-
1
-
-
0030191615
-
Electrothermal atomic absorption spectrometry using an improved solid sampling system for the analysis of high purity tantalum powders
-
Friese K.-Ch., Krivan V., and Schuierer O. Electrothermal atomic absorption spectrometry using an improved solid sampling system for the analysis of high purity tantalum powders. Spectrochim. Acta Part B 51 (1996) 1223-1233
-
(1996)
Spectrochim. Acta Part B
, vol.51
, pp. 1223-1233
-
-
Friese, K.-Ch.1
Krivan, V.2
Schuierer, O.3
-
2
-
-
0032490409
-
A solid sampling system for a transversely heated graphite furnace and its application to the trace element analysis of high-purity tantalum powders by atomic absorption spectrometry
-
Friese K.-Ch., and Krivan V. A solid sampling system for a transversely heated graphite furnace and its application to the trace element analysis of high-purity tantalum powders by atomic absorption spectrometry. Spectrochim. Acta Part B 53 (1998) 1069-1078
-
(1998)
Spectrochim. Acta Part B
, vol.53
, pp. 1069-1078
-
-
Friese, K.-Ch.1
Krivan, V.2
-
3
-
-
0000904352
-
Determination of trace impurities in high purity tungsten by direct solid sampling electrothermal atomic absorption spectrometry using transversely heated graphite tube
-
Hornung M., and Krivan V. Determination of trace impurities in high purity tungsten by direct solid sampling electrothermal atomic absorption spectrometry using transversely heated graphite tube. Anal. Chem. 70 (1998) 3444-3451
-
(1998)
Anal. Chem.
, vol.70
, pp. 3444-3451
-
-
Hornung, M.1
Krivan, V.2
-
4
-
-
17444406293
-
Direct analysis of pieces of high purity titanium by solid sampling electrothermal atomic absorption spectrometry
-
Krivan V., and Huang M.D. Direct analysis of pieces of high purity titanium by solid sampling electrothermal atomic absorption spectrometry. Anal. Chem. 70 (1998) 5312-5321
-
(1998)
Anal. Chem.
, vol.70
, pp. 5312-5321
-
-
Krivan, V.1
Huang, M.D.2
-
5
-
-
0032592709
-
Solid sampling electrothermal atomic absorption spectrometry for analysis of high-purity tungsten trioxide and high-purity tungsten blue oxide
-
Hornung M., and Krivan V. Solid sampling electrothermal atomic absorption spectrometry for analysis of high-purity tungsten trioxide and high-purity tungsten blue oxide. Spectrochim. Acta Part B 54 (1999) 1177-1191
-
(1999)
Spectrochim. Acta Part B
, vol.54
, pp. 1177-1191
-
-
Hornung, M.1
Krivan, V.2
-
6
-
-
0038379695
-
Direct solid sampling electrothermal atomic absorption spectrometry for the analysis of high-purity niobium pentaoxide
-
Huang M.D., and Krivan V. Direct solid sampling electrothermal atomic absorption spectrometry for the analysis of high-purity niobium pentaoxide. Fresenius' J. Anal. Chem. 368 (2000) 227-234
-
(2000)
Fresenius' J. Anal. Chem.
, vol.368
, pp. 227-234
-
-
Huang, M.D.1
Krivan, V.2
-
7
-
-
0034762361
-
Analysis of high purity graphite and silicon carbide by direct solid sampling electrothermal atomic absorption spectrometry
-
Schäffer U., and Krivan V. Analysis of high purity graphite and silicon carbide by direct solid sampling electrothermal atomic absorption spectrometry. Fresenius' J. Anal. Chem. 371 (2001) 859-866
-
(2001)
Fresenius' J. Anal. Chem.
, vol.371
, pp. 859-866
-
-
Schäffer, U.1
Krivan, V.2
-
8
-
-
23944434651
-
A direct solid sampling electrothermal atomic absorption spectrometric method for determination of trace elements in zirconium dioxide
-
Krivan V., and Janickova P. A direct solid sampling electrothermal atomic absorption spectrometric method for determination of trace elements in zirconium dioxide. Anal. Bioanal. Chem. 382 (2005) 1949-1957
-
(2005)
Anal. Bioanal. Chem.
