메뉴 건너뛰기




Volumn 39, Issue 16, 2006, Pages 3071-3075

The development and validation of a charge-coupled device laser reflectance system to measure the complex cross-sectional shape and area of soft tissues

Author keywords

Cross sectional area; Image reconstruction; Ligament; Non contact measurement; Tendon

Indexed keywords

CHARGE COUPLED DEVICES; IMAGE RECONSTRUCTION; LASER APPLICATIONS; LIGAMENTS; TENDONS; TISSUE;

EID: 33751243000     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2005.10.029     Document Type: Article
Times cited : (34)

References (23)
  • 1
    • 0018565978 scopus 로고
    • Pressure dependence of the area micrometer method in evaluation of cruciate ligament cross-section
    • Allard P., Thiry P.S., Bourgault A., and Drouin G. Pressure dependence of the area micrometer method in evaluation of cruciate ligament cross-section. Journal of Biomedical Engineering 1 4 (1979) 265-267
    • (1979) Journal of Biomedical Engineering , vol.1 , Issue.4 , pp. 265-267
    • Allard, P.1    Thiry, P.S.2    Bourgault, A.3    Drouin, G.4
  • 2
    • 0021636517 scopus 로고
    • Effects of structure and strain measurement technique on the material properties of young human tendons and fascia
    • Butler D.L., Grood E.S., Noyes F.R., Zernicke R.F., and Brackett K. Effects of structure and strain measurement technique on the material properties of young human tendons and fascia. Journal of Biomechanics 17 8 (1984) 579-596
    • (1984) Journal of Biomechanics , vol.17 , Issue.8 , pp. 579-596
    • Butler, D.L.1    Grood, E.S.2    Noyes, F.R.3    Zernicke, R.F.4    Brackett, K.5
  • 3
    • 33751214557 scopus 로고    scopus 로고
    • Chan, S.S., 1995. The development and evaluation of a laser reflectance system to determine the complex cross-sectional shape and area of soft tissues. M.S. Thesis. University of Pittsburgh Press, Pittsburgh.
  • 4
    • 33751253802 scopus 로고    scopus 로고
    • Chan, S.S., Livesay, G.A., Woo, S.L.-Y., 1996. A new system to accurately determine the cross-sectional shape and area of soft tissues. In: Proceedings of the 42nd Annual Meeting. Orthopaedic Research Society, February 19-22, p. 373.
  • 5
    • 84981824675 scopus 로고
    • The tensile strength of human tendons
    • Conkrite A.E. The tensile strength of human tendons. The Anatomical Record 64 (1936) 173-185
    • (1936) The Anatomical Record , vol.64 , pp. 173-185
    • Conkrite, A.E.1
  • 6
    • 0001453963 scopus 로고
    • Cross-sectional area measurements for tendon specimens: a comparison of several methods
    • Ellis D.G. Cross-sectional area measurements for tendon specimens: a comparison of several methods. Journal of Biomechanics 2 (1969) 175-186
    • (1969) Journal of Biomechanics , vol.2 , pp. 175-186
    • Ellis, D.G.1
  • 7
    • 12344281141 scopus 로고    scopus 로고
    • Cross sectional area measurement of tendon and ligament in vitro: a simple, rapid, non-destructive technique
    • Goodship A.E., and Birch H.L. Cross sectional area measurement of tendon and ligament in vitro: a simple, rapid, non-destructive technique. Journal of Biomechanics 38 3 (2005) 605-608
    • (2005) Journal of Biomechanics , vol.38 , Issue.3 , pp. 605-608
    • Goodship, A.E.1    Birch, H.L.2
  • 8
    • 0000951364 scopus 로고
    • Tensile strength and elasticity tests on human fascia lata
    • Gratz C.M. Tensile strength and elasticity tests on human fascia lata. Journal of Bone and Joint Surgery 13 (1931) 334-340
    • (1931) Journal of Bone and Joint Surgery , vol.13 , pp. 334-340
    • Gratz, C.M.1
  • 10
    • 12344288319 scopus 로고    scopus 로고
    • An alternative method of anthropometry of anterior cruciate ligament through 3-D digital image reconstruction
    • Hashemi J., Chandrashekar N., Cowden C., and Slauterbeck J. An alternative method of anthropometry of anterior cruciate ligament through 3-D digital image reconstruction. Journal of Biomechanics 38 3 (2005) 551-555
    • (2005) Journal of Biomechanics , vol.38 , Issue.3 , pp. 551-555
    • Hashemi, J.1    Chandrashekar, N.2    Cowden, C.3    Slauterbeck, J.4
  • 11
    • 0000321041 scopus 로고
    • Rheological properties of canine anterior cruciate ligaments
    • Haut R.C., and Little R.W. Rheological properties of canine anterior cruciate ligaments. Journal of Biomechanics 2 (1969) 289-298
