메뉴 건너뛰기




Volumn 51, Issue 21, 2006, Pages

A method detection limit for potential in vivo arsenic measurements with a 50 W x-ray tube

Author keywords

[No Author keywords available]

Indexed keywords

ARSENIC; COMPUTER SIMULATION; DRUG DOSAGE; MEASUREMENT THEORY; NUMERICAL METHODS; PRODUCT DESIGN; TISSUE; X RAY APPARATUS;

EID: 33751178600     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/51/21/N01     Document Type: Article
Times cited : (12)

References (20)
  • 2
    • 0019498828 scopus 로고
    • Cadmium in man measured in vivo by x-ray fluorescence analysis
    • Ahlgren L and Mattsson S 1981 Cadmium in man measured in vivo by x-ray fluorescence analysis Phys. Med. Biol. 26 19-26
    • (1981) Phys. Med. Biol. , vol.26 , Issue.1 , pp. 19-26
    • Ahlgren, L.1    Mattsson, S.2
  • 3
    • 0042737759 scopus 로고    scopus 로고
    • Simultaneous determination of iron, copper and zinc concentrations in skin phantoms using XRF spectrometry
    • Bagshaw A P and Farquharson M J 2002 Simultaneous determination of iron, copper and zinc concentrations in skin phantoms using XRF spectrometry X-Ray Spectrom. 31 47-52
    • (2002) X-Ray Spectrom. , vol.31 , Issue.1 , pp. 47-52
    • Bagshaw, A.P.1    Farquharson, M.J.2
  • 4
    • 36049055113 scopus 로고
    • Reevaluation of X-ray atomic energy levels
    • Bearden J A and Burr A F 1967 Reevaluation of X-ray atomic energy levels Rev. Mod. Phys. 39 125-42
    • (1967) Rev. Mod. Phys. , vol.39 , Issue.1 , pp. 125-142
    • Bearden, J.A.1    Burr, A.F.2
  • 8
    • 0029267020 scopus 로고
    • Arsenic in ground water in six districts of West Bengal, India: The biggest arsenic calamity in the world: II. Arsenic concentration in drinking water, hair, mails, urine, skin-scale and liver tissue (biopsy) of the affected people
    • Das D, Chatterjee A, Mandal B K, Samanta G and Chakraborti D 1995 Arsenic in ground water in six districts of West Bengal, India: the biggest arsenic calamity in the world: II. Arsenic concentration in drinking water, hair, mails, urine, skin-scale and liver tissue (biopsy) of the affected people Analyst 120 917-24
    • (1995) Analyst , vol.120 , Issue.3 , pp. 917-924
    • Das, D.1    Chatterjee, A.2    Mandal, B.K.3    Samanta, G.4    Chakraborti, D.5
  • 10
    • 0022380017 scopus 로고
    • Noninvasive analysis of skin iron and zinc levels in b-thalassemia major and intermedia
    • Gorodetsky R, Goldfarb A, Dagan I and Rachmilewitz E A 1985 Noninvasive analysis of skin iron and zinc levels in b-thalassemia major and intermedia J. Lab. Clin. Med. 105 44-51
    • (1985) J. Lab. Clin. Med. , vol.105 , pp. 44-51
    • Gorodetsky, R.1    Goldfarb, A.2    Dagan, I.3    Rachmilewitz, E.A.4
  • 13
    • 0033622698 scopus 로고    scopus 로고
    • Arsenic in groundwater and health problems in Bangladesh
    • Karim M M 2000 Arsenic in groundwater and health problems in Bangladesh Water Res. 34 304-10
    • (2000) Water Res. , vol.34 , Issue.1 , pp. 304-310
    • Karim, M.M.1
  • 14
    • 84883834637 scopus 로고
    • Hematologic aspects of arsenic intoxication
    • Kyle R A and Pease G L 1965 Hematologic aspects of arsenic intoxication N. Engl. J. Med. 273 18-23
    • (1965) N. Engl. J. Med. , vol.273 , pp. 18-23
    • Kyle, R.A.1    Pease, G.L.2
  • 15
    • 0030983524 scopus 로고    scopus 로고
    • The feasibility of measuring bone uranium concentrations in vivo using source excited K x-ray fluorescence
    • O'Meara J M, Chettle D R, McNeill F E and Webber C E 1997 The feasibility of measuring bone uranium concentrations in vivo using source excited K x-ray fluorescence Phys. Med. Biol. 42 1109-20
    • (1997) Phys. Med. Biol. , vol.42 , Issue.6 , pp. 1109-1120
    • O'Meara, J.M.1    Chettle, D.R.2    McNeill, F.E.3    Webber, C.E.4
  • 18
    • 0030970670 scopus 로고    scopus 로고
    • Arsenic and the skin
    • Schwartz R A 1997 Arsenic and the skin Int. J. Dermatol. 36 241-50
    • (1997) Int. J. Dermatol. , vol.36 , Issue.4 , pp. 241-250
    • Schwartz, R.A.1
  • 20
    • 14544284561 scopus 로고    scopus 로고
    • Estimation of a method detection limit for an in vivo XRF arsenic detection system
    • Studinski R C N, McNeill F E, Chettle D R and O'Meara J M 2005 Estimation of a method detection limit for an in vivo XRF arsenic detection system Phys. Med. Biol. 50 521-30
    • (2005) Phys. Med. Biol. , vol.50 , Issue.3 , pp. 521-530
    • Studinski, R.C.N.1    McNeill, F.E.2    Chettle, D.R.3    O'Meara, J.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.