메뉴 건너뛰기




Volumn 131, Issue 5, 2006, Pages 407-410

Pullout resistance of conventional pedicle screw implantation in comparison to fluoroscopic computer-assisted technique;Ausrissfestigkeit implantierter pedikelschrauben in konventioneller und fluoroskopisch-navigierter technik

Author keywords

Computer assisted surgery; Fluoroscopy; Mechanical stability; Pedicle screw

Indexed keywords

ARTICLE; BIOMECHANICS; COMPARATIVE STUDY; COMPUTER AIDED DESIGN; FLUOROSCOPY; LUMBAR SPINAL CORD; PEDICLE SCREW;

EID: 33751208306     PISSN: 0044409X     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2006-950383     Document Type: Article
Times cited : (5)

References (23)
  • 1
    • 0034061781 scopus 로고    scopus 로고
    • Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine
    • Amiot LP, Lang K, Putzier M et al. Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 2000; 25: 606-614
    • (2000) Spine , vol.25 , pp. 606-614
    • Amiot, L.P.1    Lang, K.2    Putzier, M.3
  • 2
    • 0024798039 scopus 로고
    • In-vitro spinal arthrodesis implant mechanical testing protocols
    • Ashmann RB, Bechtold JE, Edwards WT. In-vitro spinal arthrodesis implant mechanical testing protocols. J Spin Dis 1989; 275
    • (1989) J Spin Dis , vol.275
    • Ashmann, R.B.1    Bechtold, J.E.2    Edwards, W.T.3
  • 3
    • 0034491195 scopus 로고    scopus 로고
    • Computer-assisted fluoroscopic targeting system for pedicle screw insertion
    • Choi WW, Green BA, Levi AD. Computer-assisted fluoroscopic targeting system for pedicle screw insertion. Neurosurgery 2000; 47: 872-878
    • (2000) Neurosurgery , vol.47 , pp. 872-878
    • Choi, W.W.1    Green, B.A.2    Levi, A.D.3
  • 4
    • 0025153831 scopus 로고
    • Influence of bone mineral density on the fixation of thoracolumbar implants
    • Coe JD, Warden KE, Herzig MA et al. Influence of bone mineral density on the fixation of thoracolumbar implants. Spine 1990; 15: 903-907
    • (1990) Spine , vol.15 , pp. 903-907
    • Coe, J.D.1    Warden, K.E.2    Herzig, M.A.3
  • 5
    • 0027484342 scopus 로고
    • Complications associated with the technique of pedicle screw fixation
    • Esses SI, Sachs BL, Dreyzin V. Complications associated with the technique of pedicle screw fixation. Spine 1993; 18: 2231-2239
    • (1993) Spine , vol.18 , pp. 2231-2239
    • Esses, S.I.1    Sachs, B.L.2    Dreyzin, V.3
  • 6
    • 0025267440 scopus 로고
    • Accuracy of pedicular screw placement in vivo
    • Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine 1990; 15: 11-14
    • (1990) Spine , vol.15 , pp. 11-14
    • Gertzbein, S.D.1    Robbins, S.E.2
  • 7
    • 0024363897 scopus 로고
    • Effect of preservation medium on the mechanical properties of cat bones
    • James C, Goh H, Ang J, Bose K. Effect of preservation medium on the mechanical properties of cat bones. Acta Orthop Scand 1989; 60: 465-467
    • (1989) Acta Orthop Scand , vol.60 , pp. 465-467
    • James, C.1    Goh, H.2    Ang, J.3    Bose, K.4
  • 8
    • 0032989622 scopus 로고    scopus 로고
    • Accurate pedicle screw insertion under the control of a computer-assisted image guiding system: Laboratory test and clinical study
    • Kamimura M, Ebara S, Itoh H et al. Accurate pedicle screw insertion under the control of a computer-assisted image guiding system: Laboratory test and clinical study. J Orthop Sci 1999; 4: 197-206
    • (1999) J Orthop Sci , vol.4 , pp. 197-206
    • Kamimura, M.1    Ebara, S.2    Itoh, H.3
  • 9
    • 0035865441 scopus 로고    scopus 로고
    • Computer-assisted thoracic pedicle screw placement: An in vitro feasibility study
    • Kim KD, Patrick Johnson J, Bloch BO et al. Computer-assisted thoracic pedicle screw placement: An in vitro feasibility study. Spine 2001; 26: 360-364
    • (2001) Spine , vol.26 , pp. 360-364
    • Kim, K.D.1    Patrick Johnson, J.2    Bloch, B.O.3
  • 10
    • 0033834616 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion with and without computer assistance: A randomised controlled clinical study in 100 consecutive patients
    • Laine T, Lund T, Ylikoski M et al. Accuracy of pedicle screw insertion with and without computer assistance: A randomised controlled clinical study in 100 consecutive patients. Eur Spine J 2000; 9: 235-240
    • (2000) Eur Spine J , vol.9 , pp. 235-240
    • Laine, T.1    Lund, T.2    Ylikoski, M.3
  • 11
    • 0031696110 scopus 로고    scopus 로고
    • Pedicle screw placement using image-guided techniques
    • Merloz P, Tonetti J, Pittet L et al. Pedicle screw placement using image-guided techniques. Clin Orthop 1998; 354: 39-48