, vol.382
, pp. 1949-1957
-
-
Krivan, V.1
Janickova, P.2
-
9
-
-
50549160582
-
The analytical use of atomic absorption spectra
-
L'vov B.V. The analytical use of atomic absorption spectra. Spectrochim. Acta Part B 17 (1960) 761-770
-
(1960)
Spectrochim. Acta Part B
, vol.17
, pp. 761-770
-
-
L'vov, B.V.1
-
10
-
-
0001126242
-
A new furnace design for constant temperature electrothermal atomic absorption spectrometry
-
Frech W., and Jonsson S. A new furnace design for constant temperature electrothermal atomic absorption spectrometry. Spectrochim. Acta Part B 37 (1982) 1021-1028
-
(1982)
Spectrochim. Acta Part B
, vol.37
, pp. 1021-1028
-
-
Frech, W.1
Jonsson, S.2
-
11
-
-
0342355386
-
Simultaneous multielement analysis by continuum source atomic absorption spectrometry with a spatially and temporally isothermal graphite furnace
-
Lundberg E., Frech W., and Harnly J. Simultaneous multielement analysis by continuum source atomic absorption spectrometry with a spatially and temporally isothermal graphite furnace. J. Anal. At. Spectrom. 3 (1988) 1115-1119
-
(1988)
J. Anal. At. Spectrom.
, vol.3
, pp. 1115-1119
-
-
Lundberg, E.1
Frech, W.2
Harnly, J.3
-
12
-
-
0000895341
-
Identification and effect of pre-atomization losses on the determination of aluminium by graphite furnace atomic absorption spectrometry
-
Redfield D.A., and Frech W. Identification and effect of pre-atomization losses on the determination of aluminium by graphite furnace atomic absorption spectrometry. J. Anal. At. Spectrom. 4 (1989) 685-690
-
(1989)
J. Anal. At. Spectrom.
, vol.4
, pp. 685-690
-
-
Redfield, D.A.1
Frech, W.2
-
13
-
-
0025684316
-
Temperature dependence of atomization efficiencies in graphite furnaces
-
Frech W., and Baxter D.C. Temperature dependence of atomization efficiencies in graphite furnaces. Spectrochim. Acta Part B 45 (1990) 867-886
-
(1990)
Spectrochim. Acta Part B
, vol.45
, pp. 867-886
-
-
Frech, W.1
Baxter, D.C.2
-
14
-
-
0025128161
-
On the direct analysis of solid samples by graphite furnace atomic absorption spectrometry
-
Baxter D.C., and Frech W. On the direct analysis of solid samples by graphite furnace atomic absorption spectrometry. Fresenius' J. Anal. Chem. 337 (1990) 253-263
-
(1990)
Fresenius' J. Anal. Chem.
, vol.337
, pp. 253-263
-
-
Baxter, D.C.1
Frech, W.2
-
15
-
-
0034187573
-
Characterization of a pressurizable two-step atomizer for atomic absorption spectrometry
-
Frech W., Hadgu N., Hendriksson D., Radziuk B., Rödel G., and Tamm R. Characterization of a pressurizable two-step atomizer for atomic absorption spectrometry. Spectrochim. Acta Part B 55 (2000) 461-472
-
(2000)
Spectrochim. Acta Part B
, vol.55
, pp. 461-472
-
-
Frech, W.1
Hadgu, N.2
Hendriksson, D.3
Radziuk, B.4
Rödel, G.5
Tamm, R.6
-
16
-
-
0030291024
-
Characterization of a modified two-step furnace for atomic absorption spectrometry for selective volatilization of iron species in hemin
-
Smith C.M.M., and Harnly J.M. Characterization of a modified two-step furnace for atomic absorption spectrometry for selective volatilization of iron species in hemin. J. Anal. At. Spectrom. 11 (1996) 1055-1061
-
(1996)
