메뉴 건너뛰기




Volumn 80, Issue 12, 2006, Pages 1517-1539

Optimal sizing of array and inverter for grid-connected photovoltaic systems

Author keywords

Grid connected photovoltaics; Orientation and inclination; Performance ratio; PV inverter sizing ratio; TRNSYS

Indexed keywords

CORRELATION METHODS; COSTS; ELECTRIC INVERTERS; OPTIMIZATION; SOLAR CELL ARRAYS;

EID: 33751306290     PISSN: 0038092X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.solener.2006.01.006     Document Type: Article
Times cited : (152)

References (21)
  • 1
    • 29144475387 scopus 로고    scopus 로고
    • Inverter sizing of grid-connected photovoltaic systems in the light of local solar resource distribution characteristics and temperature
    • Burger B., and Rüther R. Inverter sizing of grid-connected photovoltaic systems in the light of local solar resource distribution characteristics and temperature. Solar Energy 80 (2006) 32-45
    • (2006) Solar Energy , vol.80 , pp. 32-45
    • Burger, B.1    Rüther, R.2
  • 2
    • 33751310029 scopus 로고    scopus 로고
    • Coppye, W., Maranda, W., Nir, Y., De Gheselle, L., Nijs, J., 1995. Detailed comparison of the inverter operation of two grid-connected PV demonstration systems in Belgium. In: 13th European Photovoltaic Solar Energy Conference, Nice, France, pp. 1881-1884.
  • 3
    • 33751314202 scopus 로고    scopus 로고
    • Decker, B., Jahn, U., Rindelhardt, U., Vaaβen, W., 1992. The German 1000-roof-photovoltaic-programme: system design and energy balance. In: 11th European Photovoltaic Solar Energy Conference, Montreux, Switzerland, pp. 1497-1500.
  • 4
    • 33751341714 scopus 로고    scopus 로고
    • Jantsch, M., Schmidt, H., Schmid, J., 1992. Results of the concerted action on power conditioning and control. In: 11th Photovoltaic Solar Energy Conference, Montreux, Switzerland, pp. 1589-1593.
  • 5
    • 33751312391 scopus 로고    scopus 로고
    • Keller, L., Affolter, P., 1992. Optimizing the panel area of a photovoltaic system in relation to the static inverter. In: 11th European Photovoltaic Solar Energy Conference, Montreux, Switzerland, pp. 1159-1162.
  • 6
    • 0029341681 scopus 로고
    • Optimizing the panel area of a photovoltaic system in relation to the static inverter-practical results
    • Keller L., and Affolter P. Optimizing the panel area of a photovoltaic system in relation to the static inverter-practical results. Solar Energy 55 (1995) 1-7
    • (1995) Solar Energy , vol.55 , pp. 1-7
    • Keller, L.1    Affolter, P.2
  • 7
    • 0028690868 scopus 로고    scopus 로고
    • Kil, A.J., Van der Weiden, T.C.J., 1994. Performance of modular grid connected PV systems with undersized inverters in Portugal and the Netherlands. In: IEEE Photovoltaic Specialists Conference, Waikoloa, Hawaii, USA, pp. 1028-1031.
  • 8
    • 33751327434 scopus 로고    scopus 로고
    • Klein, S.A. et al., 2000. TRNSYS 15, A transient simulation program. Solar Energy Laboratory, University of Wisconsin Madison, Wisconsin, USA.
  • 9
    • 0011384098 scopus 로고
    • Daily insolation on surfaces tilted towards the equator
    • Liu B.Y.H., and Jordan R.C. Daily insolation on surfaces tilted towards the equator. Trans ASHARE 67 (1962) 526-541
    • (1962) Trans ASHARE , vol.67 , pp. 526-541
    • Liu, B.Y.H.1    Jordan, R.C.2
  • 10
    • 33751341458 scopus 로고    scopus 로고
    • Louche, A., Notton, G., Poggi, P., Peri, G., 1994. Global approach for an optimal grid connected PV system sizing. In: 12th European Photovoltaic Solar Energy Conference, Amsterdam, The Netherlands, pp. 1638-1641.
  • 11
    • 33751319813 scopus 로고    scopus 로고
