-
1
-
-
0034143877
-
Biaxial mechanical properties of the natural and glutaraldehyde treated aortic valve cusp-Part I: experimental results
-
Billiar K.L., and Sacks M.S. Biaxial mechanical properties of the natural and glutaraldehyde treated aortic valve cusp-Part I: experimental results. Journal of Biomechanical Engineering 122 1 (2000) 23-30
-
(2000)
Journal of Biomechanical Engineering
, vol.122
, Issue.1
, pp. 23-30
-
-
Billiar, K.L.1
Sacks, M.S.2
-
2
-
-
0003694636
-
-
Butterworths, Washington, DC
-
Frisch-Fay R. Flexible Bars (1962), Butterworths, Washington, DC
-
(1962)
Flexible Bars
-
-
Frisch-Fay, R.1
-
3
-
-
12944257433
-
Effects of mechanical fatigue on the bending properties of the porcine bioprosthetic heart valve
-
Gloeckner D.C., Billiar K.L., and Sacks M.S. Effects of mechanical fatigue on the bending properties of the porcine bioprosthetic heart valve. ASAIO Journal 45 1 (1999) 59-63
-
(1999)
ASAIO Journal
, vol.45
, Issue.1
, pp. 59-63
-
-
Gloeckner, D.C.1
Billiar, K.L.2
Sacks, M.S.3
-
4
-
-
0022929725
-
Influence of stent height upon stresses on the cusps of closed bioprosthetic valves
-
Hamid M.S., Sabbah H.N., and Stein P.D. Influence of stent height upon stresses on the cusps of closed bioprosthetic valves. Journal of Biomechanics 19 (1986) 759-769
-
(1986)
Journal of Biomechanics
, vol.19
, pp. 759-769
-
-
Hamid, M.S.1
Sabbah, H.N.2
Stein, P.D.3
-
5
-
-
0024185071
-
Some computational aspects of nonlinear stress analysis of bioprosthetic heart valves
-
Spilker R., and Simon B. (Eds), Asme, New York
-
Hamid M.S., Sabbah H.N., and Stein P.D. Some computational aspects of nonlinear stress analysis of bioprosthetic heart valves. In: Spilker R., and Simon B. (Eds). Computational Methods in Bioengineering (1988), Asme, New York 335-346
-
(1988)
Computational Methods in Bioengineering
, pp. 335-346
-
-
Hamid, M.S.1
Sabbah, H.N.2
Stein, P.D.3
-
6
-
-
0027642707
-
Numerical simulation of leaflet flexure in bioprosthetic valves mounted on rigid and expansile stents
-
Krucinski S., Vesely I., Dokainish M.A., and Campbell G. Numerical simulation of leaflet flexure in bioprosthetic valves mounted on rigid and expansile stents. Journal of Biomechanics 26 (1993) 929-943
-
(1993)
Journal of Biomechanics
, vol.26
, pp. 929-943
-
-
Krucinski, S.1
Vesely, I.2
Dokainish, M.A.3
Campbell, G.4
-
7
-
-
27744572738
-
The effects of cellular contraction on aortic valve leaflet flexural stiffness
-
Merryman W.D., Huang H.Y.S., Schoen F.J., and Sacks M.S. The effects of cellular contraction on aortic valve leaflet flexural stiffness. Journal of Biomechanics 39 1 (2006) 88-96
-
(2006)
Journal of Biomechanics
, vol.39
, Issue.1
, pp. 88-96
-
-
Merryman, W.D.1
Huang, H.Y.S.2
Schoen, F.J.3
Sacks, M.S.4
-
8
-
-
4444245320
-
The effects of collagen fiber orientation on the flexural properties of pericardial heterograft biomaterials
-
Mirnajafi A., Raymer J., Scott M.J., and Sacks M.S. The effects of collagen fiber orientation on the flexural properties of pericardial heterograft biomaterials. Biomaterials 26 7 (2005) 795-804
-
(2005)
Biomaterials
, vol.26
, Issue.7
, pp. 795-804
-
-
Mirnajafi, A.1
Raymer, J.2
Scott, M.J.3
Sacks, M.S.4
-
9
-
-
0003474751
-
-
Cambridge University Press, Cambridge
-
Press W.H., Flannery B.P., Teukolsky S.A., and Vetterling W.T. Numerical Receipes in C (1988), Cambridge University Press, Cambridge
-
(1988)
Numerical Receipes in C
-
-
Press, W.H.1
Flannery, B.P.2
Teukolsky, S.A.3
Vetterling, W.T.4
-
11
-
-
0030641773
-
Aortic valve structure-function correlations: role of elastic fibers no longer a stretch of the imagination
-
Schoen F. Aortic valve structure-function correlations: role of elastic fibers no longer a stretch of the imagination. Journal of Heart Valve Disease 6 (1997) 1-6
-
(1997)
Journal of Heart Valve Disease
, vol.6
, pp. 1-6
-
-
Schoen, F.1
-
12
-
-
33751218950
-
-
Sugimoto, H., Shimada, K., Sacks, M.S., in press. The effects of leaflet stiffness on the dynamic geometry of the aortic heart valve leaflet. Journal of Biomechanical Engineering, in press.
-
-
-
-
13
-
-
27444446944
-
Simulated bioprosthetic heart valve deformation under quasi-static loading
-
Sun W., Abad A., and Sacks M.S. Simulated bioprosthetic heart valve deformation under quasi-static loading. Journal of Biomechanial Engineering 127 6 (2005) 905-914
-
(2005)
Journal of Biomechanial Engineering
, vol.127
, Issue.6
, pp. 905-914
-
-
Sun, W.1
Abad, A.2
Sacks, M.S.3
-
15
-
-
0026575408
-
Micromechanics of the fibrosa and the ventricularis in aortic valve leaflets
-
Vesely I., and Noseworthy R. Micromechanics of the fibrosa and the ventricularis in aortic valve leaflets. Journal of Biomechanics 25 1 (1992) 101-113
-
(1992)
Journal of Biomechanics
, vol.25
, Issue.1
, pp. 101-113
-
-
Vesely, I.1
Noseworthy, R.2
-
16
-
-
0023755406
-
Tissue buckling as a mechanism of bioprosthetic valve failure
-
Vesely I., Boughner D., and Song T. Tissue buckling as a mechanism of bioprosthetic valve failure. Annals of Thoracic Surgery 46 (1988) 302-308
-
(1988)
Annals of Thoracic Surgery
, vol.46
, pp. 302-308
-
-
Vesely, I.1
Boughner, D.2
Song, T.3
|