메뉴 건너뛰기




Volumn 32, Issue 6, 2007, Pages 931-946

Effect of ambient conditions on the first and second law performance of an open desiccant cooling process

Author keywords

Air conditioning; Cooling; Desiccant; Refrigeration; Second law analysis

Indexed keywords

ATMOSPHERIC HUMIDITY; COOLING; EVAPORATION; REGENERATORS; THERMAL EFFECTS; VENTILATION;

EID: 33751411067     PISSN: 09601481     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.renene.2006.04.001     Document Type: Article
Times cited : (44)

References (20)
  • 1
    • 0000008945 scopus 로고
    • The use of dehumidifiers in desiccant cooling and dehumidification systems
    • Van Den Bulck E. The use of dehumidifiers in desiccant cooling and dehumidification systems. ASME J Heat Transfer 108 (1986) 684-692
    • (1986) ASME J Heat Transfer , vol.108 , pp. 684-692
    • Van Den Bulck, E.1
  • 2
    • 0026156925 scopus 로고
    • Numerical simulation of a desiccant bed for solar air conditioning applications
    • Farooq S., and Ruthven D.M. Numerical simulation of a desiccant bed for solar air conditioning applications. ASME J Sol Energy Eng 113 (1991) 80-88
    • (1991) ASME J Sol Energy Eng , vol.113 , pp. 80-88
    • Farooq, S.1    Ruthven, D.M.2
  • 3
    • 0005557973 scopus 로고
    • Performance analysis of open-cycle desiccant cooling systems
    • Collier Jr. R.K., Novosel D., and Worek W.M. Performance analysis of open-cycle desiccant cooling systems. ASHRAE Trans 96 (1990) 1262-1268
    • (1990) ASHRAE Trans , vol.96 , pp. 1262-1268
    • Collier Jr., R.K.1    Novosel, D.2    Worek, W.M.3
  • 4
    • 0021476987 scopus 로고
    • Open-cycle desiccant air conditioning as an alternative to vapor compression cooling in residential applications
    • Jurinak J.J., Mitchell J.W., and Beckman W.A. Open-cycle desiccant air conditioning as an alternative to vapor compression cooling in residential applications. ASME J Sol Energy Eng 106 (1984) 252-260
    • (1984) ASME J Sol Energy Eng , vol.106 , pp. 252-260
    • Jurinak, J.J.1    Mitchell, J.W.2    Beckman, W.A.3
  • 5
    • 0024898938 scopus 로고
    • Experiments on silica gel rotary dehumidifier
    • Krishna S.M., and Murthy S.S. Experiments on silica gel rotary dehumidifier. Heat Recovery Syst CHP 9 (1989) 467-473
    • (1989) Heat Recovery Syst CHP , vol.9 , pp. 467-473
    • Krishna, S.M.1    Murthy, S.S.2
  • 6
    • 0027475182 scopus 로고
    • Experimental study of the optimal operation for a honeycomb rotor adsorber operated with thermal swing
    • Kodama A., Goto M., Hirose T., and Kuma T. Experimental study of the optimal operation for a honeycomb rotor adsorber operated with thermal swing. J Chem Eng Jpn 26 (1993) 530-535
    • (1993) J Chem Eng Jpn , vol.26 , pp. 530-535
    • Kodama, A.1    Goto, M.2    Hirose, T.3    Kuma, T.4
  • 7
    • 0042160709 scopus 로고    scopus 로고
    • Experimental studies on the dehumidifier and regenerator of a liquid desiccant cooling system
    • Jain S., Dhar P.L., and Kaushik S.C. Experimental studies on the dehumidifier and regenerator of a liquid desiccant cooling system. Appl Therm Eng 20 (2000) 253-267
    • (2000) Appl Therm Eng , vol.20 , pp. 253-267
    • Jain, S.1    Dhar, P.L.2    Kaushik, S.C.3
  • 8
    • 0029277264 scopus 로고
    • Effect of operating conditions on optimal performance of rotary dehumidifiers
    • Zheng W., Worek W.M., and Novosel D. Effect of operating conditions on optimal performance of rotary dehumidifiers. ASME J Energy Resources Technology 117 (1995) 62-66
    • (1995) ASME J Energy Resources Technology , vol.117 , pp. 62-66
    • Zheng, W.1    Worek, W.M.2    Novosel, D.3
  • 9
    • 0032778092 scopus 로고    scopus 로고
    • A feasibility study of a solar desiccant air-conditioning system-Part I: Psychrometrics and analysis of the conditioned zone
