메뉴 건너뛰기




Volumn 2005, Issue , 2005, Pages 1-6

Implementing an advanced simulation tool for comprehensive fault analysis

Author keywords

Alternative transients program; Fault analysis; MATLAB; Modeling; Protective relaying; Simulation

Indexed keywords

ALTERNATIVE TRANSIENTS PROGRAM; FAULT ANALYSIS; MATLAB; PROTECTIVE RELAYING; RELAY MODEL;

EID: 33751375979     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/TDC.2005.1546910     Document Type: Conference Paper
Times cited : (8)

References (14)
  • 1
    • 0039575816 scopus 로고    scopus 로고
    • North American Electric Reliability Council, New Jersey
    • NERC Disturbance Reports, North American Electric Reliability Council, New Jersey, 1996-2001.
    • (1996) NERC Disturbance Reports
  • 2
    • 0004235292 scopus 로고    scopus 로고
    • Natrick, Massachusetts, January
    • The Math Works, Inc.: "Using MATLAB"; (Natrick, Massachusetts, January, 1999.).
    • (1999) Using MATLAB
  • 4
    • 0031125901 scopus 로고    scopus 로고
    • A novel approach for interactive protection system simulation
    • April
    • M. Kezunovic, Q. Chen, "A novel approach for interactive protection system simulation", IEEE Trans. on Power Delivery, Vol.12, No.2, April 1997.
    • (1997) IEEE Trans. on Power Delivery , vol.12 , Issue.2
    • Kezunovic, M.1    Chen, Q.2
  • 5
    • 0030735522 scopus 로고    scopus 로고
    • Creating an electromagnetic transient program in MATLAB: MatEMTP
    • Jan.
    • J. Mahseredjian, F. Alvarado, "Creating an electromagnetic transient program in MATLAB: MatEMTP", IEEE Trans. on Power Delivery, Vol. 12, No. 1, Jan. 1997.
    • (1997) IEEE Trans. on Power Delivery , vol.12 , Issue.1
    • Mahseredjian, J.1    Alvarado, F.2
  • 6
    • 0038617394 scopus 로고    scopus 로고
    • A link between EMTP and MATLAB for user-defined modeling
    • April
    • J. Mahseredjian, G. Benmouyal, etc, "A link between EMTP and MATLAB for user-defined modeling", IEEE Trans. on Power Delivery, Vol.13, No.2, April 1998.
    • (1998) IEEE Trans. on Power Delivery , vol.13 , Issue.2
    • Mahseredjian, J.1    Benmouyal, G.2
  • 7
    • 33746486060 scopus 로고    scopus 로고
    • Design and implementation of scenarios for evaluating and testing distance relays
    • College Station, Texas, Oct.
    • D. Ristanovic, S. Vasilic, M. Kezunovic, "Design and implementation of scenarios for evaluating and testing distance relays," North American Power Symposium - NAPS, College Station, Texas, Oct. 2001.
    • (2001) North American Power Symposium - NAPS
    • Ristanovic, D.1    Vasilic, S.2    Kezunovic, M.3
  • 8
    • 0005685695 scopus 로고
    • Fundamental basis for distance relaying on 3-phase systems
    • Feb.
    • W. A. Lewis and S. Tippet, "Fundamental basis for distance relaying on 3-phase systems," AIEE Trans., vol., 66, pp. 694-708, Feb. 1947.
    • (1947) AIEE Trans. , vol.66 , pp. 694-708
    • Lewis, W.A.1    Tippet, S.2
  • 9
    • 33746477953 scopus 로고    scopus 로고
    • Phase and ground distance relay, directional overcurrent relay
    • SEL-321 Schweitzer Engineering Laboratories Inc., Pullman, WA, Mar.
    • SEL-321 Phase and Ground Distance Relay, Directional Overcurrent Relay, Fault Locator: Instruction Manual, Schweitzer Engineering Laboratories Inc., Pullman, WA, Mar. 1998.
    • (1998) Fault Locator: Instruction Manual
  • 10
    • 0030779306 scopus 로고    scopus 로고
    • Distance relay application testing using a digital simulator
    • January
    • M. Kezunovic, Y.Q. Xia, etc, "Distance Relay Application Testing Using a Digital Simulator," IEEE Transactions on Power Delivery, Vol. 12, No. 1, pp. 72-82, January 1997.
    • (1997) IEEE Transactions on Power Delivery , vol.12 , Issue.1 , pp. 72-82
    • Kezunovic, M.1    Xia, Y.Q.2
  • 11
    • 17744393875 scopus 로고    scopus 로고
    • Fuzzy ART neural network algorithm for classifying the power system faults
    • April
    • S. Vasilic, M. Kezunovic, "Fuzzy ART neural network algorithm for classifying the power system faults," IEEE Trans. on Power Delivery, vol. 20, no. 2, pp.1306-1314, April 2005.
    • (2005) IEEE Trans. on Power Delivery , vol.20 , Issue.2 , pp. 1306-1314
    • Vasilic, S.1    Kezunovic, M.2
  • 12
    • 27144512180 scopus 로고    scopus 로고
    • Coordinating fuzzy ART neural networks to improv transmission line fault detection and classification
    • San Francisco, June
    • Nan Zhang, M. Kezonovic, "Coordinating fuzzy ART neural networks to improv transmission line fault detection and classification," IEEE PES General Meeting, San Francisco, June 2005.
    • (2005) IEEE PES General Meeting
    • Zhang, N.1    Kezonovic, M.2
  • 13
    • 0028426833 scopus 로고
    • An accurate fault location algorithm using synchronized sampling
    • May
    • M. Kezunovic, B. Perunicic, and J. Mrkic, "An Accurate Fault Location Algorithm Using Synchronized Sampling," Electric Power Systems Research Journal, Vol. 29, No. 3, pp. 161-169, May 1994.
    • (1994) Electric Power Systems Research Journal , vol.29 , Issue.3 , pp. 161-169
    • Kezunovic, M.1    Perunicic, B.2    Mrkic, J.3
  • 14
    • 51549112506 scopus 로고    scopus 로고
    • A study of synchronized sampling based fault location algorithm performance under power swing and out-of-step condition
    • St. Petersburg, Russia, June
    • Nan Zhang, M. Kezunovic, "A study of synchronized sampling based fault location algorithm performance under power swing and out-of-step condition," St. Petersburg PowerTech' 05, St. Petersburg, Russia, June 2005
    • (2005) St. Petersburg PowerTech' 05
    • Zhang, N.1    Kezunovic, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.