    • Macagnan, M.H., Lorenzo, E., 1992. On the optimal size of inverters for grid connected PV systems. In: 11th European Photovoltaic Solar Energy Conference, Montreux, Switzerland, pp. 1167-1170.
  • 12
    • 0032140202 scopus 로고    scopus 로고
    • Optimization of the master-slave inverter system for grid-connected photovoltaic plants
    • Marańda W., Mey G.D., and Vos A.D. Optimization of the master-slave inverter system for grid-connected photovoltaic plants. Energy Conversion and Management 39 (1998) 1239-1246
    • (1998) Energy Conversion and Management , vol.39 , pp. 1239-1246
    • Marańda, W.1    Mey, G.D.2    Vos, A.D.3
  • 13
    • 12444261688 scopus 로고    scopus 로고
    • Long-term validated simulation of a building integrated photovoltaic system
    • Mondol J.D., Yohanis Y.G., Smyth M., and Norton B. Long-term validated simulation of a building integrated photovoltaic system. Solar Energy 78 (2005) 163-176
    • (2005) Solar Energy , vol.78 , pp. 163-176
    • Mondol, J.D.1    Yohanis, Y.G.2    Smyth, M.3    Norton, B.4
  • 14
    • 0032156899 scopus 로고    scopus 로고
    • An approach to the selection of the inverter for architecturally integrated photovoltaic grid-connected systems
    • Nofuentes G., and Almonacid G. An approach to the selection of the inverter for architecturally integrated photovoltaic grid-connected systems. Renewable Energy 15 (1998) 487-490
    • (1998) Renewable Energy , vol.15 , pp. 487-490
    • Nofuentes, G.1    Almonacid, G.2
  • 15
    • 0033364840 scopus 로고    scopus 로고
    • Design tools for the electrical configuration of architecturally integrated PV in buildings
    • Nofuentes G., and Almonacid G. Design tools for the electrical configuration of architecturally integrated PV in buildings. Progress in Photovoltaics: Research and Applications 7 (1999) 475-488
    • (1999) Progress in Photovoltaics: Research and Applications , vol.7 , pp. 475-488
    • Nofuentes, G.1    Almonacid, G.2
  • 17
    • 0028761527 scopus 로고
    • Optimal sizing of a grid-connected PV systems for different climates and array orientations: a simulation study
    • Peippo K., and Lund P.D. Optimal sizing of a grid-connected PV systems for different climates and array orientations: a simulation study. Solar Energy Materials and Solar Cells 35 (1994) 445-451
    • (1994) Solar Energy Materials and Solar Cells , vol.35 , pp. 445-451
    • Peippo, K.1    Lund, P.D.2
  • 18
    • 0027986366 scopus 로고
    • Optimal sizing of solar array and inverter in grid-connected photovoltaic systems
    • Peippo K., and Lund P.D. Optimal sizing of solar array and inverter in grid-connected photovoltaic systems. Solar Energy Materials and Solar Cells 32 (1994) 95-114
    • (1994) Solar Energy Materials and Solar Cells , vol.32 , pp. 95-114
    • Peippo, K.1    Lund, P.D.2
  • 19
    • 0019652379 scopus 로고    scopus 로고
    • Rasmussen, N.E., Branz, H.M., 1981. The dependence of delivered energy on power conditioner electrical characteristics for utility-interactive PV systems. In: 15th IEEE Photovoltaic Specialists Conference, Kissimmee, Florida, USA, pp. 614-620.
  • 20
    • 33751317919 scopus 로고    scopus 로고
    • Rieß, H., Sprau, P., 1992. Design considerations for the PV generator/inverter matching in grid connected systems. In: 11th European Photovoltaic Solar Energy Conference, Montreux, Switzerland, pp. 1377-1378.
  • 21
    • 33751330544 scopus 로고    scopus 로고
    • Schalkwijk, Van M., Kil, A.J., Weiden, Van der T.C.J., Paes, P.S., 1997. Undersizing of inverters: modelling and monitoring results of 15 PV/Inverter units in Portugal and the Netherlands. In: 14th European Photovoltaic Solar Energy Conference, Barcelona, Spain, pp. 2229-2232.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.