    • Davanagere B.S., Sherif S.A., and Goswami Y. A feasibility study of a solar desiccant air-conditioning system-Part I: Psychrometrics and analysis of the conditioned zone. Int J Energy Res 23 (1999) 7-21
    • (1999) Int J Energy Res , vol.23 , pp. 7-21
    • Davanagere, B.S.1    Sherif, S.A.2    Goswami, Y.3
  • 10
    • 0033078503 scopus 로고    scopus 로고
    • A feasibility study of a solar desiccant air-conditioning system-Part II: Transient simulation and economics
    • Davanagere B.S., Sherif S.A., and Goswami Y. A feasibility study of a solar desiccant air-conditioning system-Part II: Transient simulation and economics. Int J Energy Res 23 (1999) 103-116
    • (1999) Int J Energy Res , vol.23 , pp. 103-116
    • Davanagere, B.S.1    Sherif, S.A.2    Goswami, Y.3
  • 11
    • 0036629134 scopus 로고    scopus 로고
    • The potential for solar powered single-stage desiccant cooling in southern Europe
    • Mavroudaki P., Beggs C.B., Sleigh P.A., and Halliday S.P. The potential for solar powered single-stage desiccant cooling in southern Europe. Appl Therm Eng 22 (2002) 1129-1140
    • (2002) Appl Therm Eng , vol.22 , pp. 1129-1140
    • Mavroudaki, P.1    Beggs, C.B.2    Sleigh, P.A.3    Halliday, S.P.4
  • 12
    • 0036668293 scopus 로고    scopus 로고
    • The use of solar desiccant cooling in the UK: a feasibility study
    • Halliday S.P., Beggs C.B., and Sleigh P.A. The use of solar desiccant cooling in the UK: a feasibility study. Appl Therm Eng 22 (2002) 1327-1338
    • (2002) Appl Therm Eng , vol.22 , pp. 1327-1338
    • Halliday, S.P.1    Beggs, C.B.2    Sleigh, P.A.3
  • 13
    • 0020167437 scopus 로고
    • Second law analysis of desiccant cooling systems
    • Lavan Z., Monnier J.B., and Worek W.M. Second law analysis of desiccant cooling systems. ASME J Sol Energy Eng 104 (1982) 229-236
    • (1982) ASME J Sol Energy Eng , vol.104 , pp. 229-236
    • Lavan, Z.1    Monnier, J.B.2    Worek, W.M.3
  • 15
    • 0030131780 scopus 로고    scopus 로고
    • The second law analysis of a recirculation cycle desiccant cooling system: cosorption of water vapor and carbon dioxide
    • Shen C.M., and Worek W.M. The second law analysis of a recirculation cycle desiccant cooling system: cosorption of water vapor and carbon dioxide. Atmos Environ 20 (1996) 1429-1435
    • (1996) Atmos Environ , vol.20 , pp. 1429-1435
    • Shen, C.M.1    Worek, W.M.2
  • 16
    • 0034000283 scopus 로고    scopus 로고
    • Entropic analysis of adsorption open cycles for air conditioning. Part 1: first and second law analyses
    • Pons M., and Kodama A. Entropic analysis of adsorption open cycles for air conditioning. Part 1: first and second law analyses. Int J Energy Res 24 (2000) 251-262
    • (2000) Int J Energy Res , vol.24 , pp. 251-262
    • Pons, M.1    Kodama, A.2
  • 17
    • 0034004151 scopus 로고    scopus 로고
    • Entropic analysis of adsorption open cycles for air conditioning. Part 2: interpretation of experimental data
    • Kodama A., Jin W., Goto M., Hirose T., and Pons M. Entropic analysis of adsorption open cycles for air conditioning. Part 2: interpretation of experimental data. Int J Energy Res 24 (2000) 263-278
    • (2000) Int J Energy Res , vol.24 , pp. 263-278
    • Kodama, A.1    Jin, W.2    Goto, M.3    Hirose, T.4    Pons, M.5
  • 18
    • 33751399036 scopus 로고    scopus 로고
    • ARI. Standard for desiccant dehumidification components, Standard 940-98, American Air-Conditioning and Refrigeration Institute, Arlington, VA, 1998.
  • 19
    • 33751406003 scopus 로고    scopus 로고
    • Klein SA, Alvarado FL. Engineering equation solver (EES), F-Chart Software. www.fChart.com, 2002.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.