    • (1998) Clin Orthop , vol.354 , pp. 39-48
    • Merloz, P.1    Tonetti, J.2    Pittet, L.3
  • 12
    • 0037442352 scopus 로고    scopus 로고
    • Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: A cadaver study
    • Mirza SK, Wiggins GC, Kuntz C, York JE, Bellabarba C, Knonodi MA, Chapman JR, Shaffrey CI. Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: a cadaver study. Spine 2003; 28: 402-413
    • (2003) Spine , vol.28 , pp. 402-413
    • Mirza, S.K.1    Wiggins, G.C.2    Kuntz, C.3    York, J.E.4    Bellabarba, C.5    Knonodi, M.A.6    Chapman, J.R.7    Shaffrey, C.I.8
  • 13
    • 2242434320 scopus 로고    scopus 로고
    • Einbringung von pedikelschrauben unter einsatz unterschiedlicher unterstützungsverfahren
    • Reichle E, Sellenschloh K, Morlock M, Eggers C. Einbringung von Pedikelschrauben unter Einsatz unterschiedlicher Unterstützungsverfahren. Orthopäde 2002; 31: 368-371
    • (2002) Orthopäde , vol.31 , pp. 368-371
    • Reichle, E.1    Sellenschloh, K.2    Morlock, M.3    Eggers, C.4
  • 14
    • 0036128620 scopus 로고    scopus 로고
    • Increased pedicle screw pullout strength with vertebroplasty augmentation in osteoporotic spines
    • Sarzier JS, Evans AJ, Cahill DW. Increased pedicle screw pullout strength with vertebroplasty augmentation in osteoporotic spines. J Neurosurg 2002; 96: 309-312
    • (2002) J Neurosurg , vol.96 , pp. 309-312
    • Sarzier, J.S.1    Evans, A.J.2    Cahill, D.W.3
  • 15
    • 0033870387 scopus 로고    scopus 로고
    • Computergestützte wirbelsäulenchirurgie
    • Schlenzka D, Laine T, Lund T. Computergestützte Wirbelsä ulenchirurgie. Orthopäde 2000; 29: 658-669
    • (2000) Orthopäde , vol.29 , pp. 658-669
    • Schlenzka, D.1    Laine, T.2    Lund, T.3
  • 16
    • 1542288140 scopus 로고    scopus 로고
    • Genauigkeit der CT-basierten navigation von pedikelschrauben an der brustwirbelsäule im vergleich zur konventionellen technik
    • Schnake KJ, König B, Berth U, Schroeder RJ, Kandziora F, Stöckle U, Raschke M, Haas NP. Genauigkeit der CT-basierten Navigation von Pedikelschrauben an der Brustwirbelsäule im Vergleich zur konventionellen Technik. Unfallchirurg 2004; 107: 104-112
    • (2004) Unfallchirurg , vol.107 , pp. 104-112
    • Schnake, K.J.1    König, B.2    Berth, U.3    Schroeder, R.J.4    Kandziora, F.5    Stöckle, U.6    Raschke, M.7    Haas, N.P.8
  • 17
    • 0025988460 scopus 로고
    • An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine
    • Soshi S, Shiba R, Kondo H, Murota K. An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine 1991; 16: 1335-1341
    • (1991) Spine , vol.16 , pp. 1335-1341
    • Soshi, S.1    Shiba, R.2    Kondo, H.3    Murota, K.4
  • 18
    • 0027493601 scopus 로고
    • Spinal pedicle fixation: Confirmation of an image-based technique for screw placement
    • Steinmann JC, Herkowitz HN, El-Kommos H et al. Spinal pedicle fixation: confirmation of an image-based technique for screw placement. Spine 1993; 18: 1856-1861
    • (1993) Spine , vol.18 , pp. 1856-1861
    • Steinmann, J.C.1    Herkowitz, H.N.2    El-Kommos, H.3
  • 19
    • 0026445667 scopus 로고
    • Anatomic and technical considerations of pedicle screw fixation
    • Weinstein JN, Rydevik BL, Rauschning W. Anatomic and technical considerations of pedicle screw fixation. Clin Orthop 1992; 284: 34-36
    • (1992) Clin Orthop , vol.284 , pp. 34-36
    • Weinstein, J.N.1    Rydevik, B.L.2    Rauschning, W.3
  • 20
    • 0023790873 scopus 로고
    • Spinal pedicle fixation: Reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement
    • Weinstein JN, Spratt KF, Spengler D et al. Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 1988; 13: 1012-1018
    • (1988) Spine , vol.13 , pp. 1012-1018
    • Weinstein, J.N.1    Spratt, K.F.2    Spengler, D.3
  • 21
    • 0002456783 scopus 로고
    • History of pedicle screw fixation of the spine
    • Wiltse LL. History of pedicle screw fixation of the spine. Spine State Art Rev 1992; 6: 1-10
    • (1992) Spine State Art Rev , vol.6 , pp. 1-10
    • Wiltse, L.L.1
  • 23
    • 0035065411 scopus 로고    scopus 로고
    • Stereotactic navigation for placement of pedicle screws in the thoracic spine
    • Youkilis AS, Quint DJ, McGillicuddyJE et al. Stereotactic navigation for placement of pedicle screws in the thoracic spine. Neurosurgery 2001; 48: 771-778
    • (2001) Neurosurgery , vol.48 , pp. 771-778
    • Youkilis, A.S.1    Quint, D.J.2    McGillicuddy, J.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.