. 253-267
-
-
Jain, S.1
Dhar, P.L.2
Kaushik, S.C.3
-
8
-
-
0029277264
-
Effect of operating conditions on optimal performance of rotary dehumidifiers
-
Zheng W., Worek W.M., and Novosel D. Effect of operating conditions on optimal performance of rotary dehumidifiers. ASME J Energy Resources Technology 117 (1995) 62-66
-
(1995)
ASME J Energy Resources Technology
, vol.117
, pp. 62-66
-
-
Zheng, W.1
Worek, W.M.2
Novosel, D.3
-
9
-
-
0032778092
-
A feasibility study of a solar desiccant air-conditioning system-Part I: Psychrometrics and analysis of the conditioned zone
-
Davanagere B.S., Sherif S.A., and Goswami Y. A feasibility study of a solar desiccant air-conditioning system-Part I: Psychrometrics and analysis of the conditioned zone. Int J Energy Res 23 (1999) 7-21
-
(1999)
Int J Energy Res
, vol.23
, pp. 7-21
-
-
Davanagere, B.S.1
Sherif, S.A.2
Goswami, Y.3
-
10
-
-
0033078503
-
A feasibility study of a solar desiccant air-conditioning system-Part II: Transient simulation and economics
-
Davanagere B.S., Sherif S.A., and Goswami Y. A feasibility study of a solar desiccant air-conditioning system-Part II: Transient simulation and economics. Int J Energy Res 23 (1999) 103-116
-
(1999)
Int J Energy Res
, vol.23
, pp. 103-116
-
-
Davanagere, B.S.1
Sherif, S.A.2
Goswami, Y.3
-
11
-
-
0036629134
-
The potential for solar powered single-stage desiccant cooling in southern Europe
-
Mavroudaki P., Beggs C.B., Sleigh P.A., and Halliday S.P. The potential for solar powered single-stage desiccant cooling in southern Europe. Appl Therm Eng 22 (2002) 1129-1140
-
(2002)
Appl Therm Eng
, vol.22
, pp. 1129-1140
-
-
Mavroudaki, P.1
Beggs, C.B.2
Sleigh, P.A.3
Halliday, S.P.4
-
12
-
-
0036668293
-
The use of solar desiccant cooling in the UK: a feasibility study
-
Halliday S.P., Beggs C.B., and Sleigh P.A. The use of solar desiccant cooling in the UK: a feasibility study. Appl Therm Eng 22 (2002) 1327-1338
-
(2002)
Appl Therm Eng
, vol.22
, pp. 1327-1338
-
-
Halliday, S.P.1
Beggs, C.B.2
Sleigh, P.A.3
-
15
-
-
0030131780
-
The second law analysis of a recirculation cycle desiccant cooling system: cosorption of water vapor and carbon dioxide
-
Shen C.M., and Worek W.M. The second law analysis of a recirculation cycle desiccant cooling system: cosorption of water vapor and carbon dioxide. Atmos Environ 20 (1996) 1429-1435
-
(1996)
Atmos Environ
, vol.20
, pp. 1429-1435
-
-
Shen, C.M.1
Worek, W.M.2
-
16
-
-
0034000283
-
Entropic analysis of adsorption open cycles for air conditioning. Part 1: first and second law analyses
-
Pons M., and Kodama A. Entropic analysis of adsorption open cycles for air conditioning. Part 1: first and second law analyses. Int J Energy Res 24 (2000) 251-262
-
(2000)
Int J Energy Res
, vol.24
, pp. 251-262
-
-
Pons, M.1
Kodama, A.2
-
17
-
-
0034004151
-
Entropic analysis of adsorption open cycles for air conditioning. Part 2: interpretation of experimental data
-
Kodama A., Jin W., Goto M., Hirose T., and Pons M. Entropic analysis of adsorption open cycles for air conditioning. Part 2: interpretation of experimental data. Int J Energy Res 24 (2000) 263-278
-
(2000)
Int J Energy Res
, vol.24
, pp. 263-278
-
-
Kodama, A.1
Jin, W.2
Goto, M.3
Hirose, T.4
Pons, M.5
-
18
-
-
33751399036
-
-
ARI. Standard for desiccant dehumidification components, Standard 940-98, American Air-Conditioning and Refrigeration Institute, Arlington, VA, 1998.
-
-
-
-
19
-
-
33751406003
-
-
Klein SA, Alvarado FL. Engineering equation solver (EES), F-Chart Software. www.fChart.com, 2002.
-
-
-
|