메뉴 건너뛰기




Volumn 25, Issue 3, 2006, Pages 373-381

A possible quality control protocol for Doppler ultrasound for organizational time optimization

Author keywords

Doppler; Ultrasound quality assurance; Ultrasound quality control

Indexed keywords

ACCURACY; ARTICLE; CALIBRATION; COLOR ULTRASOUND FLOWMETRY; DOPPLER ECHOGRAPHY; DOPPLER FLOWMETRY; PERFORMANCE; PRIORITY JOURNAL; QUALITY CONTROL; QUANTITATIVE ANALYSIS;

EID: 33751099308     PISSN: 03929078     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (22)
  • 1
    • 0023933332 scopus 로고
    • Performance tests of Doppler ultrasound equipment with a tissue and blood - Mimicking phantom
    • Boote E.J., Zagzebski J.A.: Performance tests of Doppler ultrasound equipment with a tissue and blood - mimicking phantom. J. Ultrasounds Med. 7: 137-148, 1988.
    • (1988) J. Ultrasounds Med. , vol.7 , pp. 137-148
    • Boote, E.J.1    Zagzebski, J.A.2
  • 3
    • 0037329071 scopus 로고    scopus 로고
    • Transrectal colour Doppler ultrasonography for quantifying angiogenesis in prostate cancer
    • Shigeno K., Igawa M., Shiina H., Kishi H., Urakami S.: Transrectal colour Doppler ultrasonography for quantifying angiogenesis in prostate cancer. B. J. U. International 91: 223-226, 2003.
    • (2003) B. J. U. International , vol.91 , pp. 223-226
    • Shigeno, K.1    Igawa, M.2    Shiina, H.3    Kishi, H.4    Urakami, S.5
  • 4
    • 0036211293 scopus 로고    scopus 로고
    • Association of colour Doppler vascularity index and microvessel density with survival in patients with gastric cancer
    • Chen C.N., Cheng Y.M., Lin M.T., Hsieh F.J., Lee P.H., Chang K.J.: Association of colour Doppler vascularity index and microvessel density with survival in patients with gastric cancer. Ann. Surg. 235(4): 512-518, 2002.
    • (2002) Ann. Surg. , vol.235 , Issue.4 , pp. 512-518
    • Chen, C.N.1    Cheng, Y.M.2    Lin, M.T.3    Hsieh, F.J.4    Lee, P.H.5    Chang, K.J.6
  • 5
    • 0034281486 scopus 로고    scopus 로고
    • Transcranial Doppler blood velocity measurement - The effect of change in velocity profile
    • Lunt M.L., Jenkinson D.F., Kerr D.: Transcranial Doppler blood velocity measurement - the effect of change in velocity profile. Ultrasound Med. Biol. 26(7): 1145-1151, 2000.
    • (2000) Ultrasound Med. Biol. , vol.26 , Issue.7 , pp. 1145-1151
    • Lunt, M.L.1    Jenkinson, D.F.2    Kerr, D.3
  • 9
    • 1042298885 scopus 로고    scopus 로고
    • Accuracy of spectral doppler flow and tissue velocity measurements in ultrasound systems
    • Walker A., Olsson E., Wranne B., Ringqvist I., Ask P. Accuracy of spectral doppler flow and tissue velocity measurements in ultrasound systems. Ultrasound in Med. & Biol. 30(1): 127-132, 2004.
    • (2004) Ultrasound in Med. & Biol. , vol.30 , Issue.1 , pp. 127-132
    • Walker, A.1    Olsson, E.2    Wranne, B.3    Ringqvist, I.4    Ask, P.5
  • 11
    • 10044277038 scopus 로고    scopus 로고
    • Validation of a sensitivity performance index test protocol and evaluation of colour Doppler sensitivity for a range of ultrasound scanners
    • Browne J.E., Watson A.J., Hosskins P., Elliot A.T.: Validation of a sensitivity performance index test protocol and evaluation of colour Doppler sensitivity for a range of ultrasound scanners. Ultrasound Med. Biol. 30(11): 1475-83, 2004.
    • (2004) Ultrasound Med. Biol. , vol.30 , Issue.11 , pp. 1475-1483
    • Browne, J.E.1    Watson, A.J.2    Hosskins, P.3    Elliot, A.T.4
  • 12
    • 0026734703 scopus 로고
    • Velocity evaluation phantom for colour and pulsed Doppler instruments
