메뉴 건너뛰기




Volumn 42, Issue 3, 2007, Pages 1089-1098

An investigation of air inlet types in mixing ventilation

Author keywords

Ceiling diffuser air inlet; Contaminant concentration; Efficient room configuration; Mixing ventilation; Real time monitoring data; Wall jet air inlet

Indexed keywords

CEILINGS; DIFFUSERS (FLUID); FLOW PATTERNS; INTAKE SYSTEMS; JETS;

EID: 33751304473     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2005.11.006     Document Type: Article
Times cited : (27)

References (18)
  • 1
    • 0010213876 scopus 로고    scopus 로고
    • Dispersal of exhaled air and personal exposure in displacement ventilated rooms
    • Bjorn E., and Nielsen P.V. Dispersal of exhaled air and personal exposure in displacement ventilated rooms. Indoor Air 12 (2002) 147-164
    • (2002) Indoor Air , vol.12 , pp. 147-164
    • Bjorn, E.1    Nielsen, P.V.2
  • 2
    • 0000582130 scopus 로고    scopus 로고
    • Personal exposure in displacement ventilated rooms
    • Brohus H., and Nielsen P.V. Personal exposure in displacement ventilated rooms. Indoor Air 6 (1996) 157-167
    • (1996) Indoor Air , vol.6 , pp. 157-167
    • Brohus, H.1    Nielsen, P.V.2
  • 3
    • 33751268918 scopus 로고    scopus 로고
    • Bjorn E, Nielsen PV. CFD simulations of contaminant transport between two breathing persons. In: Proceedings of roomvent 1998, Stockholm, Sweden, vol. 2, p. 133-40.
  • 5
    • 3242805973 scopus 로고    scopus 로고
    • Pollutant dispersion in a large indoor space: Part 1-scaled experiments using a water-filled model with occupants and furniture
    • Thatcher T.L., Wilson D.J., Wood E.E., Craig M.J., and Sextro R.G. Pollutant dispersion in a large indoor space: Part 1-scaled experiments using a water-filled model with occupants and furniture. Indoor Air 14 (2004) 258-271
    • (2004) Indoor Air , vol.14 , pp. 258-271
    • Thatcher, T.L.1    Wilson, D.J.2    Wood, E.E.3    Craig, M.J.4    Sextro, R.G.5
  • 6
    • 33751287167 scopus 로고    scopus 로고
    • Bjorn E, Mattsson M, Sandberg M, Nielsen PV. Displacement ventilation-effects of movement and exhalation. In: Proceedings of healthy buildings '96, fifth international conference on healthy buildings, 27 Sept-3 Oct, Washington DC, USA, vol. 2, p. 163-8.
  • 7
    • 33751289417 scopus 로고    scopus 로고
    • Mattsson M, Sandberg M. Displacement ventilation-influence of physical activity. In: Proceedings of roomvent '94, fourth international conference on air distribution in rooms, Kracow, Poland, vol. 2, p. 77-92.
  • 8
    • 33751270178 scopus 로고    scopus 로고
    • Mattsson M, Bjorn E, Sandberg M, Nielsen PV. Simulating people moving in displacement ventilated rooms. In: Wood JE, Grimsrud DT, Boschi N, editors. Proceedings of healthy buildings '97, fifth international conference on healthy buildings, Washington, DC, vol. 1, p. 495-500.
  • 10
    • 0036338078 scopus 로고    scopus 로고
    • Performance of deterministic workplace exposure assessment models for various contaminant sources, air inlet, and exhaust locations
    • Feigley C.E., Bennett J.S., Khan J., and Lee E. Performance of deterministic workplace exposure assessment models for various contaminant sources, air inlet, and exhaust locations. American Industrial Hygiene Association Journal 63 (2002) 402-412
    • (2002) American Industrial Hygiene Association Journal , vol.63 , pp. 402-412
    • Feigley, C.E.1    Bennett, J.S.2    Khan, J.3    Lee, E.4
  • 11
    • 0033742745 scopus 로고    scopus 로고
    • Numerical simulation of two-dimensional room air flow with and without buoyancy
    • Sinha S.L., Arora R.C., and Roy S. Numerical simulation of two-dimensional room air flow with and without buoyancy. Energy and Buildings 32 (2000) 121-129
    • (2000) Energy and Buildings , vol.32 , pp. 121-129
    • Sinha, S.L.1    Arora, R.C.2    Roy, S.3
  • 12
    • 33644672368 scopus 로고    scopus 로고
    • Khan JA, Feigley CE, Lee E, Ahmed MR, Tamanna S. Effects of inlet and exhaust locations and emitted gas density on indoor air contaminant concentrations. Building and Environment, in press, doi:10.1016/j.buildenv.2005.04.002.
  • 14
    • 0003440773 scopus 로고
    • E&FN Spon, London ISBN 0419 156909 [Chapter 6]
    • Awbi H.B. Ventilation of buildings (1991), E&FN Spon, London ISBN 0419 156909 [Chapter 6]
    • (1991) Ventilation of buildings
    • Awbi, H.B.1
  • 16
    • 0036832826 scopus 로고    scopus 로고
    • An investigation of air inlet velocity in simulating the dispersion of indoor contaminants via computational fluid dynamics
    • Lee E., Feigley C.E., and Khan J. An investigation of air inlet velocity in simulating the dispersion of indoor contaminants via computational fluid dynamics. Annals of Occupational Hygiene 46 8 (2002) 701-712
    • (2002) Annals of Occupational Hygiene , vol.46 , Issue.8 , pp. 701-712
    • Lee, E.1    Feigley, C.E.2    Khan, J.3
  • 17
    • 0035501647 scopus 로고    scopus 로고
    • Effect of ventilation pattern on room air and contaminant distribution
    • Chung K.C., and Hsu S.P. Effect of ventilation pattern on room air and contaminant distribution. Building and Environment 36 (2001) 989-998
    • (2001) Building and Environment , vol.36 , pp. 989-998
    • Chung, K.C.1    Hsu, S.P.2
  • 18
    • 33751304207 scopus 로고    scopus 로고
    • Lee E. An investigation of physical factors for estimating exposure to airborne contaminants. PhD dissertation, Department of Environmental Health Sciences, University of South Carolina, Columbia, SC 29208.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.