메뉴 건너뛰기




Volumn 42, Issue 3, 2007, Pages 1135-1141

The assessment of the performance of a windcatcher system using computational fluid dynamics

Author keywords

Buildings; CFD; Green features; Natural ventilation; Windcatcher

Indexed keywords

AERODYNAMICS; BUILDINGS; COMPUTATIONAL FLUID DYNAMICS; NUMERICAL ANALYSIS; WIND TUNNELS;

EID: 33751185345     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2005.12.015     Document Type: Article
Times cited : (106)

References (19)
  • 1
    • 20844451257 scopus 로고    scopus 로고
    • The application of computational fluid dynamics to the assessment of green features in buildings. Part 1: wing walls
    • Mak C.M., Cheng C., and Niu J.L. The application of computational fluid dynamics to the assessment of green features in buildings. Part 1: wing walls. Architectural Science Review 48 1 (2005) 121-134
    • (2005) Architectural Science Review , vol.48 , Issue.1 , pp. 121-134
    • Mak, C.M.1    Cheng, C.2    Niu, J.L.3
  • 2
    • 33751173714 scopus 로고    scopus 로고
    • Awbi HB, Elmualim AA. Full scale model windcatcher performance evaluation using a wind tunnel. In: Proceedings of the World renewable energy congress VII, 2002.
  • 3
    • 0028486269 scopus 로고
    • Viability of wind towers in achieving summer comfort in the hot arid regions of the Middle-East
    • Bahadori M.N. Viability of wind towers in achieving summer comfort in the hot arid regions of the Middle-East. Renewable Energy 5 (1994) 879-892
    • (1994) Renewable Energy , vol.5 , pp. 879-892
    • Bahadori, M.N.1
  • 4
    • 33751169000 scopus 로고    scopus 로고
    • Elmualim AA, Awib HB, Teekaram AJ, Brown RG. Evaluating the Performance of a Windcatcher System Using Wind Tunnel Testing. In: Proceedings of the 22nd annual AIVC conference, 11-14 September 2001, Bath, UK. Belgium: Air Infilteration and Ventilation Centre, 1, INIVEEIG, 2001. p. 29.1-29.12.
  • 7
    • 33751161749 scopus 로고    scopus 로고
    • Swainson MJ. Evaluation of the potential of solar chimneys to drive natural ventilation in non-domestic buildings, PhD Dissertation, Cranfield University, UK, 1997.
  • 8
    • 0026897785 scopus 로고
    • Computational fluid dynamics for building airflow prediction-current status and capabilities
    • Jones P.J., and Whittle G.E. Computational fluid dynamics for building airflow prediction-current status and capabilities. Building and Environment 27 3 (1992) 321-338
    • (1992) Building and Environment , vol.27 , Issue.3 , pp. 321-338
    • Jones, P.J.1    Whittle, G.E.2
  • 9
    • 0026759253 scopus 로고
    • Two-dimension simulation of the airflow and thermal comfort in a room with open-window and indoor cooling systems
    • Niu J.L., and Kooi J.V.D. Two-dimension simulation of the airflow and thermal comfort in a room with open-window and indoor cooling systems. Energy and Buildings 18 1 (1992) 65-75
    • (1992) Energy and Buildings , vol.18 , Issue.1 , pp. 65-75
    • Niu, J.L.1    Kooi, J.V.D.2
  • 10
    • 0030239398 scopus 로고    scopus 로고
    • Application of computational fluid dynamics in building services engineering
    • Chow W.K. Application of computational fluid dynamics in building services engineering. Building and Environment 31 (1996) 425-436
    • (1996) Building and Environment , vol.31 , pp. 425-436
    • Chow, W.K.1
  • 11
  • 12
    • 0024921295 scopus 로고
    • Application of computational fluid dynamics in room ventilation
    • Awbi H.B. Application of computational fluid dynamics in room ventilation. Building and Environment 24 1 (1989) 73-84
    • (1989) Building and Environment , vol.24 , Issue.1 , pp. 73-84
    • Awbi, H.B.1
  • 13
    • 0036736735 scopus 로고    scopus 로고
    • A study of natural ventilation in a kitchen using computational fluid dynamics (CFD)
    • Mak C.M., and Yik Francis W.H. A study of natural ventilation in a kitchen using computational fluid dynamics (CFD). Architectural Science Review 45 (2002) 1-8
    • (2002) Architectural Science Review , vol.45 , pp. 1-8
    • Mak, C.M.1    Yik Francis, W.H.2
  • 14
    • 33751178454 scopus 로고    scopus 로고
    • Influence of a depth of a recessed space to flow due to air-conditioner heat rejection
    • Bojic M., Lee M., and Yik F. Influence of a depth of a recessed space to flow due to air-conditioner heat rejection. Energy and Buildings 1349 (2001) 1-11
    • (2001) Energy and Buildings , vol.1349 , pp. 1-11
    • Bojic, M.1    Lee, M.2    Yik, F.3
  • 15
    • 0012586345 scopus 로고    scopus 로고
    • The application of computational fluid dynamics to the prediction of flow-generated noise in low speed flow ducts. Part 1: fluctuating drag forces on a flow spoiler
    • Mak C.M., and Oldham D.J. The application of computational fluid dynamics to the prediction of flow-generated noise in low speed flow ducts. Part 1: fluctuating drag forces on a flow spoiler. Journal of Building Acoustics 5 2 (1998) 123-141
    • (1998) Journal of Building Acoustics , vol.5 , Issue.2 , pp. 123-141
    • Mak, C.M.1    Oldham, D.J.2
  • 16
    • 0012593506 scopus 로고    scopus 로고
    • The application of computational fluid dynamics to the prediction of flow-generated noise in low speed flow ducts. Part 2: Turbulence-based prediction technique
    • Mak C.M., and Oldham D.J. The application of computational fluid dynamics to the prediction of flow-generated noise in low speed flow ducts. Part 2: Turbulence-based prediction technique. Journal of Building Acoustics 5 3 (1998) 199-213
    • (1998) Journal of Building Acoustics , vol.5 , Issue.3 , pp. 199-213
    • Mak, C.M.1    Oldham, D.J.2
  • 18
    • 33751167302 scopus 로고    scopus 로고
    • Niu JL, Zhu ZJ. Numerical study of wind flow around a CAARC Standard tall building in an atmospheric boundary layer. ASME Journal of Fluid Engineering, 2004.
  • 19
    • 0036503274 scopus 로고    scopus 로고
    • Setting the scene: CFD and symposium overview
    • Murakami S. Setting the scene: CFD and symposium overview. Wind and Structures 5 2-4 (2002) 83-88
    • (2002) Wind and Structures , vol.5 , Issue.2-4 , pp. 83-88
    • Murakami, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.