    • Rickey D.W., Rankin R., Fenster A.: Velocity evaluation phantom for colour and pulsed Doppler instruments. Ultrasound Med. Biol. 18: 479-494, 1992.
    • (1992) Ultrasound Med. Biol. , vol.18 , pp. 479-494
    • Rickey, D.W.1    Rankin, R.2    Fenster, A.3
  • 13
    • 0025108098 scopus 로고
    • Testing ultrasonic pulsed Doppler instruments with a physiologic string phantom
    • Philips D.J., Hossack J., Beach K.W, Strandness D.E. Jr.: Testing ultrasonic pulsed Doppler instruments with a physiologic string phantom. J. Ultrasound Med. 9: 429-436, 1990.
    • (1990) J. Ultrasound Med. , vol.9 , pp. 429-436
    • Philips, D.J.1    Hossack, J.2    Beach, K.W.3    Strandness Jr., D.E.4
  • 14
    • 0031814617 scopus 로고    scopus 로고
    • Dual time B-Mode ultrasound quality control test procedure. Report AAPM ultrasound task group No.1
    • Goodsitt M.M., Carson P.L., Witt S., Hykes D., Kofler J.M.: Dual time B-Mode ultrasound quality control test procedure. Report AAPM ultrasound task group No.1. Med. Phys. 25(8): 385-1406, 1998.
    • (1998) Med. Phys. , vol.25 , Issue.8 , pp. 385-1406
    • Goodsitt, M.M.1    Carson, P.L.2    Witt, S.3    Hykes, D.4    Kofler, J.M.5
  • 17
    • 0035021086 scopus 로고    scopus 로고
    • Effects of transducer, velocity, Doppler angle, and instrument setting on the accuracy of colour Doppler ultrasound
    • Stewart S.F.C.: Effects of transducer, velocity, Doppler angle, and instrument setting on the accuracy of colour Doppler ultrasound. Ultrasound Med. Biol. 27(4): 551-564, 2001.
    • (2001) Ultrasound Med. Biol. , vol.27 , Issue.4 , pp. 551-564
    • Stewart, S.F.C.1
  • 18
    • 0025125915 scopus 로고
    • Assurance of consistency Peack- velocity measurements with a variety of a Duplex Doppler Instruments
    • Kimme-Smith C., Hussain R., Duerinkx A., Tessler F., Grant E.: Assurance of consistency Peack- velocity measurements with a variety of a Duplex Doppler Instruments. Radiology 177(1): 265-272, 1990.
    • (1990) Radiology , vol.177 , Issue.1 , pp. 265-272
    • Kimme-Smith, C.1    Hussain, R.2    Duerinkx, A.3    Tessler, F.4    Grant, E.5
  • 19
    • 0003918484 scopus 로고    scopus 로고
    • National Council on Radiation Protection and Measurements Report No.99 Bethesda MD: NCRP 1988
    • National Council on Radiation Protection and Measurements Report No.99: Quality assurance for diagnostic imaging equipment. Bethesda MD: NCRP 1988.
    • Quality Assurance for Diagnostic Imaging Equipment
  • 20
    • 0026021204 scopus 로고
    • Performance tests of Doppler ultrasound equipment with a string phantom
    • b
    • Goldstein A. (b): Performance tests of Doppler ultrasound equipment with a string phantom. J. Ultrasound Med. 10: 125-139, 1991.
    • (1991) J. Ultrasound Med. , vol.10 , pp. 125-139
    • Goldstein, A.1
  • 21
    • 0025974741 scopus 로고
    • Effect of tank liquid acoustic velocity on Doppler string phantom measurement
    • a
    • Goldstein A. (a): Effect of tank liquid acoustic velocity on Doppler string phantom measurement. J. Ultrasound Med. 10: 141-148, 1991.
    • (1991) J. Ultrasound Med. , vol.10 , pp. 141-148
    • Goldstein, A.1
  • 22
    • 0034281588 scopus 로고    scopus 로고
    • The effect of acoustic velocity on phantom measurements
    • Goldstein A.: The effect of acoustic velocity on phantom measurements. Ultrasound Med. Biol. 26(7): 1133-1443, 2000.
    • (2000) Ultrasound Med. Biol. , vol.26 , Issue.7 , pp. 1133-1443
    • Goldstein, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.