J. Anal. At. Spectrom.
, vol.11
, pp. 1055-1061
-
-
Smith, C.M.M.1
Harnly, J.M.2
-
17
-
-
0032027665
-
A new design of the two-component atomizer for the direct determination of medium and volatile elements in high-purity solid refractory metals by electrothermal atomic absorption spectrometry
-
Docekal B. A new design of the two-component atomizer for the direct determination of medium and volatile elements in high-purity solid refractory metals by electrothermal atomic absorption spectrometry. Spectrochim. Acta Part B 53 (1998) 427-435
-
(1998)
Spectrochim. Acta Part B
, vol.53
, pp. 427-435
-
-
Docekal, B.1
-
18
-
-
0035966856
-
Direct atomic absorption determination of cadmium and lead in strongly interfering matrices by double vaporization with a two-step electrothermal atomizer
-
Grinshtein I.L., Vilpan Y.A., Saraev A.V., and Vasilieva L.A. Direct atomic absorption determination of cadmium and lead in strongly interfering matrices by double vaporization with a two-step electrothermal atomizer. Spectrochim. Acta Part B 56 (2001) 261-274
-
(2001)
Spectrochim. Acta Part B
, vol.56
, pp. 261-274
-
-
Grinshtein, I.L.1
Vilpan, Y.A.2
Saraev, A.V.3
Vasilieva, L.A.4
-
19
-
-
8644290868
-
Comparative study of the effect of sample matrix on the atomic absorption of high-volatile elements in two-step and conventional atomizers
-
Nagulin K.Yu., and Gil'mutdinov A.Kh. Comparative study of the effect of sample matrix on the atomic absorption of high-volatile elements in two-step and conventional atomizers. J. Anal. Chem. 59 (2004) 1042-1049
-
(2004)
J. Anal. Chem.
, vol.59
, pp. 1042-1049
-
-
Nagulin, K.Yu.1
Gil'mutdinov, A.Kh.2
-
20
-
-
0347351054
-
Determination of trace impurities in titanium dioxide by slurry sampling electrothermal atomic absorption spectrometry
-
Huang M.D., Krivan V., Welz B., and Schlemmer G. Determination of trace impurities in titanium dioxide by slurry sampling electrothermal atomic absorption spectrometry. Spectrochim. Acta Part B 52 (1997) 1747-1762
-
(1997)
Spectrochim. Acta Part B
, vol.52
, pp. 1747-1762
-
-
Huang, M.D.1
Krivan, V.2
Welz, B.3
Schlemmer, G.4
-
21
-
-
0542444492
-
Multi-element characterization of high-purity titanium dioxide by neutron activation analysis
-
Wildhagen D., and Krivan V. Multi-element characterization of high-purity titanium dioxide by neutron activation analysis. Fresenius' J. Anal. Chem. 359 (1997) 230-238
-
(1997)
Fresenius' J. Anal. Chem.
, vol.359
, pp. 230-238
-
-
Wildhagen, D.1
Krivan, V.2
-
22
-
-
0030143046
-
Multi-element characterization of titanium (IV) oxide by electrothermal atomic absorption spectrometry, inductively coupled plasma atomic emission spectrometry, inductively coupled plasma mass spectrometry and total reflection X-ray fluorescence spectrometry after matrix-analyte separation
-
Wildhagen D., Krivan V., Gercken B., and Pavel J. Multi-element characterization of titanium (IV) oxide by electrothermal atomic absorption spectrometry, inductively coupled plasma atomic emission spectrometry, inductively coupled plasma mass spectrometry and total reflection X-ray fluorescence spectrometry after matrix-analyte separation. J. Anal. At. Spectrom. 11 (1996) 371-377
-
(1996)
J. Anal. At. Spectrom.
, vol.11
, pp. 371-377
-
-
Wildhagen, D.1
Krivan, V.2
Gercken, B.3
Pavel, J.4
|