메뉴 건너뛰기




Volumn 82, Issue 6, 2006, Pages 2292-2294

Left Ventricular Pacing Site-Timing Optimization During Biventricular Pacing Using a Multi-Electrode Patch

Author keywords

[No Author keywords available]

Indexed keywords

ANTIBIOTIC AGENT;

EID: 33751169368     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2006.04.094     Document Type: Article
Times cited : (16)

References (10)
  • 1
    • 0035932533 scopus 로고    scopus 로고
    • Effects of multi-site biventricular pacing in patients with heart failure and intraventricular conduction delay
    • Cazeau S., Leclercq C., Lavergne T., et al. Effects of multi-site biventricular pacing in patients with heart failure and intraventricular conduction delay. N Eng J Med 344 (2001) 873-880
    • (2001) N Eng J Med , vol.344 , pp. 873-880
    • Cazeau, S.1    Leclercq, C.2    Lavergne, T.3
  • 2
    • 2642521333 scopus 로고    scopus 로고
    • Epicardial left ventricular lead placement for cardiac resynchronization therapy: Optimal pace site selection with pressure-volume loops
    • Dekker L.A.J., Phelps B., Dijkman B., et al. Epicardial left ventricular lead placement for cardiac resynchronization therapy: Optimal pace site selection with pressure-volume loops. J Thoracic Cardiovasc Surg 127 (2004) 1641-1647
    • (2004) J Thoracic Cardiovasc Surg , vol.127 , pp. 1641-1647
    • Dekker, L.A.J.1    Phelps, B.2    Dijkman, B.3
  • 3
    • 0033545587 scopus 로고    scopus 로고
    • Transvenous biventricular pacing for heart failure: can the obstacles be oversome?
    • Auricchio A., Klein H., Tockman B., et al. Transvenous biventricular pacing for heart failure: can the obstacles be oversome?. Am J Cardiol 83 (1999) 136D-142D
    • (1999) Am J Cardiol , vol.83
    • Auricchio, A.1    Klein, H.2    Tockman, B.3
  • 4
    • 0034597603 scopus 로고    scopus 로고
    • Should stimulation site be tailored in the individual heart failure patient?
    • Butter C., Auricchio A., Stellbrink C., et al. Should stimulation site be tailored in the individual heart failure patient?. Am J Cardiol 86 (2000) K144-K151
    • (2000) Am J Cardiol , vol.86
    • Butter, C.1    Auricchio, A.2    Stellbrink, C.3
  • 5
    • 0033830204 scopus 로고    scopus 로고
    • Cardiac pacing in heart failure patients with left bundle branch block: impact of pacing site for optimizing left ventricular resynchronization
    • Pappone C., Rosanio S., Oreto G., et al. Cardiac pacing in heart failure patients with left bundle branch block: impact of pacing site for optimizing left ventricular resynchronization. Ital Heart J 1 (2000) 464-469
    • (2000) Ital Heart J , vol.1 , pp. 464-469
    • Pappone, C.1    Rosanio, S.2    Oreto, G.3
  • 6
    • 0037028608 scopus 로고    scopus 로고
    • Doppler myocardial imaging to evaluate the effectiveness of pacing sites in patients receiving biventricular pacing
    • Ansalone G., Giannantoni P., Ricci R., Trambaiolo P., Fedele F., and Santini M. Doppler myocardial imaging to evaluate the effectiveness of pacing sites in patients receiving biventricular pacing. J Am Coll Cardiol 39 (2002) 489-499
    • (2002) J Am Coll Cardiol , vol.39 , pp. 489-499
    • Ansalone, G.1    Giannantoni, P.2    Ricci, R.3    Trambaiolo, P.4    Fedele, F.5    Santini, M.6
  • 7
    • 0034828176 scopus 로고    scopus 로고
    • Six year experience of transvenous left ventricular lead implantation for permanent biventricular pacing in patients with advanced heart failure: technical aspects
    • Alonso C., Leclercq C., d'Allonnes F.R., et al. Six year experience of transvenous left ventricular lead implantation for permanent biventricular pacing in patients with advanced heart failure: technical aspects. Heart 86 (2001) 405-410
    • (2001) Heart , vol.86 , pp. 405-410
    • Alonso, C.1    Leclercq, C.2    d'Allonnes, F.R.3
  • 8
    • 0035119301 scopus 로고    scopus 로고
    • Adverse events with transvenous left ventricular pacing in patients with severe heart failure: early experience from a single centre
    • Valls-Bertault V., Mansourati J., Gilard M., Etienne Y., Munier S., and Blanc J.J. Adverse events with transvenous left ventricular pacing in patients with severe heart failure: early experience from a single centre. Europace 3 (2001) 60-63
    • (2001) Europace , vol.3 , pp. 60-63
    • Valls-Bertault, V.1    Mansourati, J.2    Gilard, M.3    Etienne, Y.4    Munier, S.5    Blanc, J.J.6
  • 9
    • 1842685244 scopus 로고    scopus 로고
    • Minimal invasive epicardial lead implantation: optimizing cardiac resynchronization with a new mapping device for epicardial lead placement
    • Maessen J.G., Phelps B., Dekker L.A.J., and Dijkman B. Minimal invasive epicardial lead implantation: optimizing cardiac resynchronization with a new mapping device for epicardial lead placement. Eur J Cardiothorac Surg 25 (2004) 894-896
    • (2004) Eur J Cardiothorac Surg , vol.25 , pp. 894-896
    • Maessen, J.G.1    Phelps, B.2    Dekker, L.A.J.3    Dijkman, B.4
  • 10
    • 0037502604 scopus 로고    scopus 로고
    • Cardiac resynchronization therapy: a review of clinical trials and criteria for identifying the appropriate patient
    • Abraham W.T. Cardiac resynchronization therapy: a review of clinical trials and criteria for identifying the appropriate patient. Rev Cardiovasc Med 4 (2003) S30-S37
    • (2003) Rev Cardiovasc Med , vol.4
    • Abraham, W.T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.