메뉴 건너뛰기




Volumn 41, Issue 11, 2006, Pages 1053-1057

Validation of a hand-held exhaled nitric oxide analyzer for use in children

Author keywords

Asthma; Child; NIOX ; Nitric oxide; Reproducibility

Indexed keywords

NITRIC OXIDE;

EID: 33751033405     PISSN: 87556863     EISSN: 10990496     Source Type: Journal    
DOI: 10.1002/ppul.20491     Document Type: Article
Times cited : (56)

References (14)
  • 2
    • 14944353086 scopus 로고    scopus 로고
    • Exhaled nitric oxide predicts asthma relapse in children with clinical asthma remission
    • Pijnenburg MW, Hofhuis W, Hop WC, de Jongste JC. Exhaled nitric oxide predicts asthma relapse in children with clinical asthma remission. Thorax 2005;60:215-218.
    • (2005) Thorax , vol.60 , pp. 215-218
    • Pijnenburg, M.W.1    Hofhuis, W.2    Hop, W.C.3    De Jongste, J.C.4
  • 3
    • 17644363081 scopus 로고    scopus 로고
    • ATS/ERS recommendations for standardized procedures for the online and offline measurement of exhaled lower respiratory nitric oxide and nasal nitric oxide, 2005
    • ATS/ERS Recommendations for Standardized Procedures for the Online and Offline Measurement of Exhaled Lower Respiratory Nitric Oxide and Nasal Nitric Oxide, 2005. Am J Respir Crit Care Med 2005;171:912-930.
    • (2005) Am J Respir Crit Care Med , vol.171 , pp. 912-930
  • 4
    • 23244442847 scopus 로고    scopus 로고
    • Methodological issues related to exhaled nitric oxide measurement in children aged four to six years
    • Napier E, Turner SW. Methodological issues related to exhaled nitric oxide measurement in children aged four to six years. Pediatr Pulmonol 2005;204:97-104.
    • (2005) Pediatr Pulmonol , vol.204 , pp. 97-104
    • Napier, E.1    Turner, S.W.2
  • 5
    • 0038132095 scopus 로고    scopus 로고
    • Exhaled nitric oxide rather than lung function distinguishes preschool children with probable asthma
    • Malmberg LP, Pelkonen AS, Haahtela T, Turpeinen M. Exhaled nitric oxide rather than lung function distinguishes preschool children with probable asthma. Thorax 2003;58:494-499.
    • (2003) Thorax , vol.58 , pp. 494-499
    • Malmberg, L.P.1    Pelkonen, A.S.2    Haahtela, T.3    Turpeinen, M.4
  • 6
    • 7944232729 scopus 로고    scopus 로고
    • The Aerocrine exhaled nitric oxide monitoring system NIOX is cleared by the US Food and Drug Administration for monitoring therapy in asthma
    • Silkoff PE, Carlson M, Bourke T, Katial R, Ogren E, Szefler SJ. The Aerocrine exhaled nitric oxide monitoring system NIOX is cleared by the US Food and Drug Administration for monitoring therapy in asthma. J Allergy Clin Immunol 2004;114:1241-1256.
    • (2004) J Allergy Clin Immunol , vol.114 , pp. 1241-1256
    • Silkoff, P.E.1    Carlson, M.2    Bourke, T.3    Katial, R.4    Ogren, E.5    Szefler, S.J.6
  • 7
    • 4944260151 scopus 로고    scopus 로고
    • Effects of inhaled corticosteroids on exhaled leukotrienes and prostanoids in asthmatic children
    • Mondino C, G. C, Koch P, Pistelli R, Trove A, Barnes PJ, Montuschi P. Effects of inhaled corticosteroids on exhaled leukotrienes and prostanoids in asthmatic children. J Allergy Clin Immunol 2004;114:761-767.
    • (2004) J Allergy Clin Immunol , vol.114 , pp. 761-767
    • Mondino, C.1    Koch, P.2    Pistelli, R.3    Trove, A.4    Barnes, P.J.5    Montuschi, P.6
  • 8
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 33751056954 scopus 로고    scopus 로고
    • Accuracy and repeatability of a hand-held nitric oxide analyzer in adults with respiratory symptoms
    • Sovijärvi A, Järvinen H, Uusi-Simola J, Nikkinen P, Piirilä P. Accuracy and repeatability of a hand-held nitric oxide analyzer in adults with respiratory symptoms. Eur Respir J 2005; Suppl II.
    • (2005) Eur Respir J , Issue.SUPPL. II
    • Sovijärvi, A.1    Järvinen, H.2    Uusi-Simola, J.3    Nikkinen, P.4    Piirilä, P.5
  • 11
    • 33751050659 scopus 로고    scopus 로고
    • Novel hand-held device for exhaled nitric oxide analysis in research and clinical applications
    • Hemmingsson T, Linnarsson D, Gambert R. Novel hand-held device for exhaled nitric oxide analysis in research and clinical applications. Breath Gas Anal Med Diag 2004.
    • (2004) Breath Gas Anal Med Diag
    • Hemmingsson, T.1    Linnarsson, D.2    Gambert, R.3
  • 13
    • 0036314580 scopus 로고    scopus 로고
    • Nitric oxide in chronic airway inflammation in children: Diagnostic use and pathophysiological significance
    • Narang I, Ersu R, Wilson NM, Bush A. Nitric oxide in chronic airway inflammation in children: Diagnostic use and pathophysiological significance. Thorax 2002;57:586-589.
    • (2002) Thorax , vol.57 , pp. 586-589
    • Narang, I.1    Ersu, R.2    Wilson, N.M.3    Bush, A.4
  • 14
    • 0037339282 scopus 로고    scopus 로고
    • Reproducibility of exhaled nitric oxide measurements in healthy and asthmatic adults and children
    • Kharitonov SA, Gonio F, Kelly C, Meah S, Barnes PJ. Reproducibility of exhaled nitric oxide measurements in healthy and asthmatic adults and children. Eur Respir J 2003;21:433-438.
    • (2003) Eur Respir J , vol.21 , pp. 433-438
    • Kharitonov, S.A.1    Gonio, F.2    Kelly, C.3    Meah, S.4    Barnes, P.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.