메뉴 건너뛰기




Volumn 30, Issue 8, 2006, Pages 469-477

Automatic arm removal in PET and CT images for deformable registration

Author keywords

Arm removal; Deformable image matching; Lung cancer management; Multimodality image registration; PET CT image fusion; Torso segmentation

Indexed keywords

COMPUTERIZED TOMOGRAPHY; DIAGNOSIS; IMAGE ANALYSIS; POSITRON EMISSION TOMOGRAPHY; TUMORS;

EID: 33751239446     PISSN: 08956111     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.compmedimag.2006.09.013     Document Type: Article
Times cited : (6)

References (14)
  • 2
    • 0033201364 scopus 로고    scopus 로고
    • Automatic 3-D segmentation of internal structures of the head in MR images using a combination of similarity and free-form transformations. Part I: Methodology and validation on normal subjects
    • Dawant B.M., Hartmann S.L., Thirion J.-P., Maes F., Vandermeulen D., and Demaerel P. Automatic 3-D segmentation of internal structures of the head in MR images using a combination of similarity and free-form transformations. Part I: Methodology and validation on normal subjects. IEEE Trans Med Imaging 18 10 (1999) 909-916
    • (1999) IEEE Trans Med Imaging , vol.18 , Issue.10 , pp. 909-916
    • Dawant, B.M.1    Hartmann, S.L.2    Thirion, J.-P.3    Maes, F.4    Vandermeulen, D.5    Demaerel, P.6
  • 7
    • 33751202392 scopus 로고    scopus 로고
    • Mattes D. Automatic multimodality image registration with deformations. Master thesis. Department of Electrical Engineering, University of Washington, 2000.
  • 9
    • 0018306059 scopus 로고
    • A threshold selection method from gray-level histograms
    • Otsu N. A threshold selection method from gray-level histograms. IEEE Trans Syst Man Cybern SMC-9 1 (1979) 62-66
    • (1979) IEEE Trans Syst Man Cybern , vol.SMC-9 , Issue.1 , pp. 62-66
    • Otsu, N.1
  • 11
    • 0031211971 scopus 로고    scopus 로고
    • Utilization of 3-D elastic transformation in the registration of chest X-ray CT and whole body PET
    • Tai Y., Lin K.P., Hoh C.K., Huang S.C.H., and Hoffman E.J. Utilization of 3-D elastic transformation in the registration of chest X-ray CT and whole body PET. IEEE Trans Nucl Sci 44 4 (1997) 1606-1612
    • (1997) IEEE Trans Nucl Sci , vol.44 , Issue.4 , pp. 1606-1612
    • Tai, Y.1    Lin, K.P.2    Hoh, C.K.3    Huang, S.C.H.4    Hoffman, E.J.5
  • 12
    • 0032153006 scopus 로고    scopus 로고
    • Image matching as a diffusion process: an analogy with Maxwell's demons
    • Thirion J.P. Image matching as a diffusion process: an analogy with Maxwell's demons. Med Image Anal 2 3 (1998) 243-260
    • (1998) Med Image Anal , vol.2 , Issue.3 , pp. 243-260
    • Thirion, J.P.1
  • 14
    • 13444262162 scopus 로고    scopus 로고
    • Open source software for medical image processing and visualization
    • Yoo T.S., and Ackerman M.J. Open source software for medical image processing and visualization. Commun ACM 48 2 (2005) 55-59
    • (2005) Commun ACM , vol.48 , Issue.2 , pp. 55-59
    • Yoo, T.S.1    Ackerman, M.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.