    • (1969) Journal of Biomechanics , vol.2 , pp. 289-298
    • Haut, R.C.1    Little, R.W.2
  • 12
    • 0032100111 scopus 로고    scopus 로고
    • A high-accuracy three-dimensional coordinate digitizing system for reconstructing the geometry of diarthrodial joints
    • Haut T.L., Hull M.L., and Howell S.M. A high-accuracy three-dimensional coordinate digitizing system for reconstructing the geometry of diarthrodial joints. Journal of Biomechanics 31 6 (1998) 571-577
    • (1998) Journal of Biomechanics , vol.31 , Issue.6 , pp. 571-577
    • Haut, T.L.1    Hull, M.L.2    Howell, S.M.3
  • 13
    • 0023522201 scopus 로고
    • Measurements of cross-sectional area of collagen structures (knee ligaments) by means of an optical method
    • Iaconis F., Steindler R., and Marinozzi G. Measurements of cross-sectional area of collagen structures (knee ligaments) by means of an optical method. Journal of Biomechanics 20 10 (1987) 1003-1010
    • (1987) Journal of Biomechanics , vol.20 , Issue.10 , pp. 1003-1010
    • Iaconis, F.1    Steindler, R.2    Marinozzi, G.3
  • 14
    • 0024017397 scopus 로고
    • A new method for determining cross-sectional shape and area of soft tissues
    • Lee T.Q., and Woo S.L.-Y. A new method for determining cross-sectional shape and area of soft tissues. Journal of Biomechanical Engineering 110 2 (1988) 110-114
    • (1988) Journal of Biomechanical Engineering , vol.110 , Issue.2 , pp. 110-114
    • Lee, T.Q.1    Woo, S.L.-Y.2
  • 15
    • 33751240123 scopus 로고    scopus 로고
    • Njus, G.O., Njus, N.M., 1986. A noncontact method for determining cross-sectional area of soft tissues. In: 32nd Annual Meeting. Orthopaedic Research Society, p. 126.
  • 16
    • 0036238648 scopus 로고    scopus 로고
    • A method of in vitro measurement of the cross-sectional area of soft tissues, using ultrasonography
    • Noguchi M., Kitaura T., Ikoma K., and Kusaka Y. A method of in vitro measurement of the cross-sectional area of soft tissues, using ultrasonography. Journal of Orthopaedic Science 7 2 (2002) 247-251
    • (2002) Journal of Orthopaedic Science , vol.7 , Issue.2 , pp. 247-251
    • Noguchi, M.1    Kitaura, T.2    Ikoma, K.3    Kusaka, Y.4
  • 18
    • 0024017408 scopus 로고
    • A new method of measuring the cross-sectional area of connective tissue structures
    • Shrive N.G., Lam T.C., Damson E., and Frank C.B. A new method of measuring the cross-sectional area of connective tissue structures. Journal of Biomechanical Engineering 110 2 (1988) 104-109
    • (1988) Journal of Biomechanical Engineering , vol.110 , Issue.2 , pp. 104-109
    • Shrive, N.G.1    Lam, T.C.2    Damson, E.3    Frank, C.B.4
  • 20
    • 0017042512 scopus 로고
    • Measurements of nonhomogeneous, directional mechanical properties of articular cartilage in tension
    • Woo S.L.-Y., Akeson W.H., and Jemmott G.F. Measurements of nonhomogeneous, directional mechanical properties of articular cartilage in tension. Journal of Biomechanics 9 12 (1976) 785-791
    • (1976) Journal of Biomechanics , vol.9 , Issue.12 , pp. 785-791
    • Woo, S.L.-Y.1    Akeson, W.H.2    Jemmott, G.F.3
  • 21
    • 0018876157 scopus 로고
    • The biomechanical and biochemical properties of swine tendons-long term effects of exercise on the digital extensors
    • Woo S.L.-Y., Ritter M.A., Amiel D., Sanders T.M., Gomez M.A., Kuei S.C., et al. The biomechanical and biochemical properties of swine tendons-long term effects of exercise on the digital extensors. Connective Tissue Research 7 3 (1980) 177-183
    • (1980) Connective Tissue Research , vol.7 , Issue.3 , pp. 177-183
    • Woo, S.L.-Y.1    Ritter, M.A.2    Amiel, D.3    Sanders, T.M.4    Gomez, M.A.5    Kuei, S.C.6
  • 22
    • 0025689366 scopus 로고
    • The use of a laser micrometer system to determine the cross-sectional shape and area of ligaments: a comparative study with two existing methods
    • Woo S.L.-Y., Danto M.I., Ohland K.J., Lee T.Q., and Newton P.O. The use of a laser micrometer system to determine the cross-sectional shape and area of ligaments: a comparative study with two existing methods. Journal of Biomechanical Engineering 112 4 (1990) 426-431
    • (1990) Journal of Biomechanical Engineering , vol.112 , Issue.4 , pp. 426-431
    • Woo, S.L.-Y.1    Danto, M.I.2    Ohland, K.J.3    Lee, T.Q.4    Newton, P.O.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.